Skip to content
ARG12PV complete front view with glass door closed
ARG12PV angled view with glass door closed
ARG12PV manufacturer loaded storage illustration; placeholder contents are not included
ARG12PV manufacturer-series external controller and keyed lock detail
ARG12PV manufacturer glycol-buffered probe detail; not a calibrated logger
ARG12PV manufacturer rear dry alarm contacts with illustrative connected leads; external alarm equipment separate
ARG12PV complete front view with glass door closed
ARG12PV angled view with glass door closed
ARG12PV manufacturer loaded storage illustration; placeholder contents are not included
ARG12PV manufacturer-series external controller and keyed lock detail
ARG12PV manufacturer glycol-buffered probe detail; not a calibrated logger
ARG12PV manufacturer rear dry alarm contacts with illustrative connected leads; external alarm equipment separate

Accucold ARG12PV 12 Cu. Ft. Glass-Door Vaccine Refrigerator

Model / SKU ARG12PV

$3,580.00 USDStandard delivery calculated at checkout for the contiguous US and DC

$3,580.00

    Visible stock organization for a dedicated vaccine workflow.

    • 12 cu. ft. glass-door cabinet with seven adjustable wire shelves
    • 61.75-inch cabinet height; freestanding with ventilation clearances
    • Glycol-buffered sensing and alarms standard; calibrated logging optional
  • Standard dock or liftgate delivery to the contiguous US and DC is calculated at checkout.
  • Alaska, Hawaii and US territories require a quote.
  • Base equipment only. Factory options, racks and monitoring configurations require a quote.
  • Inside placement, stairs and white-glove services are reviewed and quoted separately for your approval.
Need inside delivery or white-glove service?

Please choose one. No surcharge is added here; additional services require a separate quote and your approval.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Pharma-Vac / ARG12PV

Give vaccine and pharmacy stock a visible, dedicated home.

The Accucold ARG12PV brings 12 cu. ft. of purpose-built refrigeration to clinics, pharmacies and facilities managing temperature-sensitive inventory. Seven adjustable wire shelves support a consistent layout for receiving, stock rotation and retrieval. The glass door helps staff locate packages before opening, while the external controller keeps routine temperature checks outside the storage space.

Review placement requirements →
ARG12PV manufacturer loaded storage illustration; placeholder contents not included
Manufacturer storage illustration. Placeholder contents are not included.
12 cu. ft.Published refrigerated capacity
+2 to +8°CAdjustable operating range
61.75 inchesActual cabinet height

Dedicated inventory workflow

Make the next retrieval easier to plan.

Use the upright layout to separate active stock from incoming inventory and establish a repeatable shelf map. Double-pane tempered glass makes that layout visible without opening the door. Published volume is a starting point for planning, not a promise of a particular carton or vaccine-dose count.

Organize seven shelves

Assign the seven adjustable shelves by package type or stock rotation needs. Preserve airflow around stored materials rather than filling every gap.

Manage access

The factory-installed keyed lock includes two keys. Define who holds them and keep food and personal items outside this dedicated storage cabinet.

Settle the door swing

The base door ships right-hinged and is user-reversible. Self-closing is specified for the right-hand arrangement only. Review factory-installed options before planning a reversal.

ARG12PV manufacturer glycol-buffered sensing probe; not a calibrated data logger
The standard glycol-buffered probe is separate from optional calibrated recording equipment.

Storage and circulation

Fit the shelf layout to your packages.

Plastic-coated wire shelves reposition at 1/2-inch increments, with a front lip that can face upward for smaller items or reverse to a flat position. Review the usable shelf layout with actual package sizes before deciding how much inventory to assign to the cabinet.

Forced-air cooling uses two internal fans. Automatic defrost has an adjustable cycle, and the LED interior lighting has an internal on/off switch. A white powder-coated metal interior supports an organized working space. The buffered probe helps simulate stored-product temperature rather than simply reporting every change in cabinet air.

Controls and response

Pair the temperature reading with a response routine.

A glycol-buffered product probe and a separate air-temperature sensor are standard. The external microprocessor controller displays current and resettable min/max temperature in Celsius or Fahrenheit to the nearest tenth of a degree. This glass-door model is factory preset to 4°C within its adjustable +2 to +8°C range.

Audible and visual temperature alarms are supplemented by door-open, sensor-failure and power-failure alarms. The battery-powered power-failure alarm does not provide backup cooling. Rear volt-free dry contacts can connect to a separate alarm system; they are not an activated text-message service. Assign responsibility for checks and after-hours response before loading sensitive stock.

ARG12PV actual manufacturer-series controller and keyed lock detail
Standard Celsius/Fahrenheit-capable cabinet controls. Independent logging and connected services are optional.

Included versus optional

Specify the recordkeeping system separately.

