Skip to content
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Default Title Controlled Room Temperature Cabinets Accucold
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Controlled Room Temperature Cabinets Accucold
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Controlled Room Temperature Cabinets Accucold
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Controlled Room Temperature Cabinets Accucold
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Controlled Room Temperature Cabinets Accucold
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Controlled Room Temperature Cabinets Accucold
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Default Title Controlled Room Temperature Cabinets Accucold
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Controlled Room Temperature Cabinets Accucold
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Controlled Room Temperature Cabinets Accucold
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Controlled Room Temperature Cabinets Accucold
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Controlled Room Temperature Cabinets Accucold
Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet Controlled Room Temperature Cabinets Accucold

Accucold ARS6PV-CRT 6 Cu. Ft. ADA-Height Freestanding Solid-Door Controlled Room Temperature Cabinet

Model / SKU ARS6PV-CRT

$2,311.19 USDStandard delivery calculated at checkout for the contiguous US and DC

$2,311.19

    Dedicated ambient medication storage, matched to the drug label.

    • 6 cu. ft. solid-door cabinet with four adjustable wire shelves
    • Controlled room temperature: 68-77°F (20-25°C), preset to 72°F
    • Buffered product sensing and alarms included; calibrated recording optional
  • Standard dock or liftgate delivery to the contiguous US and DC is calculated at checkout.
  • Alaska, Hawaii and US territories require a quote.
  • Base equipment only. Factory options, racks and monitoring configurations require a quote.
  • Inside placement, stairs and white-glove services are reviewed and quoted separately for your approval.
Need inside delivery or white-glove service?

Please choose one. No surcharge is added here; additional services require a separate quote and your approval.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Controlled room temperature / ARS6PV-CRT

Use a lower-height freestanding cabinet for ambient stock.

The Accucold ARS6PV-CRT gives pharmacy and patient-care teams a 6 cu. ft. ADA-height freestanding cabinet for ambient medication and pharmaceutical storage compatible with drug label requirements. It operates at 68-77°F (20-25°C) and arrives preset to 72°F. Use a labeled shelf map to locate packages quickly behind the solid door.

This is CRT storage, not 2-8°C vaccine refrigeration. Check every product's label and your facility procedures before assigning inventory. A room-temperature cabinet does not make every medication or vaccine compatible.

ARS6PV-CRT authentic solid-door cabinet view
Exact-model manufacturer cabinet photograph. No stored products are included.
6 cu. ft.Published cabinet capacity
68-77°F20-25°C adjustable CRT range
72°F presetFour adjustable wire shelves

Application first

Separate ambient stock from cold-chain inventory.

Start with the required storage condition, then plan the shelf map. Reserve this cabinet for materials that permit the selected controlled room temperature. Separate incoming stock, active inventory and short-dated packages using a layout staff can repeat. Gross capacity is 6 cu. ft.; the CRT manual lists 4.40 cu. ft. net usable. Measure actual package footprints and leave room for airflow.

Plan the shelf positions

Four plastic-coated wire shelves adjust in 1/2-inch increments. The front lip can face upward for small items or reverse to a flat surface for larger packages. Leave clear airflow routes and keep stock away from the internal fans.

Manage access

A factory keyed lock and two keys are standard. The handle has a silver-ion antimicrobial coating. These features support access planning; they do not replace cleaning procedures, stock controls or staff accountability.

Use the door deliberately

Use a labeled shelf map to locate packages quickly behind the solid door. The standard right-hand door is self-closing. Reversal changes that behavior, so review the planned handing and factory monitoring before ordering.

ARS6PV-CRT manufacturer glycol-buffered probe detail
Included product sensing is distinct from optional calibrated recording.

Sensing and circulation

Read the product response, not just a rush of room air.

The standard product-temperature probe sits in a glycol-filled bottle to better simulate stored-product temperature. A separate air sensor supports temperature control. Forced-air cooling circulates air through the cabinet, while automatic adjustable-cycle defrost is designed to limit temperature spikes and ice buildup.

