Skip to content
Anchor Molecular DNA-Depleted Plasma: representative manufacturer photo showing 100 mL bottles, catalog 60601003; order quantity follows selected format
Anchor Molecular DNA-Depleted EDTA Human Plasma Research Plasma Matrix Anchor Molecular
Anchor Molecular DNA-Depleted EDTA Human Plasma Research Plasma Matrix Anchor Molecular
Anchor Molecular DNA-Depleted Plasma: representative manufacturer photo showing 100 mL bottles, catalog 60601003; order quantity follows selected format
Anchor Molecular DNA-Depleted EDTA Human Plasma Research Plasma Matrix Anchor Molecular
Anchor Molecular DNA-Depleted EDTA Human Plasma Research Plasma Matrix Anchor Molecular

Anchor Molecular DNA-Depleted EDTA Human Plasma

$824.00

    Build research controls in a human plasma matrix—not just buffer. Anchor Molecular DNA-Depleted EDTA Plasma reduces endogenous DNA while retaining a complex plasma background for study-specific reference materials.

    • Typical DNA <20 pg/mL for a low-background research matrix
    • Choose 50–1,000 mL or a 40 × 5 mL vial pack
    • Human EDTA plasma • For in vitro research use only

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Order Now
FIND YOUR FIT

Choose Your DNA-Depleted Plasma Format

Compare configurations below. Each quantity is one pack or case as listed—not one individual item.

Available configurations for Anchor Molecular DNA-Depleted EDTA Human Plasma
Product Catalog No. Configuration Pack / Case Price Order
60601001 BTS-60601001 DNA-Depleted EDTA Plasma — 1,000 mL 1,000 mL total $824.00 per listed pack / case

60601002 BTS-60601002 DNA-Depleted EDTA Plasma — 500 mL 500 mL total $515.00 per listed pack / case

60601003 BTS-60601003 DNA-Depleted EDTA Plasma — 100 mL 100 mL total $206.00 per listed pack / case

60601004 BTS-60601004 DNA-Depleted EDTA Plasma — 50 mL 50 mL total $144.20 per listed pack / case

60601005 BTS-60601005 DNA-Depleted EDTA Plasma — 40 × 5 mL vials 40 vials × 5 mL; 200 mL total $618.00 per listed pack / case

ANCHOR MOLECULAR · RESEARCH MATRICES

Build your controls.
Keep the plasma background.

Move beyond a buffer-only starting point. Anchor Molecular DNA-Depleted EDTA Plasma provides a human-plasma base for preparing your own research reference materials—with reduced endogenous DNA and retained matrix components.

Less background DNA

Typical DNA specification: <20 pg/mL, for a low-background starting matrix.

Human EDTA plasma

Pooled human-plasma matrix, rather than buffer or a synthetic plasma substitute.

Five orderable formats

Four bulk volumes plus forty 5 mL vials. Choose the supplied format in the ordering chart.

The matrix is part of the test.

Adding DNA to buffer and adding DNA to plasma are not the same starting point. Proteins, lipids and other plasma components can influence an extraction workflow. A DNA-depleted plasma matrix lets you introduce your material of interest while working in a human-plasma background.

Conceptual illustration: added DNA in a simpler buffer background

Buffer offers a simpler background.

Conceptual illustration: added DNA among retained plasma proteins and lipids

DNA-depleted plasma retains a complex human-plasma background.

Illustrations explain the concept only: blue = added DNA, gold = proteins, green = lipids. Not measured data, not to scale; the number of symbols does not represent composition or concentration.

DNA depletion does not mean a stripped-down matrix.

The point is not simply to remove background DNA. It is to work with a plasma background that still contains other naturally occurring material. Anchor’s microscopy comparison shows structures it identifies as exosomes and non-exosomal vesicles or aggregates in both normal and DNA-depleted plasma.

Normal plasma

Anchor Molecular slide3 normal plasma micrographs: upper exosome panel, lower non-exosomal vesicle or aggregate panel; original scale bars retained
Normal plasma: the manufacturer labels the upper panel as exosomes and the lower panel as non-exosomal vesicles/aggregates. Scale bars are retained.

DNA-depleted plasma

Anchor Molecular slide3 DNA-depleted plasma micrographs: upper exosome panel, lower non-exosomal vesicle or aggregate panel; original scale bars retained
DNA-depleted plasma: the same upper/lower panel categories, with original scale bars retained. Images support a qualitative comparison, not a guaranteed particle count.

