Keep your HI97728 ready for the next nitrate sample
Choose HI93728-01 for 100 tests or HI93728-03 for 300 tests. These genuine Hanna pre-measured powder reagents replenish the nitrate-nitrogen method on the HI97728 Nitrate Photometer. Match the pack to your testing workload without changing the chemistry or measurement range.
High-purity chemicals and factory-measured doses simplify routine preparation. Each packet carries a lot number and expiration date for traceable reagent records. These are reagent packs only; the instrument, cuvettes, caps and CAL Check standards are separate products.
Original HI93728-01 reference photograph of HI93728-0 packets. Printed lot and expiration dates are illustrative, not the supplied stock expiry.
Cadmium reduction chemistry, with a clearly defined reporting basis
Nitrate reacts with the reagent to develop an amber tint. A compatible photometer measures the color intensity. On the HI97728, the method is an adaptation of the cadmium reduction method with a range of 0.0 to 30.0 mg/L (ppm) as nitrate-nitrogen (NO₃–N). This range is not expressed as nitrate ions (NO₃⁻). The manual describes an alternative chemical-form display; keep the reporting basis explicit in your records.
Follow the HI97728 mixing sequence precisely
Zero the instrument with 10 mL of unreacted sample. Add one packet of HI93728-0, replace the stopper and cap, then shake vigorously up and down for exactly 10 seconds. Continue by gently inverting for 50 seconds, avoiding bubbles. The powder will not completely dissolve. The method is technique-sensitive: changing the time or method of shaking can affect the result.
Return the cuvette to the holder in the correct orientation and use the 4 minutes 30 seconds countdown before reading. Follow the complete HI97728 instruction manual for cuvette preparation, measurement sequence and interference guidance; this overview does not replace it.
Select the test count that matches your workload
HI93728-01 supplies enough reagent for 100 tests; HI93728-03 supplies enough for 300 tests. Both use the same HI93728-0 packets. The larger pack increases the number of determinations, not the measurement range. Plan consumption against the expiration date of your supplied stock. CAL Check standards are separate instrument-check products, not sample reagents.
Dangerous Goods: review safety before use and shipment
Hanna classifies both pack sizes as Dangerous Goods and states: “Products classified as Dangerous Goods can only be shipped via ground.” The US HI93728-0 SDS identifies UN 2923, CORROSIVE SOLID, TOXIC, N.O.S. (POTASSIUM DISULFATE, CADMIUM,) MIXTURE; class 8, subsidiary hazard 6.1, packing group II. Consult the full SDS for handling, exposure protection, disposal and transport details. No delivery date, carrier eligibility or shipping-service guarantee is implied.
HI93728-03 manufacturer reference photograph of HI93728-0 packets, lot H166, printed EXP 10/2024. The photographed date is illustrative and does not identify supplied stock expiry.
Frequently Asked Questions
Which instrument is verified for both nitrate reagent packs?
The HI97728 Nitrate Photometer manual explicitly lists HI93728-01 for 100 tests and HI93728-03 for 300 tests. Use the exact method for your instrument rather than assuming compatibility with every Hanna nitrate Checker or photometer.
What is the difference between HI93728-01 and HI93728-03?
Test count: HI93728-01 supplies reagent for 100 tests and HI93728-03 for 300 tests. Both use HI93728-0 powder reagent and the same cadmium reduction chemistry. Neither option includes a photometer.
Is the stated range nitrate-nitrogen or nitrate ions?
The 0.0 to 30.0 mg/L range is expressed as nitrate-nitrogen (NO₃–N), not nitrate ions (NO₃⁻). The HI97728 manual also describes selecting an alternative chemical-form display; always record which reporting basis is used.
How much sample and reagent does each HI97728 test use?
Use 10 mL of sample and one packet of HI93728-0 Nitrate Reagent. Zero with unreacted sample before adding the reagent. Follow the complete method manual for preparation, interferences and measurement.
Should all of the powder dissolve, and how is the reaction timed?
No. The manual states that powder will not completely dissolve. Shake vigorously up and down for exactly 10 seconds, then invert gently for 50 seconds without inducing bubbles. Use the 4 minutes 30 seconds countdown before reading. Mixing technique and timing affect the measurement.
Are cuvettes, CAL Check standards or the meter included?
No. This is reagent-only replenishment. The HI97728 photometer, suitable cuvettes with stoppers and caps, and CAL Check standards are separate products. CAL Check standards check the instrument; they do not replace reagents for sample testing.
What do the lot number and date in the photographs mean?
The manufacturer reference photographs show HI93728-0 packets. Printed lot numbers and expiration dates are illustrative, not a statement of the lot or expiry you will receive. Check the supplied packets and plan usage before their actual expiration date.
Are these reagents classified as Dangerous Goods?
Yes. Hanna classifies both pack sizes as Dangerous Goods and states: “Products classified as Dangerous Goods can only be shipped via ground.” The US HI93728-0 SDS lists UN 2923, CORROSIVE SOLID, TOXIC, N.O.S., class 8 with subsidiary hazard 6.1, packing group II. Read the SDS for complete handling, disposal and transport information; this is not a delivery-time or shipping-service guarantee.