Keep your HI97746 supplied for low-range iron measurements without confusing packet counts with reportable tests.
Select the documented iron low range method for this reagent.
Swipe or use the arrows to browse.
Keep low-range iron testing moving with the right refill for your HI97746 photometer. Choose HI93746-01 for 50 determinations or HI93746-03 for 150. Each determination uses two packets: one for a reagent blank and one for the water sample—not one packet per result.
The HI97746 measures 0.00 to 1.60 mg/L as Fe using TPTZ chemistry, which develops a violet color. Match the reagent code and method rather than selecting by the word iron alone: these are not HI746 Checker reagents or the HI93721 high-range iron chemistry.
Use for the method's colorimetric determination of iron in water samples. The HI97746 manual specifies sample pH between 3 and 4 and lists metal-ion and nitrite interferences; for example, copper above 0.6 mg/L and cobalt above 0.05 mg/L can interfere. Review the complete interference list for your matrix before relying on a result. Do not assume a general seawater, wastewater or total-digestion application from the reagent name.
HI93746-01 supplies 50 tests; HI93746-03 supplies 150 tests using the same HI93746-0 chemistry. Choose by the number of results you expect to report within the supplied reagent's shelf life. A larger pack does not increase the measuring range. Order quantity 1 for one selected reagent pack.
These are reagent-only refills. Have the HI97746 photometer, clean cuvettes with the specified caps and stoppers, graduated mixing cylinders and deionized water available separately. CAL Check standards are separate instrument-check products, not the reagent blank and not a replacement for sample reagent.
For the HI97746 procedure, prepare 25 mL of deionized water with one HI93746-0 packet and shake vigorously for 30 seconds; transfer 10 mL of this blank to the cuvette and zero. In another cylinder, prepare 25 mL of sample with the second packet and the same mixing step. Transfer 10 mL of reacted sample and use the instrument's 30-second countdown before reading. Follow the linked method manual for the full sequence, temperature guidance and interferences.
Use clean, dry cuvette exteriors and remove bubbles before inserting a cuvette. Observe the method timing and discard the reacted sample promptly after measurement. Check the lot and expiration markings, and review the US Safety Data Sheet before handling or disposal. Hanna classifies these reagents as Dangerous Goods for ground shipment only.
The HI97746 procedure consumes two HI93746-0 packets for each determination: one in a deionized-water blank and one in the sample. Current US retail packs and the HI97746 manual specify HI93746-01 as 50 tests and HI93746-03 as 150 tests. Packet counts must not be treated as test counts.
No. Both packs use the same TPTZ chemistry. On HI97746 the range is 0.00 to 1.60 mg/L as Fe; pack size changes the number of determinations, not the range.
Not for the HI97746 procedure. Prepare a separate blank from 25 mL of deionized water plus one packet, mix as directed and transfer 10 mL to the cuvette for zeroing. The sample is prepared separately with another packet.
The HI97746 iron low-range photometer. Its method manual explicitly lists both pack codes. If using another Hanna photometer, confirm HI93746 chemistry and the exact procedure in that instrument's manual rather than assuming all iron methods are interchangeable.
No universal matrix claim applies. The HI97746 method requires sample pH between 3 and 4 and lists interferences including copper, cobalt, nickel, nitrite and other ions at stated concentrations. Read the complete manual for your sample; marine or complex matrices need method-specific assessment.
The HI97746 meter, cuvettes, caps, stoppers, mixing cylinders, deionized water and CAL Check standards are not part of these reagent refills. Have the accessories required by the method available before testing.
Prepare the blank and sample separately, shaking each vigorously for 30 seconds. After the reacted sample is placed in the meter, use the 30-second reading countdown. The manual gives the complete sequence and temperature-related timing guidance.
Check the catalog code, packet lot and expiration markings and condition of the packaging. Review the HI93746-0 US Safety Data Sheet and follow your handling and waste procedures. Hanna specifies ground shipment for these Dangerous Goods reagents.
At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
For eligible Accucold / Summit equipment. White glove and inside delivery are not included and are quoted separately. Shipping availability and final freight are confirmed with your quote, including Alaska, Hawaii and mixed-product requests.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.
Which would you like to open?
Review items for online purchase.
Review items and request a quote.
Your two carts stay separate. Nothing is moved or combined.