Heathrow Scientific Calcium Chloride Hydrometer | 6611-3 Default Title Heathrow Scientific
Heathrow Scientific Calcium Chloride Hydrometer | 6611-3 Default Title Heathrow Scientific

Heathrow Scientific Calcium Chloride Hydrometer | 6611-3

$31.00

    Read specific gravity and the calcium-chloride freezing-point scale with one purpose-selected hydrometer.

    • Specific gravity 1.000–1.280
    • Freezing-point scale 30 to -40°F
    • 6611-3; 1 each

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Two readings for calcium-chloride solutions

Read specific gravity and the calcium-chloride freezing-point scale with one purpose-selected hydrometer.

Heathrow Scientific Calcium Chloride Hydrometer | 6611-3 — Two readings for calcium-chloride solutions
The 6611-3 hydrometer measures calcium-chloride solutions.

Two readings for calcium-chloride solutions

The 6611-3 combines a specific-gravity scale with a freezing-point scale for calcium-chloride solutions. Choose it when those two outputs match your procedure; a general density instrument does not automatically provide this solution-specific freezing-point scale. The 0.002 specific-gravity divisions and 5°F freezing-point divisions let you check the scale spacing before deciding whether it suits your recording requirement.

Plan the vessel and temperature together

The instrument is approximately 12 inches (305 mm) long. Allow enough vessel depth for it to float freely, and check the cylinder opening rather than choosing a vessel from nominal capacity alone. The hydrometer is calibrated at 60°F (approximately 15°C). Record sample temperature alongside the reading and follow the correction procedure required by your method rather than treating a room-temperature reading as automatically corrected.

Read the liquid surface, not a guessed meniscus

Bring your eye level up until the liquid surface appears as a straight line, then read where it crosses the scale. For an opaque sample, use the method-specific meniscus correction. These handling steps help keep the chosen scale useful; they do not turn the instrument into a digital thermometer or a universal antifreeze tester.

Confirm the order unit

6611-3 — 1 Each.

Related choices for your workflow

Hydrometer Racks – Secure Lab Storage & Drying

Choose a dedicated hydrometer rack when the next need is organized instrument storage rather than another measurement scale.

Heathrow Scientific Wide Range Specific Gravity Hydrometers

Compare general specific-gravity ranges when you do not need a calcium-chloride freezing-point scale.

Frequently Asked Questions

What does 6611-3 measure?

Specific gravity and the freezing-point scale of calcium-chloride solutions.

What is the density range?

1.000 to 1.280 specific gravity, divided in 0.002 increments.

What is the freezing-point range?

30 to -40°F with 5°F divisions.

Is this for every antifreeze mixture?

No. Its solution-specific scale is for calcium chloride; choose the scale for your actual sample chemistry.

At what temperature is it calibrated?

60°F (approximately 15°C). Apply your method’s temperature correction when required.

What vessel clearance should I check?

Allow free flotation and suitable depth for the 12-inch (305 mm) instrument. No vessel-fit guarantee is implied.

What is the order unit?

Catalog 6611-3 is supplied as one hydrometer.

    SpecificationDetail
    BrandHeathrow Scientific
    Product lineVEE GEE
    ApplicationCalcium-chloride solutions
    Specific gravity1.000–1.280; 0.002 divisions
    Freezing-point scale30 to -40°F; 5°F divisions
    Calibration temperature60°F (approximately 15°C)
    Length12 in. (305 mm)

    Ordering Information

    Cat. No.DescriptionPack
    6611-3Calcium Chloride Hydrometer | 6611-31 Each

    Heathrow Scientific: Shipping & Return Policy

    At Blue Tiger Scientific, we're proud to offer a wide range of authentic Heathrow Scientific products. Please review the following policies, which apply to all Heathrow Scientific purchases made through our store. Remember, all return requests must be initiated directly with Blue Tiger Scientific.

    Shipping Policy

    Orders for Heathrow Scientific products are fulfilled and shipped straight from Heathrow Scientific's facilities, primarily utilizing reliable carriers like FedEx or UPS. FedEx Ground is the standard shipping method for all orders.


    Heathrow Scientific ships only to residential or business addresses within the United States. We cannot ship to P.O. Boxes.


    Orders placed outside of regular business hours, on weekends, or during holidays will be processed on the next business day, subject to product availability and carrier schedules.


    Delivery times can vary based on the specific product's availability, the overall size of your order, and current carrier logistics.


    Once your order has shipped, Blue Tiger Scientific and Heathrow Scientific are not responsible for unforeseen carrier delays, disruptions due to weather, or other delivery issues beyond our control.


    All shipments are processed on an EX-WORKS (EXW) basis from Heathrow Scientific’s facility. Risk of loss passes to the customer once the product is picked up by the carrier.

    Return Policy

    Should you need to return a Heathrow Scientific product, you must start the process with Blue Tiger Scientific. We will then work directly with Heathrow Scientific to facilitate your return, ensuring you obtain the necessary Return Goods Authorization (RGA) number.

    For domestic orders, products must be returned within 30 days of the order shipment date.

    All returns must include a valid RGA number obtained from Blue Tiger Scientific. If the product isn't received within the stipulated period, the RGA number will be voided. Any item received without a valid RGA number will be returned to the sender.

    Damaged or Missing Goods

    To ensure eligibility for a replacement or refund, all claims for damaged or missing items must be reported within 24 hours of delivery. Failure to report within this timeframe may void your claim due to carrier claim limitations.

    Returns Due to Customer Error or Change of Mind

    If you ordered the wrong product or simply changed your mind:

    The refund is the purchase price less a 20% restocking fee and less the original shipping costs. The product must be unused, in its original, unopened packaging and in resalable condition.

    Once Heathrow Scientific receives the returned product and verifies its condition, a credit will typically be issued to your original payment method within approximately 3 weeks.

    Non-Returnable Items

    Please note the following are non-returnable under any circumstances:

    Items missing accessories, manuals, or packaging will be rejected.

    Products classified as hazardous cannot be returned. Certain items are made to order and are not eligible for return or refund.

    Warranty Information & Registration

    All warranty claims and product registration are handled directly by Heathrow Scientific. Product-specific warranty note: Coverage is subject to the manufacturer’s applicable terms for this specific product. Published equipment warranty periods should not be assumed to apply to this labware or consumable. Retain your invoice or proof of purchase for any manufacturer review.

    For warranty details or to register your product, visit Heathrow Scientific’s Warranty Information & Registration page.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.