Manufacturer microscopy, presentation slide 3. Original image panels are shown with permission. These images do not establish a lot-specific exosome concentration or universal equivalence for every application.

Your spike-in material changes the question.

A synthetic DNA spike and a fragmented genomic-DNA preparation need not behave identically during extraction. Anchor’s study compares both across buffer, synthetic plasma, plasma and DNA-depleted plasma.

The pattern changes between the two types of input material. When planning a research control, consider both the matrix and the kind of DNA you introduce—not just the nominal starting concentration.

Anchor Molecular presentation slide9: original percent-recovery chart for synthetic DNA and gDNA fragments in four matrices
Anchor Molecular presentation, slide 9. Original percent-recovery chart, including error bars. Left group: synthetic DNA; right group: gDNA fragments. This experiment is not a universal recovery specification.
Anchor Molecular presentation slide10: original standard-deviation versus allele-frequency chart for four matrices
Anchor Molecular presentation, slide 10. AF% = allele frequency; SD = standard deviation. “Patient” denotes the presentation’s patient-plasma condition and “DD Plasma” denotes DNA-depleted plasma. Original curves and points retained.

Look beyond yield to repeatability.

For a low-level research assay, average recovery is only one part of the picture. Variation between replicates matters too. Anchor’s example plots the standard deviation of calculated allele frequency against allele frequency for four matrix conditions.

Plasma and DNA-depleted plasma show greater variation than buffer at the displayed levels. A simpler buffer background can therefore give a different view of assay behavior. Use a matrix suited to the research question, then establish acceptance criteria in your own workflow.

These are manufacturer study results, not guaranteed precision, sensitivity or detection limits for this product.

Put the matrix to work in your research.

01 / PREPARE

Build your own reference materials

Introduce your own high-positive research material into a plasma base to prepare study-specific controls, rather than relying on buffer alone.

02 / EXTRACT

Evaluate the extraction step

Use a plasma background when studying how your workflow handles a complex matrix. Confirm suitability for your target, extraction method and detection system.

03 / EVALUATE

Study low-level DNA detection

Reduced endogenous DNA provides a useful starting matrix for cfDNA and ctDNA assay-development research. It is not a pre-assigned positive control.

See why the background matters.

In the manufacturer’s example, equal amounts of ctDNA fragments were serially spiked into four matrices: TE buffer, synthetic plasma, patient plasma and DNA-depleted plasma. Extracted ctDNA was then quantified by qPCR.

The curves differ by matrix. That is the buying insight: a buffer-based result may not describe how the same workflow behaves in plasma.

Read this as a matrix comparison—not a product-quality ranking. The figure describes one manufacturer experiment, not guaranteed recovery, patient-sample equivalence or universal assay performance.

Anchor Molecular original Figure 1 showing extracted copy per mL versus spiked copy per mL in four matrices

Manufacturer data: “Matrix Effect of ctDNA Extraction,” reproduced from the DNA-Depleted Plasma brochure. Axes and plotted data are unchanged.

Read the trace—not just the total fluorescence.

Anchor’s Figure A compares DNA-fragment fluorescence profiles in buffer and plasma. The prominent short-fragment peaks are similar, while the plasma trace shows more signal across the higher-size region. The practical lesson is that the surrounding matrix deserves attention—not just the main peak.

RFU is a fluorescence signal, not a direct statement of genomic DNA mass. Anchor’s later analytical memo reports protein-related high-molecular-weight signals after bead-based cfDNA extraction. Read these sources together: a higher-size feature is not, by itself, proof of residual DNA.

Original manufacturer Figure A: buffer in blue and plasma in red; RFU versus DNA size
Manufacturer Figure A, supplied image. Blue: buffer. Red: plasma. Original axes and traces retained; this is an example, not a lot-specific COA or a guaranteed performance result.

Choose the format around your bench—not just the volume.

Four bulk-volume choices

Select 50, 100, 500 or 1,000 mL for the total volume your study needs. These are listed volume formats; do not assume a specific bottle count.

Forty separate 5 mL vials

Catalog 60601005 supplies 40 × 5 mL: 200 mL total. Consider this presentation when separate small containers suit your handling plan.

