Match the chromium range. Then choose your test supply.
Replenish hexavalent chromium testing with the HI93723 high-range chemistry for your Hanna photometer. Choose HI93723-01 for 100 tests or HI93723-03 for 300 tests: the larger pack changes your test supply, not the analytical range or procedure.
Official Hanna generic reagent artwork, representative of both pack options—not a pack-specific contents photo. Printed lot and expiration dates are illustrative, not supplied-stock dates.
The high-range HI97723 match
HI97723: 0–1000 µg/L (ppb) as Cr(VI), using diphenylcarbohydrazide chemistry. Match the complete reagent code and instrument method: this is not HI93749 low-range chemistry or HI723-25 Checker reagent.
What the chemistry measures
The reaction develops a purple tint proportional to hexavalent chromium in water samples. The HI97723 method adapts the ASTM Manual of Water and Environmental Technology, D1687-92, diphenylcarbohydrazide method. Its primary result is Cr(VI), not total chromium. The instrument can convert the display to chromate or dichromate; keep the reporting basis clear when comparing results.
What arrives—and what stays separate
Each selected pack supplies pre-measured HI93723-0 powder reagent for 100 or 300 determinations. The HI97723 procedure uses one packet per determination. The compatible photometer, cuvettes, stoppers, caps, cleaning accessories and CAL Check standards are separate. Standards verify the instrument; they do not replace sample reagent.
The HI97723 workflow at a glance
Fill a clean cuvette with 10 mL of unreacted sample. Stopper and cap it, align it in the holder and zero the meter. Remove it, add one HI93723-0 packet, replace the stopper and cap, and shake vigorously for about 10 seconds. Return the aligned cuvette and use the 6-minute Read countdown. Follow the full manual for temperature guidance, cuvette handling and the complete sequence.
Check your water-sample matrix
The HI97723 manual lists iron above 1 mg/L as an interference and slight reaction inhibition from mercurous and mercuric ions. For vanadium above 1 mg/L, it instructs waiting 10 minutes before reading to remove that interference. Review the exact method against your sample composition rather than assuming every water, seawater or brine matrix is suitable.
Choose a pack for your workload
Choose the 100-test HI93723-01 pack for a smaller refill or the 300-test HI93723-03 pack for a larger sampling program. One order quantity is one selected pack, not one test. Check the marked lot and expiration date on actual stock and select a supply you can use within its stated life.
Documented photometer fit
Both pack sizes are documented for HI97723, HI83300, HI83305, HI83306 and HI83399. The workflow and range here use HI97723 as the primary reference. When using another documented model, select its matching chromium(VI) high-range method and follow that model’s manual.
Handle the powder with the right protection
The US HI93723-0 SDS identifies a hazardous reagent: harmful if inhaled and causing severe skin burns and eye damage. Avoid breathing dust and use the ventilation, protective gloves, clothing, eye and face protection specified in the SDS. Follow its storage, incompatibility and waste instructions. Hanna classifies these packs as Dangerous Goods for ground shipment only.
Frequently Asked Questions
Which pack size should I choose?
HI93723-01 supplies 100 tests; HI93723-03 supplies 300. Both use the same high-range chemistry and one packet per HI97723 determination. Choose by sampling workload and the marked expiration date, not by an expected change in range.
Does this measure total chromium?
No. The method determines hexavalent chromium, Cr(VI), in water samples. The HI97723 primary range is 0–1000 µg/L as Cr(VI). It is not a total-chromium digestion method.
Is 1000 µg/L the same as 1000 mg/L?
No. The HI97723 high-range limit is 1000 µg/L, equal to 1.000 mg/L as Cr(VI). Keep units and reporting species consistent. Chromate and dichromate conversions are different reporting forms, not the same numeric scale.
Can I substitute low-range or Checker reagents?
No. Match the exact reagent code and instrument method. HI93723 high-range packs are not HI93749 low-range packs or HI723-25 Checker reagents. A common parameter name does not establish reagent interchangeability.
How much sample, mixing and reaction time are required?
For HI97723, zero with 10 mL of unreacted sample, then add one HI93723-0 packet. Shake the closed cuvette vigorously for about 10 seconds and use the 6-minute Read countdown. Use the full manual for alignment and temperature guidance; the listed vanadium interference requires a longer wait.
Which sample interferences should I check?
The HI97723 manual lists iron above 1 mg/L, a vanadium timing requirement above 1 mg/L, and slight inhibition from mercurous and mercuric ions. Confirm the entire matrix against the method. The reagent is not a blanket seawater or brine solution.
Which photometers are documented for these packs?
Both sizes are documented for HI97723, HI83300, HI83305, HI83306 and HI83399. The range and workflow summarized here are for HI97723. Follow the exact matching high-range method for the model you use.
Are the meter, cuvettes and CAL Check standards included?
No. This listing is for reagent packs only. Supply the compatible photometer, cuvettes with stoppers and caps, and other sample-handling accessories separately. CAL Check standards are separate verification products, not consumable sample reagents. Read the linked US SDS before handling the powder.