$73.00

    A hydrometer with an internal thermometer for LPG specific gravity. The Heathrow Scientific LPG Hydrometer measures propane, butane and other light hydrocarbons.

    • Specific gravity 0.500 to 0.650 in 0.001 steps
    • Thermometer 30 to 90°F in 1°F steps; 14.4 in. length
    • Sold as 1 Each (catalog number 67101HTS)

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

A hydrometer with a built-in thermometer for light hydrocarbons

Checking the specific gravity of liquefied petroleum gas usually means reading two things together: the density value and the temperature at which you took it. The Heathrow Scientific Liquid Petroleum Gas (LPG) Hydrometer combines both in one instrument. It measures the specific gravity of LPG such as propane, butane and other light hydrocarbons, and it includes an internal thermometer for temperature measurement.

Manufacturer photograph of the LPG hydrometer 67101HTS with its internal thermometer
Manufacturer photograph of the 67101HTS LPG hydrometer.

What the 67101HTS gives you

  • Specific gravity range 0.500 to 0.650
  • Specific gravity subdivisions of 0.001
  • Internal thermometer, 30 to 90°F, in 1°F subdivisions
  • Safety Blue thermometer liquid fill
  • Length 14.4 in. (365 mm)

Sold as 1 Each.

Reading the scale

The 0.500 to 0.650 range is aimed at the light end of the hydrocarbon family, and the 0.001 subdivisions let you read the scale in fine steps. The internal thermometer spans 30 to 90°F with 1°F subdivisions, so the temperature reading sits alongside the density reading on the same instrument.

Calibrated at a reference temperature

The hydrometer is calibrated for use at 15°C (60°F). Record the temperature shown by the thermometer with each reading and follow your own method or the applicable standard for any correction.

Safety Blue fill

The thermometer contains Safety Blue liquid fill.

Fit to your sampling setup

The hydrometer is 14.4 in. (365 mm) long. Check that your sampling cylinder or apparatus can accommodate that length and the 0.500 to 0.650 range before you order.

If your application requires calibration documentation or a particular reference method, confirm that requirement for 67101HTS before ordering. Follow your site’s procedures for handling pressurized or flammable materials.

Ordering the LPG hydrometer

67101HTS is supplied as 1 Each. Blue Tiger Scientific confirms availability and delivery details with your order.

Frequently Asked Questions

What does this hydrometer measure?

It measures the specific gravity of liquefied petroleum gases such as propane, butane and other light hydrocarbons.

What is the specific gravity range?

0.500 to 0.650, with 0.001 subdivisions.

Does it include a thermometer?

Yes. An internal thermometer covers 30 to 90°F in 1°F subdivisions, with Safety Blue liquid fill.

What reference temperature is it calibrated for?

The calibration temperature is 15°C (60°F).

How long is the hydrometer?

14.4 in. (365 mm).

How can I check suitability for a method that requires a calibration certificate?

Give Blue Tiger Scientific the required standard or certificate details before ordering so documentation for 67101HTS can be confirmed.

How many come in one order?

One. The order unit is 1 Each.

Can I use it for liquids other than LPG?

The 0.500 to 0.650 range is intended for light hydrocarbons. Confirm that your liquid’s expected specific gravity falls within it before ordering.

    SpecificationDetail
    BrandHeathrow Scientific
    ProductLiquid Petroleum Gas (LPG) Hydrometer
    Catalog Number67101HTS
    Quantity1 Each
    TypeLiquid Petroleum Gas (LPG)
    Specific Gravity Range0.500 to 0.650
    Specific Gravity Subdivisions0.001
    Temperature Range30 to 90°F
    Thermometer Subdivisions1°F
    Thermometer Liquid FillSafety Blue
    Calibration Temperature15°C (60°F)
    Length14.4 in. (365 mm)

    Ordering Information

    Cat. No.DescriptionPack
    67101HTSLPG Hydrometer, 0.500–0.650, internal thermometer 30–90°F1 Each

    Heathrow Scientific: Shipping & Return Policy

    At Blue Tiger Scientific, we're proud to offer a wide range of authentic Heathrow Scientific products. Please review the following policies, which apply to all Heathrow Scientific purchases made through our store. Remember, all return requests must be initiated directly with Blue Tiger Scientific.

    Shipping Policy

    Orders for Heathrow Scientific products are fulfilled and shipped straight from Heathrow Scientific's facilities, primarily utilizing reliable carriers like FedEx or UPS. FedEx Ground is the standard shipping method for all orders.


    Heathrow Scientific ships only to residential or business addresses within the United States. We cannot ship to P.O. Boxes.


    Orders placed outside of regular business hours, on weekends, or during holidays will be processed on the next business day, subject to product availability and carrier schedules.


    Delivery times can vary based on the specific product's availability, the overall size of your order, and current carrier logistics.


    Once your order has shipped, Blue Tiger Scientific and Heathrow Scientific are not responsible for unforeseen carrier delays, disruptions due to weather, or other delivery issues beyond our control.


    All shipments are processed on an EX-WORKS (EXW) basis from Heathrow Scientific’s facility. Risk of loss passes to the customer once the product is picked up by the carrier.

    Return Policy

    Should you need to return a Heathrow Scientific product, you must start the process with Blue Tiger Scientific. We will then work directly with Heathrow Scientific to facilitate your return, ensuring you obtain the necessary Return Goods Authorization (RGA) number.

    For domestic orders, products must be returned within 30 days of the order shipment date.

    All returns must include a valid RGA number obtained from Blue Tiger Scientific. If the product isn't received within the stipulated period, the RGA number will be voided. Any item received without a valid RGA number will be returned to the sender.

    Damaged or Missing Goods

    To ensure eligibility for a replacement or refund, all claims for damaged or missing items must be reported within 24 hours of delivery. Failure to report within this timeframe may void your claim due to carrier claim limitations.

    Returns Due to Customer Error or Change of Mind

    If you ordered the wrong product or simply changed your mind:

    The refund is the purchase price less a 20% restocking fee and less the original shipping costs. The product must be unused, in its original, unopened packaging and in resalable condition.

    Once Heathrow Scientific receives the returned product and verifies its condition, a credit will typically be issued to your original payment method within approximately 3 weeks.

    Non-Returnable Items

    Please note the following are non-returnable under any circumstances:

    Items missing accessories, manuals, or packaging will be rejected.

    Products classified as hazardous cannot be returned. Certain items are made to order and are not eligible for return or refund.

    Warranty Information & Registration

    All warranty claims and product registration are handled directly by Heathrow Scientific. Product-specific warranty note: Coverage is subject to the manufacturer’s applicable terms for this specific product. Published equipment warranty periods should not be assumed to apply to this labware or consumable. Retain your invoice or proof of purchase for any manufacturer review.

    For warranty details or to register your product, visit Heathrow Scientific’s Warranty Information & Registration page.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.