The exact-model page describes stable operation with room temperatures from 68 to 86°F; the CRT manual recommends 72 to 78°F for optimal performance. The reviewed sources do not confirm active heating. Do not treat this as a warming cabinet or assume it will raise cold contents to the chosen setpoint. Have Accucold review any site that needs heating or falls outside the published room conditions.

The published ±1.5°C variation is based on the maximum deviation of an NTC sensor in a 1 oz. vial near the chamber center during a 24-hour test. It is not a guarantee for every shelf position, load or operating condition.

Control and response

Build a response routine around the reading.

The external microprocessor controller allows routine checks without opening the door. Current and resettable min/max temperatures can be viewed in Celsius or Fahrenheit to the nearest tenth of a degree. The manufacturer describes min/max updates in 15-minute increments. Standard C/F capability does not require a paid conversion.

Temperature, door-open, sensor-failure and power-failure alarms help staff identify conditions needing investigation. The battery-powered power-failure alarm is not backup temperature control. Rear dry alarm contacts can connect to a separate alarm system, but do not send messages on their own. Define who responds after hours before loading stock.

ARS6PV-CRT OEM CRT controller and keyed lock
Exact-model OEM controls. Displayed reading is illustrative, not a different operating range.

Included versus optional

Specify ambient-range recording separately.

The buffered product probe, air sensor, local alarms, remote contacts and probe port are standard. A NIST-calibrated data logger or activated cloud service is not included. DL2B is the factory USB logger request; the related logger's published -45 to +120°C measurement range includes 20-25°C CRT storage.

DLPWCRTH is the manufacturer-listed factory CRT temperature/humidity monitoring request. Confirm the complete installed configuration, calibration scope, availability, activation, cellular coverage and recurring service terms before ordering. A separate aftermarket kit is not included or equivalent to factory-installed equipment.

Included with ARS6PV-CRT

Manufacturer ARS6PV-CRT glycol-buffered probe detail

Buffered product probe

Helps approximate stored-product temperature.

Air-temperature sensor

Supports cabinet temperature control.

Manufacturer ARS6PV-CRT external controller and keyed lock

Cabinet control & display

Current and resettable min/max readings.

Local alarms

A response plan is still needed.

Rear dry contacts

Separate alarm system required.

Optional recording and connected monitoring

Calibrated USB logging

DL2B factory option for calibrated USB records at CRT temperatures.

Connected monitoring

DLPWCRTH factory-listed CRT option. Confirm exact code, activation, coverage and service terms.

Functional illustration, not a wiring diagram. Optional systems are not included in the base CRT cabinet.

A min/max display is not a downloadable temperature log. Dry contacts are not an activated notification service, and the power-failure alarm does not provide backup temperature control.

Choose one monitoring request at a time. A new optional choice replaces the prior request. Return to Standard CRT controls to remove the optional selection; factory requests remain subject to a reviewed quote. No loose-kit price is presented as installed equipment. Factory interior options change the shelf layout; confirm usable space and any option combinations in the quote.

Will it fit?

Allow for ventilation, the handle and retrieval space.

The cabinet is 32.5 inches high × 23.38 inches wide × 24.38 inches deep. Handle depth is 26.13 inches. With the door at 90°, depth is 46.5 inches and published open-door width is 23.88 inches. These are cabinet and operating dimensions, not the shipping carton.

ARS6PV-CRT cabinet dimensions with labelled navy height, green width and orange depth arrows: 32.5 inches high, 23.38 inches wide, 24.38 inches cabinet depth.
Height: 32.5 in.Width: 23.38 in.Cabinet depth: 24.38 in.
Tap the diagram to enlarge. ADA-height does not mean built-in. Freestanding indoor use only; at least 5 inches at the back, top and each side; front unobstructed. Depth with handle: 26.13 inches. Depth with door open 90°: 46.5 inches. Confirm final setup, packed dimensions and installation clearances separately.

ADA-height does not mean built-in. Freestanding indoor use only; at least 5 inches at the back, top and each side; front unobstructed. Cabinet dimensions are not the required installation opening. Keep the rear alarm terminals and right-side probe access reachable.

