Apera 5053 Food Salinity NaCl Tester Kit Default Title Food NaCl Salinity Tester Apera Instruments
Apera 5053 Food Salinity NaCl Tester Kit Food NaCl Salinity Tester Apera Instruments
Apera 5053 Food Salinity NaCl Tester Kit Food NaCl Salinity Tester Apera Instruments
Apera 5053 Food Salinity NaCl Tester Kit Default Title Food NaCl Salinity Tester Apera Instruments
Apera 5053 Food Salinity NaCl Tester Kit Food NaCl Salinity Tester Apera Instruments
Apera 5053 Food Salinity NaCl Tester Kit Food NaCl Salinity Tester Apera Instruments

Apera 5053 Food Salinity NaCl Tester Kit

$88.00

    A compact 0 to 20.0% NaCl-scale tester with one-point calibration and automatic temperature compensation.

    • NaCl weight-percentage scale; 0.1% display resolution
    • 50 mS/cm standard for one-point automatic calibration
    • Automatic compensation from 0 to 60°C; no temperature display
    • Two AAA batteries; no documented result memory or export

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / 5053 / AI237

Check liquid-food salinity.
Keep the NaCl scale in context.

5053 is a single-button salinity tester for soups, broths, sauces and other compatible liquid foods. Its platinum-black conductivity sensor reports a NaCl concentration scale from 0 to 20.0%. The kit includes 50 mS/cm calibration solution, two AAA alkaline batteries and a carrying case. It is not a pH, ORP or optical instrument.

Choose AI237 for routine recipe comparisons and high-concentration salt-solution checks, not a sodium-specific laboratory assay. The US manufacturer describes the result as sodium chloride weight percentage. In mixed foods, interpret the conductivity-derived result as NaCl-equivalent concentration rather than total salts or independently measured sodium.

Actual Apera 5053 yellow and red salinity tester with protective cap fitted
5053 reads a NaCl percentage scale. The photographed 0.0% is an illustration, not a sample result.
Which meter kit fits my measurement?Click or tap to compare all three compact configurationsClick or tap here to close the guide

Each card opens that model page. Match the supplied electrode and documented sample method. pH and conductivity-derived NaCl food salinity are different measurements. Match the parameter and meter format before comparing accessories; optional items are not supplied unless the exact kit list says so.

Choose the electrode for the sample.

One button, focused measurement

The front button handles power and calibration. Read the percentage on the LCD after stabilization; it does not simultaneously show temperature. Auto-off after ten minutes without operation and a low-battery indicator help manage portable use. The display photograph is illustrative, not a tested sample result.

Conductivity, not selective chemistry

Dissolved ions carry current through the sensing cell. The instrument expresses that response on a NaCl concentration scale. Other conductive ingredients can affect the result. Its platinum-black coating needs gentle treatment; a protected sensing head does not make the surface abrasion-proof.

A useful range with a source caveat

The current US page prints accuracy as ±0.4% without defining the basis. The official European 5053 manual instead prints ±2%FS ±one world. That wording is preserved, not silently corrected or combined into a new tolerance. Neither expression establishes performance for every food mixture.

Know what this configuration supplies.

Included item Order contents
5053 tester AI237 salinity configuration with protective electrode cap.
Calibration solution 50 mS/cm conductivity standard; supplied volume not specified.
Two AAA alkaline batteries Portable power supply listed in the US kit.
Carrying case Included for transport and storage.

Match the sample and preparation method.

Broth and soup comparisons

Compare representative liquid portions using the same recipe, sampling procedure and temperature conditions. Suspended solids, uneven mixing and fat layers can make readings unrepresentative. Establish a repeatable preparation method before using differences between batches to guide seasoning.

Sauces and aqueous brines

Use compatible water-based samples that wet the sensor properly. Oil-rich emulsions, thick residues and changing ionic ingredients require method checks. A reading cannot certify curing performance, food safety or the chemical composition of a brine. Use an appropriate reference assay when those decisions matter.

Original 5053 manual calibration instructions with CAL LCD symbol
Use 50.0 mS/cm standard. Rinse, stir and wait for repeatable readings; hold the button about two seconds for CAL and the flashing 50.0 mS indication. No 12.88 mS/cm substitution.