One order quantity is one listed format. For example, quantity 1 of 60601005 means forty 5 mL vials—not one vial. The live ordering chart above identifies each catalog number and its supplied quantity.

Know what is in the matrix. Know what is in the signal.

Product characterization

The insert lists typical DNA, protein, immunoglobulin, lipid and pH characteristics. See the Specifications tab for the insert’s values, kept separate from lot-specific results.

A lot-specific certificate

The manufacturer states that the order’s COA is enclosed in the shipping package. The downloadable example is lot 240636 only; it is not the certificate for a future shipment.

A practical analytical detail: Anchor’s research memo investigates a high-molecular-weight feature seen after bead-based cfDNA extraction. In the experiments described, the feature persisted after DNase treatment but was removed by proteinase K, supporting a protein-related contribution to the observed signal.

If you use fluorescence-based DNA quantification, account for workflow-specific interference rather than interpreting every signal as residual DNA. Review the memo with your method-development team; it is not a universal treatment protocol.

Plan for cold storage and responsible handling.

This is human-derived laboratory material. Treat it as potentially biohazardous, even when donor-screening results are negative, and use the controls required by your laboratory’s risk assessment.

Keep the applicable label, product insert, SDS and lot COA with your study records. The SDS specifies frozen storage for unopened bottles and refrigerated handling after opening; follow the current supplied instructions and lot expiration. The insert identifies blue-ice shipment, not a guaranteed dispatch or delivery time.

The SDS lists sodium azide in a 0–0.05% range. Check the applicable product documentation when assessing formulation compatibility and waste disposal. For in vitro research use only—not for diagnostic or therapeutic use.

Round out the research workflow.

Organize research aliquots with MTC Bio cryogenic vials and keep samples organized with MTC Bio freezer boxes. These are related workflow supplies, sold separately—not included with this plasma or validated as part of Anchor’s assay data.

Need a different background-DNA level?

Anchor lists customized plasma and less-processed material with higher background DNA as options available on request. Ask Blue Tiger Scientific about your research requirements. Those alternatives are separate from the five standard DNA-depleted formats shown here and require confirmation of specification and availability.

Frequently Asked Questions

What is DNA-depleted EDTA plasma?

It is a pooled human-plasma matrix processed to reduce endogenous DNA while retaining other plasma components. Anchor Molecular supplies it for in vitro research applications, including preparation of study-specific reference materials.

Is DNA-depleted plasma completely DNA-free?

No absolute-zero claim is made. The manufacturer’s product insert gives a typical DNA value below 20 pg/mL. The SDS also notes trace unencapsulated DNA; suitability depends on your target and method.

Why choose a plasma matrix rather than buffer?

Buffer is a simpler background. Human plasma contains proteins, lipids and other components that can affect extraction and downstream measurement. Anchor’s brochure shows matrix-dependent ctDNA extraction in its example experiment; it does not establish universal equivalence to patient samples.

What is included in catalog 60601005?

One listed pack contains forty 5 mL vials of DNA-depleted plasma, totaling 200 mL. An order quantity of one means one 40-vial pack. The 50, 100, 500 and 1,000 mL formats are separate catalog numbers.

Does the bottle photograph show exactly what I receive?

The photograph shows representative Anchor Molecular DNA-Depleted Plasma bottles labeled 100 mL, catalog 60601003. It illustrates the product, not a three-bottle order. Your supplied volume and vial count follow the catalog number selected in the ordering chart.

Will I receive a certificate of analysis?

Anchor states that the COA for the order is enclosed in the shipping package. The downloadable sample is for lot 240636 and must not be treated as the certificate for every shipment. Its reported RNaseP qPCR gDNA result is lot-specific.

How should DNA-depleted plasma be stored and handled?

Follow the current supplied label, lot COA, product insert and SDS. The SDS states unopened bottles are stored at −20°C or below and opened bottles are stable up to 30 days at 2–8°C. The insert and sample COA also describe refrigerated use storage; confirm the instructions applicable to your lot. Treat all human-derived material as potentially biohazardous.

Is this a ready-to-use diagnostic control or a positive DNA standard?

No. It is a research-use plasma matrix, not a diagnostic product or an assigned positive DNA standard. Any spike-in material, target concentration, extraction method and acceptance criteria must be established for the laboratory’s research workflow.

