Skip to content
SIBATA Class A Glass Burets with PTFE Stopcock 50 mL Heathrow Scientific
SIBATA Class A Glass Burets with PTFE Stopcock 50 mL Heathrow Scientific

SIBATA Class A Glass Burets with PTFE Stopcock

$112.00

    Deliver measured increments of titrant through a PTFE stopcock. Choose a 10, 25 or 50 mL Class A buret, sold individually.

    • Permanent graduation marks on borosilicate tubing
    • 10 mL model has the finest divisions at 0.05 mL
    • 25 and 50 mL models both have 0.10 mL divisions

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Order Now
FIND YOUR FIT

Compare buret capacities and tolerances

Prices apply to the selling unit shown for each configuration. Check the ordering information for package contents.

Available configurations for SIBATA Class A Glass Burets with PTFE Stopcock
Product Catalog No. Configuration Selling unit Price Order
21310-10 BTS-21310-10 10 mL · 0.05 mL divisions; ±0.02 mL 1 buret $112.00 per listed selling unit

21310-25 BTS-21310-25 25 mL · 0.10 mL divisions; ±0.03 mL 1 buret $116.00 per listed selling unit

21310-50 BTS-21310-50 50 mL · 0.10 mL divisions; ±0.05 mL 1 buret $140.00 per listed selling unit

Choose by delivery volume and scale interval

For a manual titration, compare the expected endpoint volume with the buret capacity. A smaller scale interval helps distinguish small changes; a larger capacity can avoid a refill. The 25 and 50 mL burets share a scale interval but not the same tolerance.

The close-up separates the permanent graduated scale from the PTFE flow-control assembly.
The close-up separates the permanent graduated scale from the PTFE flow-control assembly.

Plan clamp and receiver clearance

Mount the buret upright in a suitable clamp with clearance for the tip and receiving vessel. Read the liquid level before and after dispensing; the difference is the delivered volume. The stopcock controls flow, not the volume calculation.

For a receiving vessel that can be swirled beneath the tip, compare the narrow-neck Erlenmeyer flask.

Buyer FAQs

Which model offers the smallest scale interval?

The 10 mL model is divided every 0.05 mL and has a tolerance of ±0.02 mL.

How do the 25 and 50 mL burets differ?

Both have 0.10 mL divisions. Their tolerances are ±0.03 mL and ±0.05 mL respectively.

Is a division the same thing as a tolerance?

No. A division is the gap between adjacent marks; the tolerance specifies the permitted volume error.

Is this buret calibrated to contain or to deliver?

To deliver. Read the starting and ending levels to determine the volume dispensed.

Does the stopcock require a greased glass plug?

No. The supplied stopcock is PTFE rather than a ground-glass plug that requires lubrication.

Does one pack contain all three sizes?

No. One pack contains one buret in the capacity selected.

Would a graduated cylinder perform the same job?

A cylinder measures liquid held in the vessel. The buret combines a delivery scale with a stopcock so you can meter liquid directly into a receiver.

Who handles returns or manufacturer service?

Start returns with Blue Tiger Scientific before shipping. Heathrow Scientific handles manufacturer service, with Blue Tiger coordinating the request.

    SpecificationDetail
    BrandHeathrow Scientific
    SeriesSIBATA 21310
    CalibrationTo deliver (TD)
    GlassBorosilicate
    StopcockPTFE
    ClassificationASTM E287 Class A

    Ordering Information

    Cat. No.DescriptionPack
    21310-1010 mL · 0.05 mL divisions; ±0.02 mL1 buret
    21310-2525 mL · 0.10 mL divisions; ±0.03 mL1 buret
    21310-5050 mL · 0.10 mL divisions; ±0.05 mL1 buret

    Heathrow Scientific: Shipping & Return Policy

    At Blue Tiger Scientific, we're proud to offer a wide range of authentic Heathrow Scientific products. Please review the following policies, which apply to all Heathrow Scientific purchases made through our store. Remember, all return requests must be initiated directly with Blue Tiger Scientific.

    Shipping Policy

    Orders for Heathrow Scientific products are fulfilled and shipped straight from Heathrow Scientific's facilities, primarily utilizing reliable carriers like FedEx or UPS. FedEx Ground is the standard shipping method for all orders.


    Heathrow Scientific ships only to residential or business addresses within the United States. We cannot ship to P.O. Boxes.