Standard controls already support Celsius/Fahrenheit selection through the manual's protected controller parameters. DTFAR is an optional factory setup request, not a purchase of Fahrenheit capability. Set the door swing at the same time as monitoring: factory DL2B configurations require factory reversal. Allow the cabinet to stabilize and verify setpoint, alarms and recordkeeping before loading inventory.

Included with ARG12PV

Glycol-buffered product probe, separate air sensor, local alarms, rear dry contacts and a right-side 1/2-inch probe port. Dry contacts connect to a separate alarm system; they are not an activated notification service.

Choose recording separately

DL2B factory USB logging or the separate DL2BKIT accessory provides calibrated recording. DLPWR is the factory connected-monitoring option; confirm equipment, activation and service terms.

A min/max display is not a downloadable temperature log. Assign responsibility for reviewing readings and responding to alarms. The power-failure alarm does not provide backup refrigeration.

Will it fit?

Plan an upright position with room to ventilate.

The cabinet measures 61.75 inches high, 23.38 inches wide and 24.38 inches deep. Depth is 26.13 inches with the handle and 46.5 inches with the door at 90°. Published width with the door open is 23.88 inches. Include the opening arc and the person retrieving stock when planning the work area.

ARG12PV cabinet dimensions with labelled navy height, green width and orange depth arrows: 61.75 inches high, 23.38 inches wide, 24.38 inches cabinet depth.
Height: 61.75 in.Width: 23.38 in.Cabinet depth: 24.38 in.
Tap the diagram to enlarge. Depth with handle: 26.13 inches. Depth with door open 90°: 46.5 inches. Confirm final setup, packed dimensions and installation clearances separately.

ARG12PV is for freestanding indoor use, not a built-in or recessed installation. The applicable manual requires at least 5 inches at the back, top and each side, with the front unobstructed. Cabinet dimensions alone are not an installation opening size.

Keep the right-side probe port and rear alarm terminals accessible for the planned monitoring arrangement. Check adjacent benches, traffic routes and the final shelf layout together so routine stock rotation does not depend on moving other equipment.

Provide suitable 115 V AC, 60 Hz power for the included hospital-grade cord with green-dot plug. The published current is 1.4 A. Review the Specifications tab and manufacturer documents before placement.

Door access and usable space

Illustrative ARG12PV right-hand door swing, not to scale; overall open-door depth is specified in the adjacent readable text.
Illustrative door swing, not to scale.

46.5 inches overall with the door at 90°. This includes the cabinet, not additional space beyond it. Closed depth is 24.38 inches, or 26.13 inches with the handle. Account for the required rear ventilation space in your room plan.

Interior dimensions are 53 H × 20 W × 17 D inches. Allow for the 6.5 H × 20 W × 5 D inch compressor step; the chamber is not an unobstructed rectangular loading volume.

Freestanding indoor use only. Keep at least 5 inches clear at the rear, top and each side, with the front unobstructed. These are not built-in cutout dimensions.

Before loading inventory

  1. Choose a level location with a floor capable of supporting the fully loaded unit. Preserve access to the rear alarm contacts and right-side probe port.
  2. Plan an exclusive, properly grounded 115 V AC/60 Hz outlet. Follow the manual's electrical instructions; do not remove the grounding prong or use an adapter or extension cord.
  3. After unpacking and setting upright, allow the unit to stand for at least 2 hours before connection, as instructed in the manual.
  4. Before use, allow the unit to run and stabilize for at least 24 hours. Verify the required storage conditions and your facility's monitoring procedure before loading sensitive inventory.

Follow the ARG12PV use and care manual and verify your facility's storage and monitoring requirements before use.

Delivery and receiving

Check the packed route, not just the cabinet footprint.

The manufacturer's unit weight is 190 lb. The packed shipment is listed at 236 lb with dimensions of 71.5 H × 31 W × 31 D inches. Confirm final packaging, doorway heights, turns, unloading capability and any elevator before scheduling receipt.

For the base refrigerator, standard dock or liftgate delivery within the contiguous United States and Washington, DC uses the checkout calculation. Alaska, Hawaii, US territories and international destinations require a destination-specific quote. Inside delivery, stairs and white-glove placement are separate quoted services, not included in standard delivery.

Delivery planning checklist for access, packed dimensions and final placement
Plan the complete receiving route and final setup.

Buyer questions

Details that help you decide

What storage layout does ARG12PV include?

It is a 12 cu. ft. glass-door all-refrigerator with seven adjustable plastic-coated wire shelves. It has no freezer compartment. Check package sizes and airflow needs rather than treating capacity as a guaranteed dose count.

Can it be built into a cabinet opening?

No. This is a freestanding indoor model. The manual requires at least 5 inches at the back, top and each side, with the front unobstructed. Also allow room for door swing and service access.

