Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

5X Luciferase Lysis Buffer Chemicals Molecular Depot
5X Luciferase Lysis Buffer Chemicals Molecular Depot
5X Luciferase Lysis Buffer Chemicals Molecular Depot
5X Luciferase Lysis Buffer Chemicals Molecular Depot

5X Luciferase Lysis Buffer

$595.00

    Catalog Number: B2015400 (15 mL)

    5X Luciferase Lysis Buffer is a five-fold concentrated buffer for preparing cell lysates for firefly luciferase reporter gene assays. Dilute to 1X with ultrapure water, lyse transfected cells, and read luciferase activity in the cleared lysate with your luciferase assay reagent. Used in promoter studies, signaling reporter assays and transfection checks. Store at −20°C. Custom bulk amounts of this product are available upon request.

    Products are for in vitro research use only (RUO).

    Live Inquiry about this product via:

    Email: info@bluetigerscientific.com

    Text/SMS: (833) 928-4437 Mon–Fri, (8 am – 8 pm PST)

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

For purchasing details or COA/TDS availability, please request a quote.

Preparing Quote Cart. Your shopping cart stays unchanged.

5X Luciferase Lysis Buffer – Catalog #B2015400

5X Luciferase Lysis Buffer (Catalog #B2015400) is a five-fold concentrated buffer for preparing cell lysates that will be read in a luciferase reporter assay. Dilute it to 1X, lyse your transfected cells, and measure luciferase activity in the cleared lysate after adding luciferase assay reagent.

Catalog number: B2015400
Lot number: Batch Dependent
Expiration Date: Batch dependent
Amount: 15 mL
Molecular Weight or Concentration: N/A
Supplied as: Solution
Applications: Cell lysis for firefly luciferase reporter gene assays, promoter and enhancer studies, transfection efficiency checks, screening with luciferase reporters
Storage: -20°C
Keywords: 5X Luciferase Lysis Buffer, luciferase cell lysis buffer, reporter lysis buffer, luciferase reporter assay
Grade: Biotechnology grade. All products are highly pure. All solutions are made with Type I ultrapure water (resistivity >18 MΩ-cm) and are filtered through 0.22 um.

Scientific Overview

In a luciferase reporter assay, a promoter or other regulatory sequence drives expression of the firefly luciferase gene in cultured cells. The cells are then lysed and the amount of active luciferase in the lysate is measured as light after adding luciferin and ATP. The lysis step has to release the enzyme without destroying its activity, which is the job of a dedicated luciferase lysis buffer. The firefly luciferase gene was first characterized and expressed in mammalian cells by de Wet and colleagues in 1987, and the lysate-based assay has been a standard readout for gene regulation ever since.

  • Promoter, enhancer and transcription factor studies
  • Signaling pathway reporter assays
  • Transfection and delivery efficiency checks
  • Reporter-based screening

Usage & Handling Guidance

The steps below are the general workflow from published luciferase assay protocols. Optimize volumes and times for your cell type and plate format.

  • Dilute to 1X: mix 1 part 5X buffer with 4 parts ultrapure water. Bring the 1X buffer to room temperature before use.
  • Lyse: remove the medium, rinse cells with PBS, add enough 1X buffer to cover the cells, and incubate or scrape to complete lysis.
  • Clear: spin briefly to pellet debris and transfer the supernatant.
  • Read: assay the lysate promptly, or freeze it at −70°C or below. Avoid repeated freeze-thaw cycles.
  • Storage: keep the 5X concentrate at −20°C.

Frequently Asked Questions (FAQ)

  • Does this include luciferin or assay reagent?
    No. This is the lysis buffer only. You need a luciferase assay reagent with D-luciferin and ATP for the read step.
  • How much 1X buffer does one bottle make?
    The 5X concentrate makes five times its volume of 1X working buffer.
  • Is it compatible with other reporters such as Renilla luciferase or beta-galactosidase?
    The formulation is not published, so compatibility with other reporter enzymes is not confirmed. Contact us before planning a dual-reporter experiment.
This product is for Research Use Only (RUO). It is not intended for diagnostic or therapeutic use in humans or animals.

