Milwaukee MA9007 pH 7.01 Calibration Solution Milwaukee Instruments
Milwaukee MA9007 pH 7.01 Calibration Solution Milwaukee Instruments
Milwaukee MA9007 pH 7.01 Calibration Solution Milwaukee Instruments
Milwaukee MA9007 pH 7.01 Calibration Solution Milwaukee Instruments

Milwaukee MA9007 pH 7.01 Calibration Solution

$18.37

    The pH reference your lab needs, in the bottle size it uses. Ready-to-use pH 7.01 calibration buffer eliminates powder mixing. Choose 230 mL, 500 mL or 1 L to match your lab’s consumption.

    • Specified buffer accuracy: ±0.01 pH at 25 °C
    • One bottle per order unit, in the selected size
    • Representative photo: choose the pack size from the selector

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

A pH 7.01 reference, in the bottle size you use

Keep a near-neutral reference at the calibration bench. Milwaukee MA9007 provides a ready-to-use pH 7.01 buffer at 25°C for instruments whose calibration procedure calls for that standard. The 230 mL, 500 mL and 1 L choices let you match the amount on hand to your routine.

The specified buffer accuracy is ±0.01 pH. Use it as a reference in the calibration procedure supported by your meter; selecting a buffer does not replace checking the instrument’s required calibration points or the condition of its electrode.

Representative Milwaukee pH 7.01 buffer bottle; size selected separately
Representative Milwaukee MA9007 pH 7.01 buffer bottle. The source photo shows the base family label; select 230 mL, 500 mL or 1 L from the bottle-size options, not from the photograph.

Choose a bottle size

230 mL (MA9007): the smallest bottle in this family, suited to a modest bench supply. 500 mL (MA9007-500): an intermediate volume for a more regular routine. 1 L (MA9007-1000): the largest bottle option for higher consumption. Choose the volume you can use within the instructions and expiry shown on the supplied container; a larger bottle does not mean a stronger buffer.

Each selection is one bottle. Bottle volume is not the number of calibrations: the amount required depends on your electrode, vessel and instrument procedure.

Ordering guide

Manufacturer code Order unit / selected pack
MA9007 230 mL : 1 bottle
MA9007-500 500 mL : 1 bottle
MA9007-1000 1 L : 1 bottle

Build a clean calibration routine

  1. Check that your instrument supports a pH 7.01 calibration point and follow its specified buffer sequence and preparation instructions.
  2. Check the bottle label and expiry. Pour a fresh portion into a clean calibration vessel; keep the stock bottle closed between pours.
  3. Prepare and rinse the electrode as directed in its manual. Immerse it to the required depth, allow the reading to stabilize and complete the instrument’s calibration procedure.
  4. Keep used buffer separate from the stock solution. Follow the instrument manual for rinsing between calibration points, cleaning and storage.

Temperature, electrode condition and handling all matter. Use the temperature information on the buffer label and the calibration directions for your instrument. Check the supplied pack’s expiry before use; no fixed remaining shelf life is promised.

Alternative format and related workflow

Frequently asked questions

What does pH 7.01 at 25°C mean?

The stated reference value is pH 7.01 at 25°C. Buffer pH can vary with temperature; use the label’s temperature information and your instrument’s calibration instructions rather than assuming the 25°C value applies at every temperature.

Does a larger pack change the buffer accuracy?

No. The listed bottle sizes share a specified buffer accuracy of ±0.01 pH. This is the solution specification, not a guarantee of the accuracy of your complete meter-and-electrode system.

Which bottle size should I select?

MA9007 supplies one 230 mL bottle, MA9007-500 one 500 mL bottle and MA9007-1000 one 1 L bottle. Match the volume to your consumption and the expiry on the supplied bottle.

Should I calibrate in the stock bottle?

Pour a fresh portion into a clean vessel and calibrate there, as Milwaukee describes. Keep the stock bottle closed and do not return used buffer to it.

Can I use this instead of electrode storage solution?

No. This product is a calibration buffer. Use the storage and cleaning products specified for your electrode; those are separate from the buffer and are not included.

How often should I calibrate?

Milwaukee’s general buffer guidance recommends calibration at least monthly and whenever readings become suspect. Follow your instrument manual and your own quality procedure if they require more frequent calibration; there is no single schedule for every application.

Is a certificate of analysis included?

The manufacturer lists no included certificate of analysis for the package options shown here. The stated ±0.01 pH buffer accuracy should not be read as a promise of a supplied lot-specific certificate.

How much shelf life remains when I receive it?

No fixed remaining shelf life is promised here. Check the expiry and handling instructions on the supplied bottle or sachet before use. An unopened pack must still be within its marked expiry; sealed packaging does not make expired buffer suitable for calibration.

    Product Specifications

    SpecificationDetails
    BrandMilwaukee Instruments
    Product familyMilwaukee MA9007
    Buffer value at 25°CpH 7.01
    Specified buffer accuracy±0.01 pH
    Formulation / useReady-to-use liquid pH calibration buffer
    Package options230 mL : 1 bottle; 500 mL : 1 bottle; 1 L : 1 bottle
    Manufacturer codesMA9007; MA9007-500; MA9007-1000
    Package protectionBottle sealed against light; airtight, tamper-proof cap
    Certificate of analysis includedNo
    Selection noteSelect the exact code and package in the ordering guide; photograph is representative

    Ordering Information

    Catalog numberPack / order unit
    MA9007230 mL : 1 bottle
    MA9007-500500 mL : 1 bottle
    MA9007-10001 L : 1 bottle

    Milwaukee Instruments Warranty & Returns Policy
    (For Milwaukee Instruments ONLY – Not for Milwaukee Tools)

    How to Initiate a Return or Warranty Claim
    For products purchased through Blue Tiger Scientific, all returns must be initiated directly with us. However, all warranty claims must be handled directly through Milwaukee Instruments.

    Warranty Information
    Milwaukee Instruments products are manufactured to meet the highest quality standards and come with a limited warranty against defects in materials and workmanship. Products may be returned for repair or replacement at Milwaukee's discretion. Warranty is void if the product has been abused, misused, or repaired by unauthorized persons.

    To register your Milwaukee product, click here.

    Warranty Periods

    • Handheld testers, portable meters, and stationary monitors/controllers: 2 years
    • Bench meters: 3 years
    • PH600 pH Pen and similar versions: 1 year
    • Replaceable probes: 6 months

    Warranty begins on the original end-user purchase date or a maximum of 12 months from dealer purchase. Valid only with proper usage and maintenance. Service occurs at Milwaukee Instruments' North Carolina Technical Service Center.

    Note: Meters used in Kangen Water or “Negative ORP Water” applications are excluded from warranty coverage. Any warranty for these uses is null and void.

    Filing a Warranty Claim
    Contact Milwaukee Instruments Customer Service at (252) 443-3630 EST for an RMA number. Mark the RMA clearly on the box and ship prepaid. Improper packing can void the warranty.

    Return Policy (Blue Tiger Scientific)
    All purchases are final, but returns may be accepted under specific conditions:

    • Items must be in new condition with original packaging and contents.
    • Returns must be initiated within 14 days of purchase.
    • Subject to up to 30% restocking fee.
    • Customer pays all return shipping.
    • Initial shipping charges are non-refundable.

    Returns will be refused if packaging is damaged or contents are missing.

    Initiating a Return with Blue Tiger Scientific
    Contact Blue Tiger Scientific for an RMA and shipping instructions. Mark RMA clearly and pack securely to avoid transit damage. Shipping damage claims are the sender’s responsibility.

    Refunds, if eligible, will be processed within 5–10 business days. Credit card refunds may take longer to appear on your statement.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.