    Product Specifications

    PropertyValue
    BrandAnchor Molecular
    ProductDNA-Depleted EDTA Plasma
    MatrixPooled human plasma
    Typical DNA<20 pg/mL
    Total protein4–7 g/dL
    IgG300–1700 mg/dL
    IgA70–400 mg/dL
    IgM10–172 mg/dL
    Cholesterol30–199 mg/dL
    Triglycerides30–149 mg/dL
    HDL>10 mg/dL
    VLDL10–40 mg/dL
    LDL20–99 mg/dL
    pH7.2–7.6
    Manufacturer shipping conditionBlue ice, per product insert; delivery timing is not specified
    Storage and expiryFollow current supplied label and lot documents; refer to handling guidance and SDS
    Intended useFor in vitro research use only

    Typical biochemical values above follow the manufacturer’s product insert. IgG, IgA and IgM refer to immunoglobulins G, A and M; HDL, VLDL and LDL refer to the respective cholesterol fractions. Use the current lot COA for lot-specific results.

    Ordering Information

    Cat. No.Supplied Format
    606010011,000 mL volume format
    60601002500 mL volume format
    60601003100 mL volume format
    6060100450 mL volume format
    6060100540 × 5 mL vials; 200 mL total per pack

    Research use and handling

    For in vitro research use only. This human-derived material must be handled as potentially biohazardous by personnel trained in laboratory techniques. Follow the current product label, SDS, product insert and lot-specific certificate of analysis.

    Storage, shipment and documentation

    The manufacturer identifies blue-ice shipment in its product insert. Storage and remaining shelf life depend on the supplied lot and its instructions. Contact Blue Tiger Scientific before ordering if your study requires particular lot documentation, remaining shelf life or delivery arrangements. No guaranteed transit or dispatch time is stated here.

    Order questions and returns

    Contact Blue Tiger Scientific for order questions or to request assistance with a product concern. Do not return biological material without prior authorization and shipping instructions. Blue Tiger Scientific will coordinate manufacturer-related technical and quality questions with Anchor Molecular.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Anchor Molecular DNA-Depleted EDTA Human Plasma

Format: 1,000 mL
Authorized Dealer

ANCHOR MOLECULAR · RESEARCH MATRICES

Build your controls.
Keep the plasma background.

Move beyond a buffer-only starting point. Anchor Molecular DNA-Depleted EDTA Plasma provides a human-plasma base for preparing your own research reference materials—with reduced endogenous DNA and retained matrix components.

Less background DNA

Typical DNA specification: <20 pg/mL, for a low-background starting matrix.

Human EDTA plasma

Pooled human-plasma matrix, rather than buffer or a synthetic plasma substitute.

Five orderable formats

Four bulk volumes plus forty 5 mL vials. Choose the supplied format in the ordering chart.

The matrix is part of the test.

Adding DNA to buffer and adding DNA to plasma are not the same starting point. Proteins, lipids and other plasma components can influence an extraction workflow. A DNA-depleted plasma matrix lets you introduce your material of interest while working in a human-plasma background.

Conceptual illustration: added DNA in a simpler buffer background

Buffer offers a simpler background.

Conceptual illustration: added DNA among retained plasma proteins and lipids

DNA-depleted plasma retains a complex human-plasma background.

Illustrations explain the concept only: blue = added DNA, gold = proteins, green = lipids. Not measured data, not to scale; the number of symbols does not represent composition or concentration.

DNA depletion does not mean a stripped-down matrix.

The point is not simply to remove background DNA. It is to work with a plasma background that still contains other naturally occurring material. Anchor’s microscopy comparison shows structures it identifies as exosomes and non-exosomal vesicles or aggregates in both normal and DNA-depleted plasma.

Normal plasma

Anchor Molecular slide3 normal plasma micrographs: upper exosome panel, lower non-exosomal vesicle or aggregate panel; original scale bars retained
Normal plasma: the manufacturer labels the upper panel as exosomes and the lower panel as non-exosomal vesicles/aggregates. Scale bars are retained.

DNA-depleted plasma

Anchor Molecular slide3 DNA-depleted plasma micrographs: upper exosome panel, lower non-exosomal vesicle or aggregate panel; original scale bars retained
DNA-depleted plasma: the same upper/lower panel categories, with original scale bars retained. Images support a qualitative comparison, not a guaranteed particle count.