What temperature is it set to, and can the display use Fahrenheit?

The glass-door model is factory preset to 4°C, with an adjustable +2 to +8°C range. Celsius/Fahrenheit capability is standard. Follow the manual for protected display-unit settings; DTFAR is only an optional factory setup request.

Does purpose-built mean automatic vaccine-program acceptance?

No. The equipment is designed to support CDC/VFC/VFA storage guidelines. Confirm applicable program requirements, independent monitoring and facility procedures before selection; the cabinet alone does not establish acceptance.

Is a calibrated data logger included?

No. The standard glycol-buffered product probe and separate air sensor serve cabinet sensing and control. Select DL2B factory USB logging or the separate DL2BKIT accessory when calibrated recording is needed. DLPWR connected refrigerator monitoring is another optional factory configuration, with service terms to confirm.

Do the standard remote contacts send cellular alerts?

No. They are rear volt-free dry contacts for a separate alarm system. The 1/2-inch probe port also accepts additional monitoring equipment. Neither provides an included cloud subscription or activated cellular notifications.

Can the door be reversed after delivery?

The base right-hand door is user-reversible following the manual. Factory DL2B configurations require factory reversal, so settle the swing before ordering options. Self-closing is specified for the right-hand arrangement only, not promised after reversal.

Is 190 lb the shipping weight?

No. It is the manufacturer's unit weight. Packed shipping weight is 236 lb, with packed dimensions of 71.5 H × 31 W × 31 D inches. Confirm the final shipment and the complete receiving route before delivery.

Who handles warranty service?

Accucold/FSI handles manufacturer warranty questions, authorized service and repairs directly. Published coverage is two years parts and labor and five years compressor coverage, subject to written terms and geographic service limits. Blue Tiger manages order and return requests; do not assume worldwide on-site warranty service.

Equipment and configuration

Bring the complete requirement together.

Review monitoring, door swing, site access and receiving needs in one ARG12PV-specific proposal.

    SpecificationDetails
    Brand / modelAccucold / ARG12PV
    Equipment typeGlass-door all-refrigerator; no freezer compartment
    Published capacity12 cu. ft. (340 L)
    Adjustable control range+2 to +8°C
    Factory preset+4°C, per glass-door model manual
    Cabinet height × width × depth61.75 × 23.38 × 24.38 in.
    Depth with handle26.13 in.
    Depth with door at 90°46.5 in.
    Width with door open23.88 in.
    Interior height × width × depth53 H × 20 W × 17 D in.; compressor step 6.5 H × 20 W × 5 D in.
    ConstructionWhite cabinet and white powder-coated metal interior
    DoorDouble-pane tempered glass; standard right-hand, user-reversible base door; self-closing specified for right-hand arrangement only
    Shelves7 adjustable plastic-coated wire shelves; 1/2-inch positioning increments
    Access / lightingFactory-installed keyed lock with two keys; LED lighting with internal switch
    Included sensingGlycol-buffered product-temperature probe plus separate air sensor
    Included connection pointsRear volt-free remote alarm contacts and right-side 1/2-inch probe port; external monitoring systems separate
    InstallationFreestanding indoor use only; not built-in. At least 5 inches at back, top and each side; front unobstructed.
    Program scopePurpose-built to support CDC/VFC/VFA guidelines; facility procedures and monitoring requirements must be confirmed.
    Cooling / defrostForced air with two internal fans; automatic adjustable-cycle defrost
    Control / displayDigital microprocessor controller; current and resettable min/max display; standard Celsius/Fahrenheit capability
    AlarmsAudible/visual high and low temperature and sensor-failure alarms; adjustable door-open alarm; battery-powered audible power-failure alarm, not backup cooling
    Optional calibrated loggingDL2B USB data logger or DLPWR refrigerator connected monitoring; factory options not included in base equipment
    Electrical115 V AC/60 Hz; 1.4 A; hospital-grade cord with green-dot plug
    RefrigerantR600a; 2.11 oz.
    Manufacturer unit weight190 lb; not packed shipping weight
    Electrical safety listingsETL (US), ETL-C (Canada)
    Manufacturer warranty2-year parts and labor; 5-year compressor. Extended compressor replacement excludes labor; written terms and service limits apply.
    UPC761101062600
    Packed shipping weight236 lb
    Packed shipping dimensions71.5 H × 31 W × 31 D in.; confirm final packaging before delivery

    Blue Tiger Scientific is a reseller, not the manufacturer. We manage your purchase and order-return requests. Accucold, a division of Felix Storch, Inc. (FSI), handles manufacturer warranty coverage, service and repairs directly.

    Ordering and delivery

    Availability, dispatch timing and freight depend on the selected equipment, configuration and destination. Delivery dates shown on this page are estimates, not guarantees. Supplier processing, lead time and carrier transit can affect arrival. Contact Blue Tiger before ordering if you have a firm deadline or specific receiving requirements.

