Matched replenishment for ammonia high range testing
Keep high-range water-sample testing supplied with the matched A and B liquid chemistry rather than a low- or medium-range reagent substitute.
Choose HI93733-01 for 100 tests or HI93733-03 for 300 tests. Both pack sizes supply the same method chemistry. Each bottle is marked with its lot number and expiration date for traceability; high-purity, pre-made reagents help streamline sample preparation.
Manufacturer reference packaging. Labels, lot numbers and printed expiration dates are illustrative, not the dates of supplied stock.
The right chemistry, range and reporting basis
The Nessler method produces a yellow tint when ammonia reacts with the reagents. On the HI97733, the primary result is displayed as ammonium (NH₄⁺); its Chemical Form function can convert the display to ammonia nitrogen (NH₃-N) or ammonia (NH₃).
The HI97733 method covers 0.0 to 100.0 mg/L (ppm) as ammonium (NH₄⁺). This is the HI93733 high-range A/B reagent set, not HI93700 low-range, HI93715 medium-range or HI93764B pre-dosed vial chemistry. Hanna classifies these packs as Dangerous Goods for ground shipment only.
A method-specific HI97733 workflow
For the HI97733 method, add 1 mL of unreacted sample to a cuvette with a 1 mL syringe. Add 9 mL of HI93733B-0 to the 10 mL mark, fit the stopper and cap, and invert five times. Zero the meter with this mixture. Add four drops of HI93733A-0, close and invert five times again, then use the 3-minute 30-second measurement countdown. Follow the manual for the full sequence, chemical-form selection and interferences.
Keep cuvettes clean, dry on the outside and free of fingerprints and bubbles. Review all linked Safety Data Sheets before use, wear suitable protection and follow the full method instructions for safe handling and disposal.
What is included — and what is separate
The selected pack provides ammonia high range reagent for 100 or 300 tests. The method uses HI93733A-0 reagent A and HI93733B-0 reagent B. The meter, cuvettes, stoppers, caps, sample-preparation accessories and CAL Check standards are sold separately. These sample reagents are not calibration or CAL Check standards.
Documented instrument compatibility
The source-backed reagent map lists both pack sizes for HI83300, HI83303, HI83305, HI83306, HI83308, HI83314, HI83325, HI83399, HI97733. Select the matching method and follow the manual for your exact model; the HI97733 procedure and range above should not be assumed identical on every instrument.
Choose the pack that fits your workload
HI93733-01 supplies 100 tests for lower-volume replenishment; HI93733-03 supplies 300 tests for a larger sampling workload. Pack size changes the number of tests, not the measurement range. Consider expected use and the expiration dates on the supplied reagents before ordering.
Frequently Asked Questions
Which pack size should I order?
HI93733-01 provides 100 tests and HI93733-03 provides 300 tests with the same method chemistry. Choose the test count to match your workload and use reagents within their marked expiration dates.
Which Hanna instruments are documented for these reagents?
Both packs are listed for HI83300, HI83303, HI83305, HI83306, HI83308, HI83314, HI83325, HI83399, HI97733. Use the exact instrument method; no blanket compatibility with all Hanna meters is claimed.
What range and chemical form are reported?
On HI97733, the method covers 0.0 to 100.0 mg/L (ppm) as ammonium (NH₄⁺). The HI97733 primary display is ammonium, not a 100 mg/L ammonia-nitrogen range. Use Chemical Form to display converted ammonia nitrogen (NH₃-N) or ammonia (NH₃). Other instruments may use a different reporting basis.
How much sample and reagent does the method use?
For HI97733, use 1 mL of sample and 9 mL of HI93733B-0 reagent B. Zero that mixture, then add four drops of HI93733A-0 reagent A. This is a liquid A/B procedure, not a powder-packet or pre-dosed-vial method.
How do I mix and time the reaction?
Invert five times after adding reagent B, then again after reagent A. The HI97733 measurement countdown is 3 minutes 30 seconds. Follow the complete manual, including cuvette preparation and timing guidance.
Are these interchangeable with other reagents or CAL Check standards?
This is the HI93733 high-range A/B reagent set, not HI93700 low-range, HI93715 medium-range or HI93764B pre-dosed vial chemistry. Hanna classifies these packs as Dangerous Goods for ground shipment only. These react with actual samples; CAL Check standards are separate instrument-verification products, not substitute sample reagents.
Does the pack include a meter or cuvettes?
No. This is reagent-only replenishment. The compatible photometer, cuvettes, stoppers, caps and sample-handling accessories are separate. Have the accessories specified in your exact method ready before testing.
What should I check before handling and storage?
Review the linked US Safety Data Sheets for both liquid components and the exact instrument manual. Check lot number and expiration date on each bottle; the photographed packaging dates are illustrative, not the dates of supplied stock. Both pack sizes are Dangerous Goods for ground shipment only.