Manufacturer microscopy, presentation slide 3. Original image panels are shown with permission. These images do not establish a lot-specific exosome concentration or universal equivalence for every application.

Your spike-in material changes the question.

A synthetic DNA spike and a fragmented genomic-DNA preparation need not behave identically during extraction. Anchor’s study compares both across buffer, synthetic plasma, plasma and DNA-depleted plasma.

The pattern changes between the two types of input material. When planning a research control, consider both the matrix and the kind of DNA you introduce—not just the nominal starting concentration.

Anchor Molecular presentation slide9: original percent-recovery chart for synthetic DNA and gDNA fragments in four matrices
Anchor Molecular presentation, slide 9. Original percent-recovery chart, including error bars. Left group: synthetic DNA; right group: gDNA fragments. This experiment is not a universal recovery specification.
Anchor Molecular presentation slide10: original standard-deviation versus allele-frequency chart for four matrices
Anchor Molecular presentation, slide 10. AF% = allele frequency; SD = standard deviation. “Patient” denotes the presentation’s patient-plasma condition and “DD Plasma” denotes DNA-depleted plasma. Original curves and points retained.

Look beyond yield to repeatability.

For a low-level research assay, average recovery is only one part of the picture. Variation between replicates matters too. Anchor’s example plots the standard deviation of calculated allele frequency against allele frequency for four matrix conditions.

Plasma and DNA-depleted plasma show greater variation than buffer at the displayed levels. A simpler buffer background can therefore give a different view of assay behavior. Use a matrix suited to the research question, then establish acceptance criteria in your own workflow.

These are manufacturer study results, not guaranteed precision, sensitivity or detection limits for this product.

Put the matrix to work in your research.

01 / PREPARE

Build your own reference materials

Introduce your own high-positive research material into a plasma base to prepare study-specific controls, rather than relying on buffer alone.

02 / EXTRACT

Evaluate the extraction step

Use a plasma background when studying how your workflow handles a complex matrix. Confirm suitability for your target, extraction method and detection system.

03 / EVALUATE

Study low-level DNA detection

Reduced endogenous DNA provides a useful starting matrix for cfDNA and ctDNA assay-development research. It is not a pre-assigned positive control.

See why the background matters.

In the manufacturer’s example, equal amounts of ctDNA fragments were serially spiked into four matrices: TE buffer, synthetic plasma, patient plasma and DNA-depleted plasma. Extracted ctDNA was then quantified by qPCR.

The curves differ by matrix. That is the buying insight: a buffer-based result may not describe how the same workflow behaves in plasma.

Read this as a matrix comparison—not a product-quality ranking. The figure describes one manufacturer experiment, not guaranteed recovery, patient-sample equivalence or universal assay performance.

Anchor Molecular original Figure 1 showing extracted copy per mL versus spiked copy per mL in four matrices

Manufacturer data: “Matrix Effect of ctDNA Extraction,” reproduced from the DNA-Depleted Plasma brochure. Axes and plotted data are unchanged.

Read the trace—not just the total fluorescence.

Anchor’s Figure A compares DNA-fragment fluorescence profiles in buffer and plasma. The prominent short-fragment peaks are similar, while the plasma trace shows more signal across the higher-size region. The practical lesson is that the surrounding matrix deserves attention—not just the main peak.

RFU is a fluorescence signal, not a direct statement of genomic DNA mass. Anchor’s later analytical memo reports protein-related high-molecular-weight signals after bead-based cfDNA extraction. Read these sources together: a higher-size feature is not, by itself, proof of residual DNA.

Original manufacturer Figure A: buffer in blue and plasma in red; RFU versus DNA size
Manufacturer Figure A, supplied image. Blue: buffer. Red: plasma. Original axes and traces retained; this is an example, not a lot-specific COA or a guaranteed performance result.

Choose the format around your bench—not just the volume.

Four bulk-volume choices

Select 50, 100, 500 or 1,000 mL for the total volume your study needs. These are listed volume formats; do not assume a specific bottle count.

Forty separate 5 mL vials

Catalog 60601005 supplies 40 × 5 mL: 200 mL total. Consider this presentation when separate small containers suit your handling plan.

One order quantity is one listed format. For example, quantity 1 of 60601005 means forty 5 mL vials—not one vial. The live ordering chart above identifies each catalog number and its supplied quantity.