Provide suitable grounded 115 V AC, 60 Hz power for the hospital-grade cord with green-dot plug; published current is 0.75 A. Allow at least two hours upright after unpacking, then follow the CRT manual for stabilization before use. Verify the selected temperature and monitoring arrangement before loading inventory.

Receiving and delivery

Measure the packed route separately.

Manufacturer unit weight is 109 lb. The supplied manufacturer export lists a packed weight of 154.5 lb and packing dimensions of 42.5 H × 31 W × 31 D inches. These are export packing figures, not a guaranteed skid envelope. Confirm final shipment dimensions before measuring doorways, turns, elevators and unloading space.

The current base-model manufacturer page estimates 2 to 3 days to ship. This is supplier processing guidance, not a delivery-date guarantee. Optional factory work and monitoring availability require a fresh lead-time check.

Accucold identifies an embedded lithium-ion battery in this model. For applicable California sales in 2026, the Covered Battery-Embedded Waste Recycling Fee is 1.5% of the retail selling price, capped at $15 per covered product.

FSI lists LTL freight service with supplier overboxing and a custom skid for this model. Checkout retains the original dock-delivery and liftgate options for eligible orders. Multiple-unit or mixed-equipment orders may use freight services. Alaska, Hawaii, US territories and international destinations require a quote.

ARS6PV-CRT manufacturer angled cabinet view
Cabinet photography is not a scale drawing. Confirm final packaging and the receiving route.

Buyer questions

Details that help you decide

Is this a vaccine cold-storage refrigerator?

No. ARS6PV-CRT is a controlled room temperature cabinet with a 68-77°F (20-25°C) range, preset to 72°F. It is not a 2-8°C refrigerator. Use it only for medication or pharmaceutical products whose labeled storage requirements match the intended CRT conditions. Do not infer blanket vaccine compatibility or NSF/ANSI 456 certification.

What shelves and door does it include?

The 6 cu. ft. cabinet has four adjustable plastic-coated wire shelves and a solid white door. Use a labeled shelf map to locate packages quickly behind the solid door. Plan with actual package sizes, not a guaranteed carton or dose count.

Does it actively heat as well as cool?

The reviewed exact-model sources confirm forced-air cooling with internal circulation and stable operation in rooms from 68 to 86°F. They do not establish an active heating function. Do not rely on the cabinet to warm contents or compensate for a cold room; ask Accucold to confirm any installation needing heating.

Can it be recessed into casework?

No. Freestanding indoor use only; at least 5 inches at the back, top and each side; front unobstructed. Allow door-opening and service space too.

Can staff view Fahrenheit without a paid upgrade?

Yes. Celsius/Fahrenheit display capability is standard. The CRT manual explains protected controller settings. The cabinet is preset to 72°F; a standard display and resettable min/max reading are not a downloadable temperature log.

Is calibrated recording included?

No. Standard buffered product sensing, air sensing and alarms control the cabinet. DL2B factory USB logging is optional; its related logger has a -45 to +120°C measurement range covering CRT storage. DLPWCRTH is the CRT-specific factory-listed monitoring request. Confirm calibration, factory code, availability and service terms. Separate aftermarket kits are not installed equipment.

Do the standard contacts send cellular alerts?

No. Rear volt-free dry contacts require a separate alarm system. A probe port supports additional monitoring equipment. Connected alerts need separately specified equipment and activated service; the power-failure alarm does not maintain cabinet temperature.

Can the door swing be changed?

The standard right-hand self-closing base door is user-reversible following the CRT manual, but reversal removes self-closing. Doors with the DL2B logger suffix are not user-reversible. Request LHD and confirm monitoring combinations before ordering.

How do receiving weight and warranty differ from cabinet specifications?

Unit weight is 109 lb. Packed shipping weight is 154.5 lb, with export packing dimensions of 42.5 H × 31 W × 31 D inches. Accucold/FSI handles authorized manufacturer service directly: two-year limited parts/labor coverage within the contiguous 48 US states under written terms and five-year compressor coverage, with compressor replacement labor excluded. Blue Tiger handles purchase and order-return requests.

Equipment and configuration

Bring the complete CRT requirement together.

