$4,400.00

    Please note: This product is made to order, and may carry up to 3-6 weeks lead times.

    The AirClean® Systems upflow microscope enclosure protects the operator from gases, fumes or particulate with bonded carbon or HEPA filtration. AirSafe™ automatic safety controller constantly monitors filter and airflow conditions and allows one-touch control of all enclosure features. This configuration does not provide process protection.

See All Specs

Featuring the AirSafe® Automatic Safety Controller

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Engineered for ultimate safety and convenience, the AirClean® Operator Protection Microscope Enclosure provides a controlled environment for delicate procedures. Constructed from durable materials, this enclosure features the advanced AirSafe™ automatic safety controller, ensuring the highest level of operator protection. With an updraft design, it requires two filters for optimal operation (not included in the price), providing reliable containment of hazardous particles. Simply plug into a standard 110V or 220V outlet for seamless operation. Certified by UL, CSA, and CE, this enclosure offers unmatched safety and ease of use.

Key Features:

  • Advanced Safety Control: AirSafe™ automatic safety controller for maximum operator protection.

  • Updraft Design: Ensures efficient containment of hazardous particles.

  • Plug-and-Play: No complex installation required.

  • Slip Hatch: Easy access to the enclosed workspace.

  • Certifications: UL, CSA & CE approved.

Benefits:

  • Enhanced Safety: Protects operators from exposure to harmful particles.

  • Easy Operation: Plug-and-play design for quick setup.

  • Efficient Containment: Updraft design and dual filters (not included) ensure optimal performance.

Experience peace of mind with the AirClean Operator Protection Microscope Enclosure, designed to provide a safe and efficient workspace.

AirSafe® Automatic Safety Controller

Product Image
How it Works

A. Room air flows away from the operator and enters the enclosure in a horizontal pattern.

B. Air mixes with gases and particulate.

C. Contaminated air is directed through the filtration bed.

D. Clean air is recirculated into the room.

Airflow Diagram
Features
AirSafe automatic safety controller
No ductwork required
No installation required - plugs directly into a standard 110V or 220V electrical outlet
Encloses equipment while retaining full operator access
Lab event timer
HEPA filtration for capture of particulate to 0.3 microns in size
Gas phase bonded carbon filtration
Benefits
Filter safety lockout to ensure correct filter replacement
Electronic gas detection for real-time gas phase filter monitoring
Tested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1
Brushless, sparkless blower is post-filter
Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas
Low airflow alarm warns the user both visually and audibly
Real time monitoring of installed filtration bed
Options
Fluorescent lighting optional on all 32" width workstations; standard on 48" workstations
ULPA filter
    Product # External Dimensions (Inches)
    (Width x Depth x Height)
    External Dimensions (mm)
    (Width x Depth x Height)
    Internal Dimensions (Inches)
    (Width x Depth x Height)
    Internal Dimensions (mm)
    (Width x Depth x Height)
    AC632TMIC 32 x 24 x 40 813 x 610 x 1016 31 x 23 x 29 787 x 584 x 737
    AC648TMIC 48 x 24 x 42 1219 x 610 x 1067 47 x 23 x 27 1194 x 584 x 686
    Model Details
    TMIC Updraft microscope enclosure with AirSafe automatic safety controller and slip hatch. Requires two filters for operation (sold separately). 110V and 220V, UL, CSA & CE approved.
Manual & Brochures

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY