Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Default Title Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Default Title Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA
IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V Rotary Evaporator Complete System IKA

IKA RV 10 auto pro V-C Complete Rotary Evaporator Kit, 115 V

$16,460.00

    A defined Auto workflow, with the core vacuum and cooling equipment supplied. US IKA 0010007358 combines RV 10 auto pro, HB digital, VACSTAR digital, coated glassware, RC 2 lite and VSE 1.

    • US 115 V, 50/60 Hz complete package
    • TFT operation and integrated vacuum control
    • Automatic boiling-point detection with correct pump, cooling and method setup
    • Coated vertical glassware; 5–280 rpm exact package specification

    Shipping: Mainland equipment delivery uses a provisional 190 lb aggregate packed-weight allowance, not manufacturer-measured gross or a single-parcel claim. Alaska/Hawaii freight, territories, international destinations and special services require a quote. Automatic arrival dates are estimates until confirmed.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

IKA RV 10 AUTO PRO V-C COMPLETE • 0010007358 • US 115 V

Integrated vacuum control. A matched complete kit. A defined path into Auto distillation.

Choose a rotary-evaporation package that brings the Auto drive, heating bath, vacuum pump, coated vertical glassware and recirculating chiller together under one manufacturer-defined order code. US catalog 0010007358 adds IKA’s TFT operation and integrated vacuum controller rather than a separate VC 10 lite control box.

The included VACSTAR digital is controlled from the RV 10 Auto drive and supports automatic boiling-point detection when the system and method meet the operating conditions. It is an automation choice, not a promise of greater flask capacity, universal solvent handling or an unattended process.

The package includes the HB digital bath, RC 2 lite chiller, RV 10.910 coated vertical glassware, VSE 1 and H.SI.8 tubing. Compare its control approach with the Digital Complete kit before deciding which workflow belongs on your bench.

Manufacturer photograph of the RV 10 auto pro V-C Complete with heating bath, pump, coated glassware and chiller
Manufacturer package photograph. Display values are illustrative. Order scope follows the US 0010007358 checklist; sample, fluids, software and facility services are not established as supplied.
Integrated controlVacuum controller in the Auto system
5–280 rpmExact package speed specification
1,500 cm²Published vertical-condenser cooling surface
US 115 VRegional package 0010007358

A QUICK BUYING DECISION

Is the Auto complete package right for your lab?

Choose Auto when the vacuum-control workflow matters

The matching VACSTAR digital and integrated controller support speed-controlled vacuum operation and automatic boiling-point recognition under the method’s conditions. Choose this route when that capability contributes to your evaporation workflow, not simply because Auto sounds more powerful.

Specify the whole core setup at once

The factory package supplies the evaporator, bath, pump, chiller, coated glassware and listed connections. You can assess a defined hardware scope rather than discover that a bare drive still needs its vacuum and cooling equipment.

Keep manual control available for method development

The Auto drive provides manual and programmed operating routes as described in its instructions. Start with a suitable, reviewed method; unfamiliar evaporation processes must not simply be handed over to automatic operation.

Choose Digital if its control route already meets the job

The linked Digital Complete kit uses an external VC 10 lite rather than Auto’s integrated controller. Both are complete-package choices with pump, bath, chiller and coated glassware. Compare the control functions and exact scope, not an assumed increase in batch size.

Automation does not remove process limits.

Select a different setup or seek manufacturer guidance if the required batch, material, pressure, cooling duty or facility conditions fall outside the delivered system’s limits. This is laboratory rotary evaporation, not pressure-reaction equipment, a guaranteed continuous production plant or approval to process every hazardous mixture.

What comes in US package 0010007358?

The complete Auto package shown as one manufacturer-defined hardware selection
The same package shown again for the checklist, not a second system. A protective enclosure, process sample and consumables are not established as included.

A defined factory package, not an invented bundle

  • RV 10 auto pro rotary evaporator with integrated vacuum control and TFT interface.
  • HB digital heating bath, identified in the exact package description.
  • VACSTAR digital vacuum pump, controlled through the Auto system’s supplied connection arrangement.
  • RV 10.910 vertical coated glassware set.
  • RC 2 lite recirculating chiller.
  • VSE 1 vacuum safety emission condenser.
  • H.SI.8 tubing, as named in the current US order scope.

Plan the appropriate bath fluid, chiller fluid, enclosure/exhaust arrangement and facility electrical supply against the component instructions. The drive manual specifies an all-side-closed extraction or protective enclosure and routing pump exhaust under a fume hood; these facility requirements must be arranged separately. These needs are not removed by the phrase Complete. A labworldsoft software license, protective cabinet and every possible accessory or consumable are not established as part of this order.

The glassware installation instructions identify a 1,000 mL evaporating flask in the covered set family. Do not read the package table’s bath-fill figure as a permitted sample charge, assume an additional large flask is supplied or choose spare joints from another region’s illustration.

The Auto control advantage: drive and pump working together

Genuine Auto TFT control-panel detail from the manufacturer kit photograph
Actual Auto interface crop. Readings are illustrative. The vacuum-control function belongs to the Auto system, not an extra external VC 10 lite supplied with this order.

Speed-controlled vacuum, rather than simply copying a pressure setting

The Auto manual distinguishes a compatible speed-controlled pump from two-position vacuum-valve operation. With the matching VACSTAR digital connected correctly, pump speed adjusts as measured pressure approaches the target. The manufacturer identifies this arrangement as the basis for automatic boiling-point recognition.

The TFT interface provides the operating values, menu guidance and access to supported modes and programs. The exact package also supports soft start, reversible/interval rotation, timed operation and ramp programming, subject to the drive instructions.

Keep the control routes distinct. Do not add a second VC 10 lite controller or assume the manual’s RV 10 control two-position valve diagram is the Auto connection scheme. The Auto manual specifically says the RV 10.4002 vacuum valve is not required and must not be connected for this speed-control arrangement.

The chiller remains its own component with its own operating instructions. A matched package does not mean every component setting or every safety requirement is replaced by one button on the TFT display.

Automatic boiling-point detection needs the right cooling conditions

The condenser circuit is part of the measurement

The drive manual describes Auto operation using the temperature difference between cooling-water inlet and outlet. It specifies measured flow in the 30–100 L/h range and a constant 18–22°C reference cooling-water range. Correct inlet/outlet installation matters; reversed connections can prevent automatic distillation.

A chiller rating is not proof of actual condenser flow

RC 2 lite supplies recirculating cooling, but its free-flow pump rating is not the measured flow through the installed condenser circuit. Choose the coolant and settings under both component manuals and verify the actual setup rather than assume the −10°C chiller capability is the right Auto-mode setting.

Review a process before automating it

The manual requires evaporation processes to be verified before automatic use and says unfamiliar processes must not be run automatically. Solvent mixtures, foaming, bumping, thermal sensitivity and vapor load require method-specific assessment. Auto is not an unattended-operation or guaranteed-endpoint claim.

VACSTAR digital and VSE 1: a defined vacuum path

Included VACSTAR digital pump model shown separately in a manufacturer photograph
Component photograph of the included pump model, not a second pump. Follow the supplied pump and VSE instructions for installation, exhaust and chemical compatibility.

Control the pump and manage the exhaust properly

The VACSTAR digital provides the compatible pumping route for the Auto drive. IKA quotes a 2 mbar final pressure for the pump. That is a component specification, not a guaranteed process pressure for every solvent, gas load, leak rate or operating temperature.

VSE 1 is included as a vacuum safety emission condenser. It supports solvent-vapor management under its specified installation and operating conditions, but it does not replace a suitable laboratory ventilation and exhaust strategy or guarantee zero emissions.

Keep the vacuum path, cooling path and exhaust arrangement distinct, and assess wetted-material compatibility for the actual media. Never treat an ultimate-vacuum figure as permission for overpressure, arbitrary reactive mixtures or unrestricted hazardous-vapor discharge.

Coated vertical glassware is a specification, not a safety shortcut

Match the delivered US parts before selecting accessories

The specified set is RV 10.910 vertical coated glassware, with a published 1,500 cm² condenser cooling surface in the exact package data. The transparent coating can help retain fragments if coated glass breaks; it does not make damaged glass safe or turn the apparatus into explosion-protected equipment.

The manufacturer’s glassware installation notes give separate temperature limits for the coated material, including a −30 to +60°C range for the specified Surlyn-coated parts. Do not assume the bath’s 180°C capability is a temperature rating for every coated component. Identify which delivered pieces are coated and follow their instructions.

Inspect glass and seals, avoid mechanical stress and observe the drive’s lift and flask-load instructions. Use the delivered US component codes when choosing replacements; an NS 29 family illustration is not proof that every joint on this US package uses that standard.

Coated vertical glassware detail from the Auto kit photograph
Manufacturer-photo detail of the same supplied set. No extra condenser or flask is added by this illustration. Verify the delivered components and applicable coated-part limits.

HB digital: choose the fluid and fill for the actual flask

HB digital bath detail from the Auto package photograph
Actual bath in the kit image. Displayed values are illustrative; bath fluid, fill and sample method must follow the supplied instructions.

The bath rating is not a sample-temperature guarantee

IKA describes the included HB digital as a 4 L water/oil heating bath with a room-temperature-to-180°C heating range. Choose the approved bath fluid for the temperature and observe the actual fill marks, flask displacement, residual heat and the delivered bath instructions.

The exact kit table and the bath manual contain different maximum-fill and electrical-power figures. For that reason this page does not turn a single conflicting table value into a guaranteed maximum working fill or a combined electrical-load rating for the whole package.

Do not interpret a nominal bath capacity as the amount of sample to put in the evaporating flask. Verify the permitted flask charge, immersion, lift travel and load together. Facility electrical planning must account for each component’s rating plate; one-outlet operation is not promised.

RC 2 lite: condenser cooling without a mains-water assumption

A supplied chiller, not unlimited cooling capacity

The RC 2 lite is part of the package and uses R290 refrigerant. The manufacturer quotes a 400 W cooling-capacity reference and cooling capability down to −10°C, but available capacity depends on operating temperature and conditions. Do not assume 400 W is available at every setpoint or that the coldest setting is appropriate for Auto detection.

The chiller manual specifies component pump limits and coolant requirements. Keep the actual condenser flow and pressure within the limits of every connected part, including the glassware. Use the approved fluid and observe fill, ventilation, ambient and refrigerant precautions in the manual.

Condenser temperature, vapor generation and capture need to work together. If the required duty exceeds the chiller or condensation setup, reducing pressure or increasing the bath setting is not automatically the answer.

RC 2 lite chiller detail from the Auto package photograph
The included chiller shown as a genuine kit-photo crop. Illustrative display, not a recommended temperature or a guarantee of cooling duty.

A practical Auto evaporation workflow

Corrected Auto workflow: configure, establish cooling and vacuum, warm and rotate, condense and collect
Conceptual roles only, not tubing, valve or safety instructions. Configure and verify the method before using automatic operation.

Configure the method first, then use the control functions

  • Inspect and correctly assemble the delivered glassware, seals and flask; select a suitable charge and safe material handling arrangement.
  • Check the lift, end stop, permitted load, bath fluid/fill and the manufacturer’s daily safety-lift test before operation.
  • Connect the cooling and vacuum routes exactly as specified, including the compatible pump data connection and the correct condenser inlet/outlet. Follow the mode-specific commissioning sequence: evacuate the glassware before heating the sample, and keep the evaporating flask rotating during heating.
  • Set the appropriate temperatures, rotation and mode for a reviewed method. Confirm actual flow and cooling conditions before automatic detection.
  • Observe condensation and collection, then follow the correct stopping, cooling and pressure-equalization sequence before opening or cleaning.

Automatic boiling-point detection and volume-dependent distillation are different control routes. The manual says those two modes are mutually exclusive; volume-based operation needs its own solvent/efficiency setup and a test distillation. It is not an uncalibrated promise to collect an exact volume from any mixture.

Digital or Auto: choose the control workflow

Original Digital Complete versus Auto Complete decision guide
Both referenced products are complete-package selections. This order is US Auto 0010007358; Digital 0010012821 is a separate alternative.

Choose this Auto kit for the integrated approach

TFT operation, integrated vacuum control and supported automatic boiling-point recognition with the matched VACSTAR digital. Choose it when those functions support a reviewed, suitable process and correct cooling setup.

Choose Digital when its external-controller route fits

The Digital pro V-C Complete kit uses the separate VC 10 lite controller. It still supplies a bath, pump, chiller and coated glassware, so Auto should not be sold as merely adding equipment that Digital lacks.

Do not choose Auto as an assumed scale-up

No higher batch capacity, universal processing speed or solvent-recovery percentage is promised here. Check the delivered flask, charge, condenser duty, pressure and safety limits against the actual application.

Care, safety and warranty by component

Coated glassware, heated fluid, vacuum, rotating equipment, solvent vapor and R290 refrigeration each have their own handling requirements. Do not run damaged equipment, bypass protections, treat the system as overpressure-rated or assume it is explosion-protected. Trained staff must assess the medium and facility conditions.

The drive instructions limit flask filling to no more than half its volume and give a separate 3 kg maximum for the evaporating flask plus its contents. The standard-assembly daily safety-lift check uses 3.1 kg total glassware plus solvent, not 3.1 kg of solvent alone. These are separate constraints, not interchangeable sample allowances; the safe charge may be lower for the actual glassware, balance and method. Follow the delivered configuration and test the safety lift daily.

Stop, allow safe handling temperatures, isolate power and follow the required pressure-equalization, cleaning and decontamination instructions. Blue Tiger Scientific handles purchase and return requests; IKA handles manufacturer technical support, warranty assessment, calibration where applicable and repairs.

The current exact-package page states a standard two-year warranty. It describes registration extensions of three additional years for the rotary evaporator and heating bath, and one additional year for the included pump and chiller, subject to IKA’s registration requirements, terms and exclusions. This is not an unconditional five-year warranty on every item in the package.

Related equipment and alternative workflows

Alternative model: RV 10 digital pro V-C Complete, US 115 V for the external VC 10 lite control route. Compare the control features and current package scope, not just the shared RV 10 name.

Related workflow: LR 1000 control for a separate formulation-development stage. This is not a reactor attachment or proof that its sample may be transferred into an evaporator without method review.

Related workflow: MultiDrive basic M20 Successor Package for separately specified dry sample preparation. It is not a solvent mill or an accessory included with this evaporation package.

Ready to specify the Auto complete package?

For the standard US setup: choose catalog 0010007358 when the delivered coated glassware, integrated-control approach and component capabilities fit your method. Review the scope and facility requirements rather than assuming every RV 10 listing is the same complete configuration.

For options or procurement confirmation: tell Blue Tiger the application, typical batch, solvent class, desired mode and receiving/delivery requirements. Ask us to confirm the exact US scope, request current manufacturer availability and dispatch information, and coordinate manufacturer application questions before a time-critical purchase.

Ask about options or availability

Mention RV 10 auto pro V-C Complete and catalog 0010007358. Shipping-weight allowance and automated arrival dates are estimates, not a confirmed manufacturer gross weight or supplier lead time.

Frequently Asked Questions

What is included in US RV 10 Auto Complete package 0010007358?

IKA’s current US scope lists RV 10 auto pro, VACSTAR digital, RV 10.910 coated vertical glassware, H.SI.8 tubing, VSE 1 and RC 2 lite. The exact description also includes the HB digital heating bath. Fluids, a software license, protective cabinet and every possible facility or exhaust accessory are not established as supplied. Confirm the delivered parts before selecting spares.

What does Auto add compared with the Digital Complete kit?

Auto 0010007358 has the TFT interface and integrated vacuum-control approach, with automatic boiling-point detection supported by the matching VACSTAR digital and correct operating conditions. Digital Complete 0010012821 uses an external VC 10 lite controller. Both are complete hardware packages; Auto is not automatically a larger-batch or higher-throughput version.

Does automatic boiling-point detection mean I can leave any sample unattended?

No. The manual requires evaporation processes to be verified before automatic use and says unfamiliar processes must not simply be automated. Correct pump, cooling-flow and temperature setup is required. Foaming, bumping, mixtures and hazardous media still need method-specific safeguards and trained supervision.

Why does cooling setup affect automatic operation?

The drive uses the temperature difference between condenser cooling-water inlet and outlet. Its manual specifies 30–100 L/h measured flow and a constant 18–22°C reference cooling-water range. Reversed inlet/outlet connections can prevent automatic distillation. A chiller’s maximum free-flow or lowest setpoint does not prove that the installed circuit meets these conditions.

Does the 2 mbar pump specification guarantee that process pressure?

No. The 2 mbar figure is the manufacturer’s VACSTAR digital final-pressure specification. Actual process pressure depends on the solvent, vapor load, leaks, temperature and setup. The Auto drive controls the compatible pump through its specified connection; do not add the manual’s separate two-position vacuum valve as if it were the Auto pump arrangement.

Can I treat the 4 L bath or 180°C rating as the sample charge and temperature?

No. Bath capacity is not evaporating-flask charge, and the heating range is not permission to heat every sample or coated glass component to 180°C. The exact kit table and bath manual also differ on maximum fill and power figures. Use the actual bath marks, flask displacement, fluid choice, coated-part limits and delivered instructions.

Is the whole package covered by an unconditional five-year warranty?

No. The current package page states two years standard, with registration extensions described separately: three additional years for the rotary evaporator and bath, and one additional year for pump and chiller. IKA’s applicable registration rules, terms and exclusions govern coverage; this is not a five-year promise for every glass, wear or peripheral part.

Is 21.5 kg the shipping weight, and how will this equipment be delivered?

No confirmed packed kit gross is established by that headline figure. The store uses a documented 190 lb provisional aggregate packing allowance for the complete system, not a claim that it ships as one parcel or that IKA measured that gross. Mainland equipment delivery rates are configured; Alaska/Hawaii freight, territories, international destinations and special services require a quote.

    Product Specifications

    ParameterDetails
    Manufacturer / packageIKA / RV 10 auto pro V-C Complete
    US catalog number0010007358
    Electrical version115 V, 50/60 Hz; verify each component rating plate and facility load
    Drive / interfaceRV 10 auto pro / TFT color graphic interface
    Speed, exact package specification5–280 rpm; do not substitute the broader manual’s 300 rpm limit
    Rotation functionsReversible, interval operation and smooth start as specified
    Lift / strokeMotorized / 140 mm
    Safety liftPower-failure lift-out under the manual’s inspection, configuration and load conditions
    Vacuum controllerIntegrated in Auto system; not a separate VC 10 lite
    Pump suppliedVACSTAR digital, compatible speed-controlled arrangement
    Pump final pressure2 mbar manufacturer component figure, not a guaranteed process pressure
    Automatic boiling-point detectionSupported with matched pump and correct cooling/method setup
    Volume-controlled modeDifferent operating route; requires its own setup/test and efficiency adjustment
    Automatic / volume modesMutually exclusive per drive manual
    Cooling-flow reference for automatic mode30–100 L/h measured flow, not chiller free-flow rating
    Cooling-temperature reference18–22°C constant cooling-water range per drive instructions
    Glassware suppliedRV 10.910 vertical coated set; verify delivered US components before choosing replacement joints
    Condenser cooling surface1,500 cm² in current exact package data
    Evaporating flask reference1,000 mL in the linked glassware installation instructions; actual permitted charge is not the nominal flask volume
    Coated-part service limitsFollow delivered glassware instructions; linked notes give −30 to +60°C for specified Surlyn-coated parts
    Heating bathHB digital, described by IKA as a 4 L water/oil bath
    Bath heating rangeRoom temperature to 180°C, subject to fluid, fill, sample and glassware limits
    Bath maximum fill / electrical powerConflicting package/manual figures not presented as one resolved working-fill or total-system load rating
    ChillerRC 2 lite, R290 refrigeration
    Cooling performance reference400 W manufacturer reference; temperature-dependent, not guaranteed at every setpoint
    Chiller temperature capabilityDown to −10°C per package description; not the recommended setting for every Auto method
    Vapor managementVSE 1 included; install and assess exhaust/ventilation per instructions
    Tubing scopeH.SI.8, as listed in the current US package
    Computer interfacesUSB / RS 232; labworldsoft license not established as supplied
    ProgrammingRamp/program functions under drive instructions; no regulatory-record or unattended-use claim
    Package-table dimensions500 × 430 × 440 mm W × H × D reference; not complete bench footprint or shipping carton size
    Package-table mass21.5 kg reference; not a verified packed complete-system gross
    Use environmentResearch laboratory equipment for trained personnel; applicable component and process limits govern
    ProtectionIP20 drive/package reference; not an explosion-protection rating
    WarrantyStandard two years per current package page; conditional registration extensions differ by component

    Ordering Information

    ParameterDetails
    Order code / Blue Tiger SKU0010007358 / BTS-0010007358
    Order unit1 manufacturer-defined US Auto complete package
    Core scopeRV 10 auto pro, HB digital, VACSTAR digital, RV 10.910, RC 2 lite, VSE 1 and H.SI.8
    Separate requirementsAppropriate fluids, ventilation/exhaust and electrical facilities; software/accessories not supplied unless listed
    Shipping planning basis190 lb provisional aggregate packed-weight allowance; not manufacturer-measured and not one-parcel representation
    Rate assignmentExisting IKA equipment freight profile, mainland coverage; remote freight/territory/international exceptions quoted
    Delivery and stockManufacturer availability, dispatch and actual cartons confirmed separately; automated dates are estimates

    Authorized reseller

    Blue Tiger Scientific is an authorized reseller of IKA products. We handle your purchase and requests to return an order. IKA is the manufacturer and provides manufacturer warranty coverage, technical service, calibration and repairs. Blue Tiger Scientific does not perform these services or determine warranty coverage.

    Shipping and delivery

    Availability, dispatch timing and freight depend on the product and destination. Delivery dates are estimates unless expressly confirmed as binding in writing by IKA. Contact Blue Tiger Scientific for order-specific shipping information.

    Inspect your delivery

    Inspect the equipment and packaging immediately upon receipt. Report damage, missing items or visible defects to Blue Tiger Scientific immediately, retaining photographs, packaging and shipping documents. IKA's terms require written notice of visible defects, shortages or quality deviations no later than seven days after receipt, and notice of hidden defects no later than seven days after discovery. Prompt reporting allows us to forward the information to IKA within its deadlines. Do not use or install equipment found to be defective until instructions are provided.

    Returns must start with Blue Tiger Scientific

    Contact Blue Tiger Scientific before returning any IKA product. Returns are not automatic and require IKA's written approval and an RMA number. We will provide the approved destination and return instructions; do not ship equipment to Blue Tiger or IKA without those instructions.

    IKA's published return conditions require a written return request within 60 days of shipment, and the returned goods must reach IKA within 30 days after the RMA is issued. These are manufacturer approval requirements, not an unconditional 60-day return guarantee.

    Approved returns must be in excellent, resalable condition in the original container. IKA requires its RMA and original invoice information with the return; Blue Tiger will coordinate the required order documentation. Returns not caused by an IKA error are subject to a minimum 15% restocking charge. Inspection may identify additional service or repair charges needed to restore resalable condition. Return freight is normally prepaid by the purchaser. Charges and any applicable cross-border brokerage responsibility will be confirmed with the authorization. IKA states that returns due to its own error receive full credit. Any customer refund is confirmed through Blue Tiger after the return is accepted and the applicable credit is established. Unauthorized returns may be refused and may receive no credit.

    Manufacturer warranty and service

    IKA handles warranty registration, warranty assessment, technical support, repair and calibration directly. Blue Tiger Scientific does not administer or perform manufacturer warranty service. Keep your proof of purchase and serial number, and register the product with IKA within 90 days of purchase to meet its published registration requirements.

    Warranty periods and free extensions depend on the exact product and IKA's applicable terms. No single warranty period or lifetime-warranty claim applies to all IKA products. IKA determines coverage and the applicable remedy, subject to its conditions and exclusions. For any physical return, including equipment requiring manufacturer service, contact Blue Tiger first so the required authorization and routing are confirmed; IKA handles the technical service itself.

    Cleaning before a service shipment

    Equipment sent to IKA for repair must be cleaned, safely decontaminated as applicable, and accompanied by IKA's completed and signed decontamination certificate. IKA states that it cannot process a repair without this document. Follow the specific authorization and packing instructions before dispatch.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.