Review the drug-label storage range, monitoring, door swing and receiving needs in one ARS6PV-CRT-specific proposal.

    SpecificationDetails
    Brand / modelAccucold / ARS6PV-CRT
    Equipment typeAda-height freestanding solid-door controlled room temperature cabinet for ambient medication storage
    Capacity6 cu. ft. gross (170 L); 4.40 cu. ft. net usable per CRT manual
    Control range68-77°F (20-25°C)
    Factory preset72°F
    Application boundaryUse only for products whose labeled storage requirements match CRT conditions; not a 2-8°C vaccine refrigerator
    Cabinet H × W × D32.5 × 23.38 × 24.38 in.
    Depth with handle26.13 in.
    Depth with door at 90°46.5 in.
    Width with door open23.88 in.
    Interior H × W × D24.5 × 20 × 17 in.
    Compressor step H × W × D6.5 × 20 × 5 in.
    DoorSolid white door
    Door swingStandard right-hand self-closing; base user-reversible with loss of self-closing. DL2B doors not user-reversible.
    Shelves4 adjustable plastic-coated wire shelves; 1/2-inch positioning increments
    Cooling / defrostForced-air cooling with internal circulation; automatic adjustable-cycle defrost. Use within the specified ambient room conditions; do not use as a room heater or assume active warming for colder rooms.
    Room conditionsManufacturer-specified ambient room range: 68 to 86°F. Confirm suitability for the intended setpoint and facility conditions; not a cold-room heating solution.
    InstallationFreestanding indoor use only; at least 5 inches at the back, top and each side; front unobstructed.
    ControllerExternal microprocessor controller, current and resettable min/max temperature display, Celsius/Fahrenheit capability standard
    SensingGlycol-buffered product probe plus separate air sensor
    AlarmsTemperature, door-open, sensor-failure and battery-powered power-failure alarms; power-failure alarm is not backup temperature control
    Monitoring connectionsRear volt-free alarm contacts and factory probe access support separate monitoring equipment. Confirm port dimensions and connection hardware before integration; external systems and connected services are separate.
    Security / lightingKeyed lock with two keys; antimicrobial silver-ion-coated handle; LED lighting with internal switch
    Electrical115 V AC/60 Hz; 0.75 A; hospital-grade cord with green-dot plug
    RefrigerantR600a; 1.66 oz.
    Unit weight109 lb; not packed shipping weight
    Packed shipping weight154.5 lb
    Packed shipping H × W × D42.5 × 31 × 31 in.; supplied manufacturer export, confirm final packaging
    Electrical safety listingsETL (US), ETL-C (Canada); no NSF/ANSI 456 certification claim
    Warranty2-year limited parts and labor within contiguous 48 US states under written terms; 5-year compressor replacement excludes labor
    UPC761101090559

    Blue Tiger Scientific is a reseller, not the manufacturer. We manage your purchase and order-return requests. Accucold, a division of Felix Storch, Inc. (FSI), handles manufacturer warranty coverage, service and repairs directly.

    Ordering and delivery

    Availability, dispatch timing and freight depend on the selected equipment, configuration and destination. Delivery dates shown on this page are estimates, not guarantees. Supplier processing, lead time and carrier transit can affect arrival. Contact Blue Tiger before ordering if you have a firm deadline or specific receiving requirements.

    For the base equipment, standard dock or liftgate delivery charges to the 48 contiguous United States and Washington, DC are calculated at checkout. Select dock delivery only if a suitable receiving dock and unloading capability are available. Alaska, Hawaii, US territories and international destinations require a quote. Measure the complete access route and prepare the installation site using the manufacturer’s instructions.

    Standard delivery does not include inside placement, stairs or white-glove services. If additional services are needed, Blue Tiger Scientific will review access, elevators, delivery level and placement requirements and provide a separate quote for your approval before any additional service charge is billed.

    Accucold identifies an embedded lithium-ion battery in this model. For applicable California sales in 2026, the Covered Battery-Embedded Waste Recycling Fee is 1.5% of the retail selling price, capped at $15 per covered product.