Calibrate with 50 mS/cm.
Then measure a stable sample.

Prepare the supplied two AAA batteries with correct polarity, remove the electrode cap and inspect the sensing end. Rinse with pure water and shake off excess water. Use a clean portion of the specified 50.0 mS/cm conductivity standard; do not substitute 12.88 mS/cm or an assumed percentage salinity solution.

The exact 5053 manual directs the operator to immerse, stir and then leave the probe still until the standard reading is repeatable. Hold the button for about two seconds until CAL appears and 50.0 mS flashes. Calibration completes after several seconds. The mS indication belongs to calibration, not a documented selectable conductivity measurement mode.

Rinse again, shake off excess water, immerse in the sample, stir gently and allow the reading to settle. Automatic compensation covers 0 to 60°C, but does not eliminate thermal equilibration. Cool hotter food samples before testing and use a separate thermometer. Do not promise a fixed ten-second result in every mixture.

Understand the sensing end and probe housing.

Manufacturer photograph of the uncapped 5053 conductivity sensing head
Conductivity sensing is expressed on a NaCl scale. Other ions in mixed foods can influence the reading.

Rinse between samples.
Do not wipe the platinum-black surface.

The exact manual requires pure-water rinsing before measurement and after use, followed by shaking off water and replacing the cap. Carryover from concentrated samples can distort the next reading. Keep the sensing area clear of trapped material without scraping or polishing it.

For a stained electrode, the manual permits warm water with detergent or alcohol and explicitly says not to wipe the coating. Rinse away cleaning residues and verify calibration before returning to work. This cleaning guidance is not a validated food-contact sanitation procedure or permission to use arbitrary solvents.

IP57 is the published enclosure rating, not authorization for dishwasher cleaning, steam sterilization or unrestricted chemical exposure. No exact replacement-probe part or user replacement procedure was located. Confirm service options for 5053 specifically rather than assuming that probes from other Apera testers fit.

Close detail of the two dark sensing elements inside the yellow protective guard
Protect the platinum-black coating. Rinse away residues; do not wipe, scrape or polish the sensing surfaces.
Original 5053 manual instruction to clean stains without wiping the platinum-black coating
The exact manual permits warm water with detergent or alcohol for stains and warns against wiping the coating. Rinse thoroughly afterward. This is not a validated sanitation procedure.
5053 LCD percentage symbol and single power CAL button
The LCD shows salinity percent, not temperature. One button operates power and calibration.
Original manual ten-minute auto-off instruction and battery warning LCD symbol
Automatic shutdown follows ten minutes without operation. Replace the two AAA batteries when the low-battery symbol appears.

Read the scale. Check calibration.

Use the controls only for the measurement and calibration functions documented for this exact tester. Check the displayed value, unit and any documented calibration indicator before assigning a result to a sample. Screen values in photographs are illustrative, not sample results. The model-specific record and output workflow is explained below.

Follow the exact parameter-specific calibration procedure, using the required standard, solution or calibration atmosphere. Temperature compensation does not make different sample temperatures, preparation methods or chemistry equivalent. Follow the model-specific meter and electrode instructions before extending the method to a new sample.

Read locally.
Record the sample context yourself.

Result memory and computer export are not documented for 5053. Write down the reading, sample identity, preparation, separate temperature measurement and calibration check. The 0.1% display increment is resolution, not a guarantee that every difference of that size is significant.

Weight percentage means grams of NaCl per 100 grams of solution for the stated NaCl basis. In mixed foods, the displayed equivalent is not a direct weighing of dissolved solids. Do not relabel it as marine ppt, TDS or dietary sodium.

Original 5053 manual technical-parameter excerpt showing range, resolution and accuracy wording
Original manual: 0 to 20.0%, resolution 0.1%, accuracy “±2%FS ±one world.” The US page separately prints ±0.4% without defining its basis. These are not silently reconciled.

Compare another pocket-testing workflow.

Related workflow: Apera Salt20 Pocket Salinity Tester Kit (AI214). Salt20 is a separate low-salinity water tester, not an equivalent high-concentration NaCl food meter. Its units, range and intended sample conditions differ. Compare the exact supplied sensors, measurement parameter, accessories and data features rather than assuming similar model names mean identical kits.

