Ready your HI97717 for the next water sample
Replenish phosphate high range testing without replacing your photometer. Choose HI93717-01 for 100 tests or HI93717-03 for 300 tests; both supply the same matched chemistry for the HI97717 method. The instrument, cuvettes and CAL Check standards are sold separately.
Hanna prepares these reagents with high-purity chemicals and marks each bottle and packet with a lot number and expiration date. The larger pack supports a greater testing workload without changing the analytical method.
Manufacturer reference packaging. Bottle and packet appearance, lot numbers and printed dates are illustrative, not the expiration date of supplied stock.
Choose chemistry and reporting units together
The amino acid method develops a blue tint in the sample. A compatible photometer measures that color to determine phosphate concentration.
The HI97717 method covers 0.0 to 30.0 mg/L as phosphate (PO₄³⁻). The HI97717 primary result is phosphate (PO₄³⁻), not phosphorus (P). Its Chemical Form menu can display phosphorus or phosphorus pentoxide (P₂O₅); retain the correct chemical basis when recording or comparing results.
What your selected pack supplies
Each option is a reagent-only set for the stated test count: liquid reagent a plus powder reagent b. The HI97717 procedure consumes 10 drops of HI93717A-0 and 1 packet of HI93717B-0 per determination. Have a compatible meter, clean cuvettes with stoppers and caps, and the required sample-handling accessories ready separately. CAL Check standards check instrument performance; they do not react with actual samples in place of these reagents.
Follow the HI97717 method sequence
Zero the HI97717 using 10 mL of unreacted sample. Remove the cuvette, add 10 drops of HI93717A-0 and one packet of HI93717B-0, then stopper and cap it. Shake gently until the powder is completely dissolved. Return the cuvette to the meter and start the 5 minute countdown before reading.
Keep the cuvette exterior clean and dry, exclude bubbles and follow the complete linked method manual for interference information and handling guidance. Review both US Safety Data Sheets before use and follow appropriate disposal procedures.
Select a pack for your testing workload
HI93717-01 provides enough reagent for 100 tests, while HI93717-03 provides enough for 300 tests. Balance expected usage against the expiration date on your supplied stock. Manufacturer photos show reference packaging; any old printed expiration dates are illustrative and do not describe the stock you will receive.
Confirm your instrument and method
In addition to HI97717, the mapped Hanna manuals explicitly list these reagent packs for HI83300, HI83303, HI83305, HI83306, HI83308, HI83325, HI83399. Use the complete method for your exact instrument rather than transferring timings or ranges between models.
This is one combined high range method set: liquid A and powder B are used together, not as alternative methods. It is not the low range HI93713 chemistry or HI713-25 Checker reagents. Hanna marks both pack sizes as Dangerous Goods for ground shipment only.
Frequently Asked Questions
What changes between HI93717-01 and HI93717-03?
The test capacity: HI93717-01 supplies 100 tests and HI93717-03 supplies 300 tests. Both are the same matched reagent chemistry; the larger pack does not expand the measurement range.
What is the range and reporting basis on HI97717?
The HI97717 method range is 0.0 to 30.0 mg/L as phosphate (PO₄³⁻). The HI97717 primary result is phosphate (PO₄³⁻), not phosphorus (P). Its Chemical Form menu can display phosphorus or phosphorus pentoxide (P₂O₅); retain the correct chemical basis when recording or comparing results.
Are these liquid reagents or powder packets?
The set contains liquid reagent a plus powder reagent b. For each HI97717 determination use 10 drops of HI93717A-0 and 1 packet of HI93717B-0. The liquid and powder are complementary components of one method, not separate alternatives.
How do I prepare and time the sample?
Zero the HI97717 using 10 mL of unreacted sample. Remove the cuvette, add 10 drops of HI93717A-0 and one packet of HI93717B-0, then stopper and cap it. Shake gently until the powder is completely dissolved. Return the cuvette to the meter and start the 5 minute countdown before reading. Consult the full manual for the complete procedure and interferences.
Which Hanna photometers are supported?
The verified manual map lists HI97717, HI83300, HI83303, HI83305, HI83306, HI83308, HI83325, HI83399. Check the exact instrument method before ordering; do not infer compatibility with all Hanna meters or Checker models.
Does the pack include a meter, cuvettes or CAL Check standards?
No. These are reagent-only replenishment packs. The HI97717 or another explicitly compatible photometer, cuvettes, stoppers, caps and CAL Check standards are separate products. CAL Check standards do not replace sample reagents.
Can I substitute a different range or reagent family?
This is one combined high range method set: liquid A and powder B are used together, not as alternative methods. It is not the low range HI93713 chemistry or HI713-25 Checker reagents. Hanna marks both pack sizes as Dangerous Goods for ground shipment only.
What should I know about traceability, safety and shipping?
Check each supplied bottle and packet for its lot number and expiration date, and review both component US Safety Data Sheets in Manuals/Brochures. Reference photo dates are illustrative, not current stock dates. Hanna classifies both packs as Dangerous Goods for ground shipment only.