    For the base equipment, standard dock or liftgate delivery charges to the 48 contiguous United States and Washington, DC are calculated at checkout. Select dock delivery only if a suitable receiving dock and unloading capability are available. Alaska, Hawaii, US territories and international destinations require a quote. Measure the complete access route and prepare the installation site using the manufacturer’s instructions.

    Standard delivery does not include inside placement, stairs or white-glove services. If additional services are needed, Blue Tiger Scientific will review access, elevators, delivery level and placement requirements and provide a separate quote for your approval before any additional service charge is billed.

    Inspect your delivery

    Inspect the shipment when it arrives. Keep the original cartons, packing materials and delivery paperwork. Report damage, shortages or an incorrect item to Blue Tiger immediately at info@bluetigerscientific.com, with photographs of the item, packaging, shipping label and delivery receipt.

    For freight arranged by FSI or delivered on FSI trucks, FSI instructs recipients to refuse visibly damaged units and have the driver record and acknowledge the damage on the delivery paperwork. On a multi-unit shipment, refuse the damaged units rather than the undamaged remainder. Concealed damage must be reported within five days after delivery acceptance; contact Blue Tiger immediately so the manufacturer’s reporting deadline can be met.

    For customer-nominated, collect or third-party-carrier shipments, claims must be pursued with that carrier. Do not assume FSI will accept a freight-damage return. Contact Blue Tiger for the order information and instructions before arranging any return shipment.

    Order returns must start with Blue Tiger

    All order-return requests must be initiated through Blue Tiger Scientific at info@bluetigerscientific.com. Accucold/FSI does not provide an automatic buyer’s-remorse return right. Eligibility and written authorization must be confirmed before anything is shipped.

    • Contact Blue Tiger within 14 days of delivery to request review, subject to the product-specific manufacturer restrictions. FSI does not accept an eligible factory-sealed return after 30 days from its original shipment date, so request review promptly enough for an authorized return to meet that deadline.
    • Include your Blue Tiger order number, exact manufacturer part number, serial number if applicable, quantity, contact details and reason for the request. Provide the photographs required for the manufacturer’s review.
    • Wait for written return authorization and the designated return address. Do not send an order return to Blue Tiger’s business address or directly to FSI without these instructions.
    • For an eligible non-defective stock return, FSI requires the original unopened carton and an undamaged appliance in new condition. Opened packages are not accepted under that return route.
    • FSI applies a 25% restocking charge per eligible returned item and may charge a higher percentage on larger orders. Your authorization will state the applicable charges. Original outbound freight, including embedded freight on a shipment, reduces the return credit.
    • The customer is responsible for approved non-defective return freight and insurance. Use the authorized carrier and instructions supplied for this heavy equipment. Damage, incorrect-item and defect reports are reviewed separately from an unwanted-product request.

    Customized and factory-upgraded equipment

    FSI excludes made-to-order models with customizations from ordinary returns. Its listed exclusions include factory-installed thermometers, alarms, data loggers and digital-thermostat upgrades, as well as specified lock, door and cabinet customizations. Do not assume a factory-upgraded configuration is returnable. Confirm the exact model’s eligibility before ordering.

    Manufacturer warranty and service go directly to Accucold

    The ARG12PV manufacturer documentation lists a two-year limited warranty for the appliance and a five-year compressor warranty. Extended compressor replacement coverage does not include replacement labor. Monitoring devices and service subscriptions have their own applicable terms; do not assume they share the cabinet’s coverage.

    Contact Accucold/FSI directly for warranty coverage questions, claims, service assignment and repair authorization: service@accucold.com or 718-893-3900. Technical questions can be directed to techsupport@accucold.com. Have your model, serial number, proof of purchase, delivery location and a description of the problem ready.

    Blue Tiger Scientific does not administer manufacturer warranty claims, authorize warranty repairs or provide warranty service. Do not commission an independent repair or send equipment for service until FSI provides authorization and instructions. Service not assigned or authorized by FSI may not be covered.

    Manufacturer coverage depends on proper installation, operation and maintenance. The written warranty includes exclusions for matters such as misuse, improper installation, unauthorized modifications and consequential losses, including product spoilage. Equipment warranty coverage is not a guarantee of stored-material value or reimbursement.

    International destinations and service areas

    International customers should request a quote to confirm the equipment configuration, destination eligibility and shipping arrangements. Confirm responsibility for any import duties, taxes and brokerage in the quote. International returns are not permitted under Blue Tiger Scientific’s published return policy.

    Warranty coverage and service arrangements depend on the destination and written model warranty. Contact Accucold/FSI directly before purchase to confirm coverage and authorized service for your exact location; do not assume worldwide on-site coverage.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.