Hanna HI93753 Chloride Reagents, 100/300 Tests 100 tests | HI93753-01 Photometer Reagents Hanna Instruments
Hanna HI93753 Chloride Reagents, 100/300 Tests 300 tests | HI93753-03 Photometer Reagents Hanna Instruments
Hanna HI93753 Chloride Reagents, 100/300 Tests 100 tests | HI93753-01 Photometer Reagents Hanna Instruments
Hanna HI93753 Chloride Reagents, 100/300 Tests 300 tests | HI93753-03 Photometer Reagents Hanna Instruments

Hanna HI93753 Chloride Reagents, 100/300 Tests

$126.49

    A matched chloride refill for blank-and-sample testing. Keep HI97753 water-sample testing supplied with the complete matched chloride reagent set.

    • HI93753-01: 100 tests; HI93753-03: 300 tests
    • HI97753: 0.0 to 20.0 mg/L as Cl⁻
    • Reagents only; meter, cuvettes and CAL Check standards separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

HANNA PHOTOMETER REAGENTS · HI93753

A matched chloride refill for blank-and-sample testing.

Restock the two-liquid chemistry for your HI97753 chloride photometer. Choose 100 or 300 determinations while keeping the same low-level chloride method, reporting units and two-cuvette workflow.

Official Hanna HI93753 reagent set reference photo
Official Hanna 100-test chloride-set reference photo. Printed lot and expiration dates are illustrative, not the expiration date of supplied stock.

Match the method, not just the element name

HI97753: 0.0 to 20.0 mg/L as Cl⁻. The Mercury(II) Thiocyanate method develops an orange tint and measures chloride ions over 0.0 to 20.0 mg/L as Cl⁻ on the HI97753. Chloride is not free or total chlorine: these reagents do not measure disinfectant residual and are not HI753-25 Checker reagents.

What the selected pack supplies

A complete A/B chloride reagent set for the selected test count. Each determination reacts both a deionized-water blank and a sample, so it consumes 1 mL of A and 1 mL of B in total.

Where this method fits

Designed for low-level chloride checks in water samples within the specified range. For low chloride ion concentrations, rinse the sample cuvette several times with sample first; the manual recommends graduated pipettes for accurately delivering both 10 mL portions. This is not an unrestricted seawater or concentrated-brine claim.

The HI97753 workflow at a glance

Prepare one cuvette with exactly 10 mL of deionized water and a second with exactly 10 mL of sample. Add 0.5 mL of HI93753A-0 to each, stopper and cap, then invert each for about 30 seconds. With a second syringe, add 0.5 mL of HI93753B-0 to each and invert again for about 30 seconds. Insert the reacted deionized-water blank with its cap notch aligned and press Zero for the 2-minute countdown. Once zeroed, replace it with the reacted sample cuvette in the same alignment and press Read.

Check the sample matrix

Intensely colored samples need adequate treatment. Remove large amounts of suspended matter by prior filtration. Neutralize alkaline samples before adding reagents; the sample pH after reagent addition should be about 2.

Choose a pack around your workload

HI93753-01 supplies 100 tests; HI93753-03 supplies 300 tests. The larger pack supplies three times the determinations, not a different measuring range. One order quantity means one complete selected pack. Choose by testing frequency and the lot/expiry markings on supplied stock.

What to have beside the reagent set

Supply the compatible photometer, cuvettes with stoppers and caps, and the measuring/dispensing accessories required by the method separately. Deionized water is also required for the chloride blank. CAL Check standards are separate instrument-verification materials, not replacements for sample reagents.

Handling before you begin

Reagent A is toxic if swallowed and harmful in contact with skin; reagent B causes severe skin burns and eye damage and may corrode metals. Read both US SDS, use the specified protection and arrange appropriate hazardous-waste disposal. Hanna identifies both pack sizes as Dangerous Goods for ground shipment only.

Use the exact-model Method Manual below for the complete procedure, cuvette preparation and temperature guidance. Other documented instruments: HI83300, HI83399. Use the matching method in the manual for your exact instrument.

Frequently Asked Questions

Should I choose 100 or 300 tests?

HI93753-01 supplies 100 tests; HI93753-03 supplies 300 tests. Both are complete reagent sets for the same method. Choose by expected workload and marked expiry dates, not by a different analytical range.

Is chloride the same test as chlorine residual?

No. This method reports chloride ions as Cl⁻, not free or total chlorine disinfectant residual. It is also not the HI753-25 Chloride Checker reagent pack.

Why do I need two cuvettes and deionized water?

The HI97753 zeros a reacted deionized-water blank separately from the reacted sample. Use 10 mL in each cuvette and add both reagents to both. Zeroing untreated sample is not the documented procedure.

How much reagent is consumed per reported chloride test?

Add 0.5 mL of A to each cuvette and then 0.5 mL of B to each. Together, the blank and sample use 1 mL of A and 1 mL of B per determination. Pack test counts refer to this complete workflow.

Where does the two-minute wait belong?

After the additions and mixing, place the reacted deionized-water blank in the HI97753 and use its 2-minute Zero countdown. Then replace it with the reacted sample cuvette and press Read. Follow the manual for cuvette preparation and timing.

Which photometers are documented for HI93753?

Both packs are documented for HI83300, HI83399, HI97753. The procedure and range on this page use HI97753 as the primary reference; follow the exact instrument method when using another model.

Which sample conditions should I check first?

Intensely colored samples need adequate treatment. Remove large amounts of suspended matter by prior filtration. Neutralize alkaline samples before adding reagents; the sample pH after reagent addition should be about 2.

Are the instrument, cuvettes and CAL Check standards included?

No. These are reagent-only packs. Provide the photometer, cuvettes with stoppers and caps, and the method-required sampling and dispensing accessories separately. CAL Check standards are separate instrument-validation materials, not test reagents.

    Product Specifications

    SpecificationDetail
    ParameterChloride concentration
    Reagent formatLiquid HI93753A-0 reagent A and HI93753B-0 reagent B
    MethodAdaptation of the Mercury(II) Thiocyanate Method
    Primary instrumentHI97753
    Range and reporting basis0.0 to 20.0 mg/L as Cl⁻
    Documented instrumentsHI83300, HI83399, HI97753
    Reagent dose0.5 mL each of A and B into each of two cuvettes; 1 mL of each reagent per determination
    Sample and zero preparation10 mL deionized-water blank plus 10 mL sample in separate cuvettes
    Timing on HI977532-minute Zero countdown for the reacted deionized-water blank; then Read sample
    MatrixIntensely colored samples need adequate treatment. Remove large amounts of suspended matter by prior filtration. Neutralize alkaline samples before adding reagents; the sample pH after reagent addition should be about 2.
    Pack contentsA complete A/B chloride reagent set for the selected test count. Each determination reacts both a deionized-water blank and a sample, so it consumes 1 mL of A and 1 mL of B in total.
    Separate requirementsCompatible meter, cuvettes, stoppers, caps, sample/dispensing accessories and CAL Check standards; deionized water for blank
    Shipping limitationDangerous Goods; ground shipment only

    Ordering Information

    Catalog numberComplete reagent pack
    HI93753-01100 tests — complete chloride reagent set
    HI93753-03300 tests — complete chloride reagent set

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.