Know what is in the matrix. Know what is in the signal.

Product characterization

The insert lists typical DNA, protein, immunoglobulin, lipid and pH characteristics. See the Specifications tab for the insert’s values, kept separate from lot-specific results.

A lot-specific certificate

The manufacturer states that the order’s COA is enclosed in the shipping package. The downloadable example is lot 240636 only; it is not the certificate for a future shipment.

A practical analytical detail: Anchor’s research memo investigates a high-molecular-weight feature seen after bead-based cfDNA extraction. In the experiments described, the feature persisted after DNase treatment but was removed by proteinase K, supporting a protein-related contribution to the observed signal.

If you use fluorescence-based DNA quantification, account for workflow-specific interference rather than interpreting every signal as residual DNA. Review the memo with your method-development team; it is not a universal treatment protocol.

Plan for cold storage and responsible handling.

This is human-derived laboratory material. Treat it as potentially biohazardous, even when donor-screening results are negative, and use the controls required by your laboratory’s risk assessment.

Keep the applicable label, product insert, SDS and lot COA with your study records. The SDS specifies frozen storage for unopened bottles and refrigerated handling after opening; follow the current supplied instructions and lot expiration. The insert identifies blue-ice shipment, not a guaranteed dispatch or delivery time.

The SDS lists sodium azide in a 0–0.05% range. Check the applicable product documentation when assessing formulation compatibility and waste disposal. For in vitro research use only—not for diagnostic or therapeutic use.

Round out the research workflow.

Organize research aliquots with MTC Bio cryogenic vials and keep samples organized with MTC Bio freezer boxes. These are related workflow supplies, sold separately—not included with this plasma or validated as part of Anchor’s assay data.

Need a different background-DNA level?

Anchor lists customized plasma and less-processed material with higher background DNA as options available on request. Ask Blue Tiger Scientific about your research requirements. Those alternatives are separate from the five standard DNA-depleted formats shown here and require confirmation of specification and availability.

Frequently Asked Questions

What is DNA-depleted EDTA plasma?

It is a pooled human-plasma matrix processed to reduce endogenous DNA while retaining other plasma components. Anchor Molecular supplies it for in vitro research applications, including preparation of study-specific reference materials.

Is DNA-depleted plasma completely DNA-free?

No absolute-zero claim is made. The manufacturer’s product insert gives a typical DNA value below 20 pg/mL. The SDS also notes trace unencapsulated DNA; suitability depends on your target and method.

Why choose a plasma matrix rather than buffer?

Buffer is a simpler background. Human plasma contains proteins, lipids and other components that can affect extraction and downstream measurement. Anchor’s brochure shows matrix-dependent ctDNA extraction in its example experiment; it does not establish universal equivalence to patient samples.

What is included in catalog 60601005?

One listed pack contains forty 5 mL vials of DNA-depleted plasma, totaling 200 mL. An order quantity of one means one 40-vial pack. The 50, 100, 500 and 1,000 mL formats are separate catalog numbers.

Does the bottle photograph show exactly what I receive?

The photograph shows representative Anchor Molecular DNA-Depleted Plasma bottles labeled 100 mL, catalog 60601003. It illustrates the product, not a three-bottle order. Your supplied volume and vial count follow the catalog number selected in the ordering chart.

Will I receive a certificate of analysis?

Anchor states that the COA for the order is enclosed in the shipping package. The downloadable sample is for lot 240636 and must not be treated as the certificate for every shipment. Its reported RNaseP qPCR gDNA result is lot-specific.

How should DNA-depleted plasma be stored and handled?

Follow the current supplied label, lot COA, product insert and SDS. The SDS states unopened bottles are stored at −20°C or below and opened bottles are stable up to 30 days at 2–8°C. The insert and sample COA also describe refrigerated use storage; confirm the instructions applicable to your lot. Treat all human-derived material as potentially biohazardous.

Is this a ready-to-use diagnostic control or a positive DNA standard?

No. It is a research-use plasma matrix, not a diagnostic product or an assigned positive DNA standard. Any spike-in material, target concentration, extraction method and acceptance criteria must be established for the laboratory’s research workflow.

Use this text to share information about your product.

Use this text to share information about your product.

Use this text to share information about your product.