HANNA PHOTOMETER REAGENTS · HI937521
Track calcium directly, with all three liquids matched.
Keep the calcium method on your HI97752 ready for the next water sample. These 50- and 150-test reagent sets combine buffer, reagent A and reagent B for direct calcium reporting, without confusing the refill with calcium-hardness chemistry.
Official Hanna calcium-set reference photo. Printed lot and expiration dates are illustrative, not the expiration date of supplied stock.
Match the method, not just the element name
HI97752: 0 to 400 mg/L as Ca²⁺. The HI97752 uses an adaptation of the oxalate method and reports 0 to 400 mg/L as calcium ions (Ca²⁺). Calcium concentration is not the same reporting basis as calcium hardness as CaCO₃. These HI937521 sets are not HI93720 calcium-hardness reagents or HI720 Checker refills.
What the selected pack supplies
The selected complete calcium reagent set supplies Buffer Reagent and calcium reagents A and B for the stated test count. It is not a single-bottle refill.
Where this method fits
A practical refill for water programs that specify calcium concentration, including plant-nutrition monitoring where calcium supports cell-wall strength. Check the matrix and required reporting basis rather than treating a calcium number as a hardness result.
The HI97752 workflow at a glance
Select Calcium on the HI97752. Use a 5 mL syringe to add 3 mL of unreacted sample to the cuvette. Add HI93752A-Ca to the 10 mL mark (7 mL), then add 4 drops of Buffer Reagent. Stopper, cap and invert to mix; align the cap notch and zero. Remove the cuvette and add 1 mL of HI93752B-Ca with a 1 mL syringe. Invert 10 times (about 15 seconds). Use the 5-minute countdown; after that wait, invert again 10 times (about 15 seconds), return the aligned cuvette and press Read for the calcium result.
Check the sample matrix
Acidity or alkalinity above 1000 mg/L as CaCO₃ and magnesium above 400 mg/L may interfere. Check those limits before selecting the method for a water matrix.
Choose a pack around your workload
HI937521-01 supplies 50 tests; HI937521-03 supplies 150 tests. The larger pack supplies three times the determinations, not a different measuring range. One order quantity means one complete selected pack. Choose by testing frequency and the lot/expiry markings on supplied stock.
What to have beside the reagent set
Supply the compatible photometer, cuvettes with stoppers and caps, and the measuring/dispensing accessories required by the method separately. CAL Check standards are separate instrument-verification materials, not replacements for sample reagents.
Handling before you begin
Review the US SDS for Buffer Reagent, calcium A and calcium B before use. Follow the specified protection, storage and waste-disposal practices for each liquid. The manual calls the components HI93752A-Ca and HI93752B-Ca; the linked US SDS registry identifies them as HI93752A-0 Ca and HI93752B-0 Ca.
Use the exact-model Method Manual below for the complete procedure, cuvette preparation and temperature guidance. Other documented instruments: HI83300, HI83303, HI83325, HI83399. Use the matching method in the manual for your exact instrument.
Frequently Asked Questions
Should I choose 50 or 150 tests?
HI937521-01 supplies 50 tests; HI937521-03 supplies 150 tests. Both are complete reagent sets for the same method. Choose by expected workload and marked expiry dates, not by a different analytical range.
Is the result calcium or calcium hardness?
The HI97752 reports calcium as Ca²⁺ over 0 to 400 mg/L. These are HI937521 calcium reagents, not HI93720 calcium-hardness reagents, and the result is not expressed as CaCO₃ hardness.
Which liquids does one calcium determination require?
Use 3 mL of sample, 7 mL of calcium reagent A, 4 drops of Buffer Reagent and 1 mL of calcium reagent B. The complete set includes the three reagent components; the meter and glassware are separate.
When should I zero and remix the cuvette?
Zero after adding sample, reagent A and buffer. Add reagent B afterward and invert 10 times, about 15 seconds. After the 5-minute wait, invert another 10 times before the final Read. Follow the full HI97752 method for alignment and timing.
Why do the calcium SDS codes include “-0 Ca”?
The exact HI97752 method names reagent A as HI93752A-Ca and B as HI93752B-Ca. Hanna’s US SDS registry and document headers use HI93752A-0 Ca and HI93752B-0 Ca. The links below identify the actual calcium components, not magnesium reagents.
Which photometers are documented for HI937521?
Both packs are documented for HI83300, HI83303, HI83325, HI83399, HI97752. The procedure and range on this page use HI97752 as the primary reference; follow the exact instrument method when using another model.
Which sample conditions should I check first?
Acidity or alkalinity above 1000 mg/L as CaCO₃ and magnesium above 400 mg/L may interfere. Check those limits before selecting the method for a water matrix.
Are the instrument, cuvettes and CAL Check standards included?
No. These are reagent-only packs. Provide the photometer, cuvettes with stoppers and caps, and the method-required sampling and dispensing accessories separately. CAL Check standards are separate instrument-validation materials, not test reagents.