5053 buyer questions

Does it measure sodium, pH or ORP?

No. It reports a conductivity-derived NaCl salinity scale. It is not sodium-selective and does not provide pH, ORP or optical refractometry.

What range and resolution are specified?

The exact 5053 manual gives 0 to 20.0% with 0.1% resolution. The current US description identifies weight percentage for sodium chloride solutions.

Does ±0.4% mean relative accuracy?

The current US page does not define it as relative error, percentage points or full-scale error. Do not assume a basis. The European exact-model manual uses different wording: ±2%FS ±one world.

Which calibration solution comes with AI237?

The current US kit lists 50 mS/cm calibration solution. Bottle volume is not specified there. One-point calibration uses that conductivity standard, not 12.88 mS/cm.

Does automatic compensation display temperature?

No. Compensation is automatic from 0 to 60°C, and the manual explicitly states no temperature display. A separate thermometer is needed to record sample temperature.

Can I save readings or replace the probe?

No result-memory or export workflow is documented. A user-replaceable probe and compatible replacement part were not verified; seek model-specific service advice before purchase if replacement is essential.

How often should I calibrate?

The manual suggests every one to two months under normal conditions and says the meter is factory calibrated. Food residues and demanding comparisons justify additional checks; verify after cleaning or suspect readings.

What warranty applies?

The current US policy provides two years for the instrument and six months for the probe from delivery, for qualifying defects in materials or workmanship, with repair or replacement at Apera's option. Exclusions include accidental damage, improper use, normal wear, transportation, storage, failure to follow instructions, unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter, unauthorized repair, and external causes including abuse or events beyond Apera's reasonable control. This is not a service-life guarantee.

Confirm the exact configuration before ordering.

Review 5053 AI237 against the sample, supplied electrode and documented method. Return to the live price and ordering controls when the configuration fits your work.

Back to price and ordering ↑
    SpecificationDetail
    Model / SKU5053 / AI237
    MeasurementNaCl salinity percentage; conductivity-derived
    Range / resolution0 to 20.0% / 0.1%
    Accuracy, current US page±0.4%; basis not defined
    Accuracy, European manual±2%FS ±one world; original wording
    CalibrationOne point, automatic; 50.0 mS/cm
    Temperature compensationAutomatic, 0 to 60°C; no temperature display
    SensorPlatinum-black conductivity sensing surface
    Power / battery life2 × AAA; manual states over 100 continuous hours
    Auto-off / low battery10 minutes without operation / LCD indicator
    Memory / exportN/A; no documented storage or export
    EnclosureIP57
    Dimensions / instrument weight39 × 25 × 176 mm / 87 g; not shipping weight
    Limited warranty2 years instrument; 6 months probe, from delivery; exclusions apply

    Ordering Information

    Ordering detailConfiguration
    Manufacturer catalogAI237
    Blue Tiger SKUBTS-AI237
    Order unit1 exact listed meter-kit configuration
    Order contents5053 tester: AI237 salinity configuration with protective electrode cap.; Calibration solution: 50 mS/cm conductivity standard; supplied volume not specified.; Two AAA alkaline batteries: Portable power supply listed in the US kit.; Carrying case: Included for transport and storage.

    Apera Manufacturer Limited Warranty

    The current US policy provides two years for the instrument and six months for the probe from delivery, for qualifying defects in materials or workmanship, with repair or replacement at Apera's option. Exclusions include accidental damage, improper use, normal wear, transportation, storage, failure to follow instructions, unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter, unauthorized repair, and external causes including abuse or events beyond Apera's reasonable control. This is not a service-life guarantee.

    Keep the exact product and purchase details when requesting service. Follow the stated model-specific warranty conditions and product instructions; the instrument and supplied sensors or consumables can have different coverage terms.

    5053 official documents

    Use the meter and electrode documents for their stated model and scope. Regional editions are labeled where supplied; software, probe and packing details can differ between revisions. Check the supplied instrument markings when sources describe different hardware revisions. Each card opens a verified manufacturer PDF in a new tab.

Questions about a product? Ask us here.