Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Hanna HI937521 Calcium Reagents, 50/150 Tests Photometer Reagents Hanna Instruments
Hanna HI937521 Calcium Reagents, 50/150 Tests Photometer Reagents Hanna Instruments

Hanna HI937521 Calcium Reagents, 50/150 Tests

$49.49

    Track calcium directly, with all three liquids matched. Keep HI97752 water-sample testing supplied with the complete matched calcium reagent set.

    • HI937521-01: 50 tests; HI937521-03: 150 tests
    • HI97752: 0 to 400 mg/L as Ca²⁺
    • Reagents only; meter, cuvettes and CAL Check standards separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

HANNA PHOTOMETER REAGENTS · HI937521

Track calcium directly, with all three liquids matched.

Keep the calcium method on your HI97752 ready for the next water sample. These 50- and 150-test reagent sets combine buffer, reagent A and reagent B for direct calcium reporting, without confusing the refill with calcium-hardness chemistry.

Official Hanna HI937521 reagent set reference photo
Official Hanna calcium-set reference photo. Printed lot and expiration dates are illustrative, not the expiration date of supplied stock.

Match the method, not just the element name

HI97752: 0 to 400 mg/L as Ca²⁺. The HI97752 uses an adaptation of the oxalate method and reports 0 to 400 mg/L as calcium ions (Ca²⁺). Calcium concentration is not the same reporting basis as calcium hardness as CaCO₃. These HI937521 sets are not HI93720 calcium-hardness reagents or HI720 Checker refills.

What the selected pack supplies

The selected complete calcium reagent set supplies Buffer Reagent and calcium reagents A and B for the stated test count. It is not a single-bottle refill.

Where this method fits

A practical refill for water programs that specify calcium concentration, including plant-nutrition monitoring where calcium supports cell-wall strength. Check the matrix and required reporting basis rather than treating a calcium number as a hardness result.

The HI97752 workflow at a glance

Select Calcium on the HI97752. Use a 5 mL syringe to add 3 mL of unreacted sample to the cuvette. Add HI93752A-Ca to the 10 mL mark (7 mL), then add 4 drops of Buffer Reagent. Stopper, cap and invert to mix; align the cap notch and zero. Remove the cuvette and add 1 mL of HI93752B-Ca with a 1 mL syringe. Invert 10 times (about 15 seconds). Use the 5-minute countdown; after that wait, invert again 10 times (about 15 seconds), return the aligned cuvette and press Read for the calcium result.

Check the sample matrix

Acidity or alkalinity above 1000 mg/L as CaCO₃ and magnesium above 400 mg/L may interfere. Check those limits before selecting the method for a water matrix.

Choose a pack around your workload

HI937521-01 supplies 50 tests; HI937521-03 supplies 150 tests. The larger pack supplies three times the determinations, not a different measuring range. One order quantity means one complete selected pack. Choose by testing frequency and the lot/expiry markings on supplied stock.

What to have beside the reagent set

Supply the compatible photometer, cuvettes with stoppers and caps, and the measuring/dispensing accessories required by the method separately. CAL Check standards are separate instrument-verification materials, not replacements for sample reagents.

Handling before you begin

Review the US SDS for Buffer Reagent, calcium A and calcium B before use. Follow the specified protection, storage and waste-disposal practices for each liquid. The manual calls the components HI93752A-Ca and HI93752B-Ca; the linked US SDS registry identifies them as HI93752A-0 Ca and HI93752B-0 Ca.

Use the exact-model Method Manual below for the complete procedure, cuvette preparation and temperature guidance. Other documented instruments: HI83300, HI83303, HI83325, HI83399. Use the matching method in the manual for your exact instrument.

Frequently Asked Questions

Should I choose 50 or 150 tests?

HI937521-01 supplies 50 tests; HI937521-03 supplies 150 tests. Both are complete reagent sets for the same method. Choose by expected workload and marked expiry dates, not by a different analytical range.

Is the result calcium or calcium hardness?

The HI97752 reports calcium as Ca²⁺ over 0 to 400 mg/L. These are HI937521 calcium reagents, not HI93720 calcium-hardness reagents, and the result is not expressed as CaCO₃ hardness.

Which liquids does one calcium determination require?

Use 3 mL of sample, 7 mL of calcium reagent A, 4 drops of Buffer Reagent and 1 mL of calcium reagent B. The complete set includes the three reagent components; the meter and glassware are separate.

When should I zero and remix the cuvette?

Zero after adding sample, reagent A and buffer. Add reagent B afterward and invert 10 times, about 15 seconds. After the 5-minute wait, invert another 10 times before the final Read. Follow the full HI97752 method for alignment and timing.

Why do the calcium SDS codes include “-0 Ca”?

The exact HI97752 method names reagent A as HI93752A-Ca and B as HI93752B-Ca. Hanna’s US SDS registry and document headers use HI93752A-0 Ca and HI93752B-0 Ca. The links below identify the actual calcium components, not magnesium reagents.

Which photometers are documented for HI937521?

Both packs are documented for HI83300, HI83303, HI83325, HI83399, HI97752. The procedure and range on this page use HI97752 as the primary reference; follow the exact instrument method when using another model.

Which sample conditions should I check first?

Acidity or alkalinity above 1000 mg/L as CaCO₃ and magnesium above 400 mg/L may interfere. Check those limits before selecting the method for a water matrix.

Are the instrument, cuvettes and CAL Check standards included?

No. These are reagent-only packs. Provide the photometer, cuvettes with stoppers and caps, and the method-required sampling and dispensing accessories separately. CAL Check standards are separate instrument-validation materials, not test reagents.

    Product Specifications

    SpecificationDetail
    ParameterCalcium concentration
    Reagent formatLiquid Buffer Reagent plus calcium reagents A (HI93752A-Ca) and B (HI93752B-Ca)
    MethodAdaptation of the Oxalate Method
    Primary instrumentHI97752
    Range and reporting basis0 to 400 mg/L as Ca²⁺
    Documented instrumentsHI83300, HI83303, HI83325, HI83399, HI97752
    Reagent dose4 drops buffer, 7 mL reagent A and 1 mL reagent B per determination
    Sample and zero preparation3 mL sample; add A to the 10 mL mark before buffer and zeroing
    Timing on HI977525 minutes, then invert 10 times (about 15 seconds) before final Read
    MatrixAcidity or alkalinity above 1000 mg/L as CaCO₃ and magnesium above 400 mg/L may interfere. Check those limits before selecting the method for a water matrix.
    Pack contentsThe selected complete calcium reagent set supplies Buffer Reagent and calcium reagents A and B for the stated test count. It is not a single-bottle refill.
    Separate requirementsCompatible meter, cuvettes, stoppers, caps, sample/dispensing accessories and CAL Check standards

    Ordering Information

    Catalog numberComplete reagent pack
    HI937521-0150 tests — complete calcium reagent set
    HI937521-03150 tests — complete calcium reagent set

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.