    Orders placed outside of regular business hours, on weekends, or during holidays will be processed on the next business day, subject to product availability and carrier schedules.


    Delivery times can vary based on the specific product's availability, the overall size of your order, and current carrier logistics.


    Once your order has shipped, Blue Tiger Scientific and Heathrow Scientific are not responsible for unforeseen carrier delays, disruptions due to weather, or other delivery issues beyond our control.


    All shipments are processed on an EX-WORKS (EXW) basis from Heathrow Scientific’s facility. Risk of loss passes to the customer once the product is picked up by the carrier.

    Return Policy

    Should you need to return a Heathrow Scientific product, you must start the process with Blue Tiger Scientific. We will then work directly with Heathrow Scientific to facilitate your return, ensuring you obtain the necessary Return Goods Authorization (RGA) number.

    For domestic orders, products must be returned within 30 days of the order shipment date.

    All returns must include a valid RGA number obtained from Blue Tiger Scientific. If the product isn't received within the stipulated period, the RGA number will be voided. Any item received without a valid RGA number will be returned to the sender.

    Damaged or Missing Goods

    To ensure eligibility for a replacement or refund, all claims for damaged or missing items must be reported within 24 hours of delivery. Failure to report within this timeframe may void your claim due to carrier claim limitations.

    Returns Due to Customer Error or Change of Mind

    If you ordered the wrong product or simply changed your mind:

    The refund is the purchase price less a 20% restocking fee and less the original shipping costs. The product must be unused, in its original, unopened packaging and in resalable condition.

    Once Heathrow Scientific receives the returned product and verifies its condition, a credit will typically be issued to your original payment method within approximately 3 weeks.

    Non-Returnable Items

    Please note the following are non-returnable under any circumstances:

    Items missing accessories, manuals, or packaging will be rejected.

    Products classified as hazardous cannot be returned. Certain items are made to order and are not eligible for return or refund.

    Warranty Information & Registration

    All warranty claims and product registration are handled directly by Heathrow Scientific. Product-specific warranty note: Coverage is subject to the manufacturer’s applicable terms for this specific product. Published equipment warranty periods should not be assumed to apply to this labware or consumable. Retain your invoice or proof of purchase for any manufacturer review.

    For warranty details or to register your product, visit Heathrow Scientific’s Warranty Information & Registration page.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

SIBATA Class A Glass Burets with PTFE Stopcock

Capacity: 10 mL
Authorized Dealer

Choose by delivery volume and scale interval

For a manual titration, compare the expected endpoint volume with the buret capacity. A smaller scale interval helps distinguish small changes; a larger capacity can avoid a refill. The 25 and 50 mL burets share a scale interval but not the same tolerance.

The close-up separates the permanent graduated scale from the PTFE flow-control assembly.
The close-up separates the permanent graduated scale from the PTFE flow-control assembly.

Plan clamp and receiver clearance

Mount the buret upright in a suitable clamp with clearance for the tip and receiving vessel. Read the liquid level before and after dispensing; the difference is the delivered volume. The stopcock controls flow, not the volume calculation.

For a receiving vessel that can be swirled beneath the tip, compare the narrow-neck Erlenmeyer flask.

Buyer FAQs

Which model offers the smallest scale interval?

The 10 mL model is divided every 0.05 mL and has a tolerance of ±0.02 mL.

How do the 25 and 50 mL burets differ?

Both have 0.10 mL divisions. Their tolerances are ±0.03 mL and ±0.05 mL respectively.

Is a division the same thing as a tolerance?

No. A division is the gap between adjacent marks; the tolerance specifies the permitted volume error.

Is this buret calibrated to contain or to deliver?

To deliver. Read the starting and ending levels to determine the volume dispensed.

Does the stopcock require a greased glass plug?

No. The supplied stopcock is PTFE rather than a ground-glass plug that requires lubrication.

Does one pack contain all three sizes?

No. One pack contains one buret in the capacity selected.

Would a graduated cylinder perform the same job?

A cylinder measures liquid held in the vessel. The buret combines a delivery scale with a stopcock so you can meter liquid directly into a receiver.

Who handles returns or manufacturer service?

Start returns with Blue Tiger Scientific before shipping. Heathrow Scientific handles manufacturer service, with Blue Tiger coordinating the request.

Use this text to share information about your product.

Use this text to share information about your product.

Use this text to share information about your product.

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.