References

  • Smale ST. Luciferase assay. Cold Spring Harb Protoc. 2010;2010(5):pdb.prot5421.Reference
  • de Wet JR, Wood KV, DeLuca M, Helinski DR, Subramani S. Firefly luciferase gene: structure and expression in mammalian cells. Mol Cell Biol. 1987;7(2):725-737.Reference
  • Wang CJ, Hsu SH, Hung WT, Luo CW. Establishment of a chimeric reporting system for the universal detection and high-throughput screening of G protein-coupled receptors. Biosens Bioelectron. 2009;24(7):2298-2304.Reference
  • Tavva VS, Dinkins RD, Palli SR, Collins GB. Development of a methoxyfenozide-responsive gene switch for applications in plants. Plant J. 2006;45(3):457-469.Reference

    Terms & Conditions

    Blue Tiger Scientific is an independent third-party distributor of select products manufactured by Molecular Depot LLC. By purchasing from bluetigerscientific.com, you (“the Customer”) agree to the following terms, adapted from Molecular Depot’s original conditions:

    Product Use & Eligibility
    Products are for in vitro research use only (RUO). They are not intended for human or animal use, diagnosis, therapy, resale to consumers, or residential delivery. Sales are limited to verified business addresses.

    Payment Terms
    All purchases are prepaid and non-refundable once confirmed. Pricing is in USD and subject to change without notice.

    Purchase Orders
    Confirmed orders are final and may not be canceled or refunded unless authorized in writing.

    Limitation of Liability
    Blue Tiger Scientific and Molecular Depot LLC are not responsible for any damages resulting from product use or misuse.

    Waiver of Claims
    By ordering, you waive all claims arising from use of Molecular Depot products.

    Shipping & Handling
    Shipping is calculated at checkout. A minimum 27% handling fee applies to each order.

    Delivery Estimates All delivery timelines are estimates and not guaranteed. FedEx service levels are subject to operational delays, weather disruptions, and regional restrictions.

    FedEx Pickup Cutoff Orders submitted after the daily FedEx pickup window may not ship until the next available pickup day.

    Shipping Exceptions FedEx may impose restrictions or delays due to package size, weight, destination, or service availability. Blue Tiger Scientific is not liable for delays beyond our control.

    Weekend & Holiday Handling Orders placed on weekends or holidays will be processed on the next business day.

    Returns & Refunds
    Returns must be requested within 30 days through Blue Tiger Scientific. Refunds are only issued for shipping errors or verified defects, and processed within 45 business days if approved. Customers are responsible for return shipping costs unless otherwise stated. Refunds will exclude original shipping fees paid at checkout.

    Warranty Disclaimer
    All products are provided "as-is" with no warranties. Warranty issues are handled by the manufacturer.

    Safety Guidelines
    Always consult the product’s SDS. Products must not be ingested, inhaled, or come into contact with skin or eyes unless specified.

    Legal Use Compliance
    Products must not be used in violation of any law—local, state, federal, or international.

    Accuracy of Orders
    Customers are responsible for verifying all order details before submission.

    Changes or Cancellations
    All changes must be in writing and approved. Cancellations may result in fees for materials, labor, or third-party costs.

    Quality System (MD Levels)
    Molecular Depot’s MD-Quality System includes:

    MD 1000: Non-regulated use, no change notification

    MD 2000: Non-regulated use, limited change notification

    MD 3000: Regulated use, enhanced quality standards

    Delivery & Claims
    Orders may ship in parts. Claims for shortages or defects must be submitted within 2 days of receipt. Delivery dates are estimates only.

    Extended Payment Terms
    Payment is due within 30 days unless agreed otherwise. A 5% weekly penalty applies to late payments. Blue Tiger Scientific reserves discretion on payment application.

    Retention of Title
    Ownership remains with Blue Tiger Scientific or Molecular Depot LLC until payment is complete. Goods must be stored separately and labeled until paid in full.

    Intellectual Property
    No rights to manufacturing processes or IP are transferred. Blue Tiger Scientific is not liable for IP-related claims.

    Force Majeure
    Neither party is liable for delays or failures caused by uncontrollable events (e.g., weather, regulations, supply disruptions).

    Manufacturing Access
    Product purchase does not grant access to proprietary manufacturing documents or methods.

    Resale Prohibition
    Products cannot be resold without written approval from Molecular Depot LLC. Blue Tiger Scientific enforces this restriction.

    Governing Law
    Terms are governed by California and U.S. law. All disputes fall under U.S. jurisdiction.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.