    Inspect your delivery

    Inspect the shipment when it arrives. Keep the original cartons, packing materials and delivery paperwork. Report damage, shortages or an incorrect item to Blue Tiger immediately at info@bluetigerscientific.com, with photographs of the item, packaging, shipping label and delivery receipt.

    For freight arranged by FSI or delivered on FSI trucks, FSI instructs recipients to refuse visibly damaged units and have the driver record and acknowledge the damage on the delivery paperwork. On a multi-unit shipment, refuse the damaged units rather than the undamaged remainder. Concealed damage must be reported within five days after delivery acceptance; contact Blue Tiger immediately so the manufacturer’s reporting deadline can be met.

    For customer-nominated, collect or third-party-carrier shipments, claims must be pursued with that carrier. Do not assume FSI will accept a freight-damage return. Contact Blue Tiger for the order information and instructions before arranging any return shipment.

    Order returns must start with Blue Tiger

    All order-return requests must be initiated through Blue Tiger Scientific at info@bluetigerscientific.com. Accucold/FSI does not provide an automatic buyer’s-remorse return right. Eligibility and written authorization must be confirmed before anything is shipped.

    • Contact Blue Tiger within 14 days of delivery to request review, subject to the product-specific manufacturer restrictions. FSI does not accept an eligible factory-sealed return after 30 days from its original shipment date, so request review promptly enough for an authorized return to meet that deadline.
    • Include your Blue Tiger order number, exact manufacturer part number, serial number if applicable, quantity, contact details and reason for the request. Provide the photographs required for the manufacturer’s review.
    • Wait for written return authorization and the designated return address. Do not send an order return to Blue Tiger’s business address or directly to FSI without these instructions.
    • For an eligible non-defective stock return, FSI requires the original unopened carton and an undamaged appliance in new condition. Opened packages are not accepted under that return route.
    • FSI applies a 25% restocking charge per eligible returned item and may charge a higher percentage on larger orders. Your authorization will state the applicable charges. Original outbound freight, including embedded freight on a shipment, reduces the return credit.
    • The customer is responsible for approved non-defective return freight and insurance. Use the authorized carrier and instructions supplied for this heavy equipment. Damage, incorrect-item and defect reports are reviewed separately from an unwanted-product request.

    Customized and factory-upgraded equipment

    FSI excludes made-to-order models with customizations from ordinary returns. Its listed exclusions include factory-installed thermometers, alarms, data loggers and digital-thermostat upgrades, as well as specified lock, door and cabinet customizations. Do not assume a factory-upgraded configuration is returnable. Confirm the exact model’s eligibility before ordering.

    Manufacturer warranty and service go directly to Accucold

    ARS6PV-CRT has a two-year limited parts and labor warranty within the 48 contiguous United States under the written terms and designated-service requirement, plus five-year compressor coverage. Compressor replacement excludes labor. Confirm other destinations with FSI; coverage is not a guarantee of stored-product value. Optional monitors and service subscriptions have separate terms.

    Contact Accucold/FSI directly for warranty coverage questions, claims, service assignment and repair authorization: service@accucold.com or 718-893-3900. Technical questions can be directed to techsupport@accucold.com. Have your model, serial number, proof of purchase, delivery location and a description of the problem ready.

    Blue Tiger Scientific does not administer manufacturer warranty claims, authorize warranty repairs or provide warranty service. Do not commission an independent repair or send equipment for service until FSI provides authorization and instructions. Service not assigned or authorized by FSI may not be covered.

    Manufacturer coverage depends on proper installation, operation and maintenance. The written warranty includes exclusions for matters such as misuse, improper installation, unauthorized modifications and consequential losses, including product spoilage. Equipment warranty coverage is not a guarantee of stored-material value or reimbursement.

    International destinations and service areas

    International customers should request a quote to confirm the equipment configuration, destination eligibility and shipping arrangements. Confirm responsibility for any import duties, taxes and brokerage in the quote. International returns are not permitted under Blue Tiger Scientific’s published return policy.

    Warranty coverage and service arrangements vary by model and destination. Contact Accucold/FSI directly before purchase to confirm service for your exact delivery location. Do not assume worldwide on-site service is included.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.