Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera 601-S Water Hardness/Temperature Electrode for YD300 (AI4739) Water Hardness Electrode Apera Instruments
Apera 601-S Water Hardness/Temperature Electrode for YD300 (AI4739) Water Hardness Electrode Apera Instruments
Apera 601-S Water Hardness/Temperature Electrode for YD300 (AI4739) Water Hardness Electrode Apera Instruments
Apera 601-S Water Hardness/Temperature Electrode for YD300 (AI4739) Water Hardness Electrode Apera Instruments
Apera 601-S Water Hardness/Temperature Electrode for YD300 (AI4739) Water Hardness Electrode Apera Instruments
Apera 601-S Water Hardness/Temperature Electrode for YD300 (AI4739) Water Hardness Electrode Apera Instruments
Apera 601-S Water Hardness/Temperature Electrode for YD300 (AI4739) Water Hardness Electrode Apera Instruments
Apera 601-S Water Hardness/Temperature Electrode for YD300 (AI4739) Water Hardness Electrode Apera Instruments

Apera 601-S Water Hardness/Temperature Electrode for YD300 (AI4739)

$290.00

    Restore the sensing function of an Apera YD300 with the 601-S water-hardness electrode.

    • YD300 replacement: Designed for Apera’s water-hardness meter.
    • Three functions: Measuring, reference and temperature elements in one probe.
    • Hardness units: 1.5–1000 mg/L as CaCO₃ specified range.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / 601-S / AI4739

Keep your YD300 testing.
A replacement hardness/temperature electrode.

Restore the sensing function of an Apera YD300 with the 601-S water-hardness electrode. Its integrated measuring element, reference system and temperature sensor simplify hardness testing with the compatible meter.

Use with the YD300 and follow its calibration and sample-preparation instructions. The 15–40°C electrode range is the relevant sample-temperature limit.

Apera 601-S replacement electrode, from the supplied manufacturer photo resources.
Apera 601-S replacement electrode, from the supplied manufacturer photo resources. Tap or click the image for a larger view.
Choose the electrode and host-meter setupClick or tap to compare your optionsCompare below — click or tap here to close

Check the sensing method, connector and temperature requirements before ordering. A connector that fits does not by itself establish compatibility.

601-S product reference601-S8-pin · Water Hardness ElectrodeCurrent configuration
YD300 product referenceYD300Review the host meter and its replacement-electrode requirements.View product →

Linked cards open current store listings. Other cards compare configurations; they do not imply current storefront availability.

Know what you are ordering.

One 601-S water-hardness/temperature electrode. YD300 meter and calibration solutions are separate.

Ordering detail Configuration
Product 601-S
Manufacturer part number AI4739
Blue Tiger SKU BTS-AI4739
Order unit One replacement electrode
Apera 601-S sensing-tip close-up from the supplied photo archive.
Apera 601-S sensing-tip close-up from the supplied photo archive. Tap or click the image for a larger view.

See the sensing end.

The combination probe brings the measuring element, reference system and thermistor into one body. This close-up from Apera’s photo resources shows the sensing end without changing the product’s proportions.

Keep the sensing surfaces and reference junction in contact with the sample and follow the host meter’s preparation and calibration procedure.

Confirm the range
and host-meter match.

Use with the YD300 and follow its calibration and sample-preparation instructions. The 15–40°C electrode range is the relevant sample-temperature limit.

Specification Detail
Compatible meter Apera YD300
Hardness range 0.015–10 mmol/L; 1.5–1000 mg/L as CaCO₃
Temperature range 15–40°C / 59–104°F
Connector 8-pin
Thermistor 30 kΩ
Dimensions Ø12 × 160 mm
Apera 601-S manufacturer catalog specifications.
Apera 601-S manufacturer catalog specifications. Tap or click the image for a larger view.

Calibrate with the
specified meter procedure.

Use the YD300 hardness standards and sample procedure. The 601-S is a hardness electrode, not a calcium-only ISE.

Review YD300 hardness meter kit for the specified host setup.

Apera connector guide; the 8-pin format is shown for reference.
Apera connector guide; the 8-pin format is shown for reference. Tap or click the image for a larger view.

Check the 8-pin
connection before ordering.

Confirm the exact meter model and replacement part number. An 8-pin connection alone does not make every Apera electrode interchangeable.

Protect the connector and follow the meter/electrode care instructions after testing.

Check the specifications.

Use the complete Product Specifications tab to verify the measurement range, temperature limit, connector and order details against your application.

Compare related products.

YD300 water-hardness meter kit — the specified host 602 flexible electrode holder

601-S buyer questions

Which meter uses the 601-S?

Apera identifies it as the replacement electrode for the YD300 water-hardness meter.

What does the probe measure?

Water hardness with the YD300, using integrated measuring, reference and temperature elements.

What is its hardness range?

0.015–10 mmol/L, or 1.5–1000 mg/L expressed as CaCO₃.

What sample temperature is allowed?

15–40°C (59–104°F).

Which connector does it use?

An 8-pin connector; this does not make it universally compatible with all 8-pin meters.

Is it the same as a calcium-only ISE?

No. The YD300 hardness system and a calcium-specific ion electrode serve different measurement methods.

Are a meter and standards included?

No. This is the replacement electrode listing.

How do I prepare it for use?

Follow the YD300 instructions for electrode conditioning, calibration and sample testing before relying on results.

Confirm the exact configuration before ordering.

Review 601-S AI4739 against your measurement method, sample limits and host connection. Return to the price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Manufacturer part numberAI4739
    Blue Tiger SKUBTS-AI4739
    Model601-S
    Compatible meterApera YD300
    Hardness range0.015–10 mmol/L; 1.5–1000 mg/L as CaCO₃
    Temperature range15–40°C / 59–104°F
    Connector8-pin
    Thermistor30 kΩ
    DimensionsØ12 × 160 mm

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI4739
    Blue Tiger SKUBTS-AI4739
    Order unitOne 601-S replacement electrode
    Order contentsOne 601-S water-hardness/temperature electrode. YD300 meter and calibration solutions are separate.

    Manufacturer warranty coverage is subject to Apera’s terms for this exact product. Contact Blue Tiger Scientific for help confirming coverage or submitting a manufacturer warranty inquiry.

    For technical support, provide the manufacturer part number, meter model and a description of the issue. Blue Tiger Scientific can help coordinate product selection and manufacturer support.

    For a return request, contact Blue Tiger Scientific before sending the product back. Eligibility and any authorization requirements follow the applicable store return policy; manufacturer warranty service and store returns are separate processes.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat