(833) 928-4437
Ammonium/TAN by ion-selective electrode in an IP57 handheld kit.
Preparing Quote Cart. Your shopping cart stays unchanged.
Apera AI4654 1000 ppm Ammonium Ion Calibration Solution, 8 oz matches the named analyte.
Swipe or use the arrows to browse.
APERA INSTRUMENTS / ION400-NH / AI4325
The ION400-NH measures ammonium (NH₄⁺) and total ammonia nitrogen (TAN) directly in aqueous samples with Apera’s IndSen 2071M-NH-TS combination electrode, which has a built-in temperature sensor. The electrode covers 0.18 to 9,000 mg/L, and the meter reads in pX, mol/L, ppm or mg/L, with mV and temperature. Apera lists wastewater treatment, environmental monitoring, fertilizer management and research among its uses.
The kit includes four NH₄⁺-N calibration standards and TISAB-D ionic strength adjuster. The meter recognizes the electrode automatically, is IP57 rated and runs on four AA batteries.
Pick the ion first, then decide whether you also need pH. ION400 kits measure ion, mV and temperature; PION400 kits add pH with a second electrode. Each card opens that product page.
AI4356
Potassium (K⁺)
IndSen 2071M-K-TS electrode with four K⁺ standards and TISAB-D.
AI4364
Potassium (K⁺) + pH
Adds the 201T-S pH electrode and three pH buffers.
AI4325
Ammonium (NH₄⁺) / TAN
IndSen 2071M-NH-TS electrode with four NH₄⁺-N standards and TISAB-D.
AI4333
Ammonium (NH₄⁺) / TAN + pH
Kit list follows Apera’s ION400-NH product page.
The IndSen electrode uses an ultra-firm PVC membrane with a solid, non-volatile electrolyte; Apera states this gives two to three times the life of an ordinary PVC electrode. The reference is double-junction with a silver-ion-free gel, the housing is 16 mm and IP67 rated, and a 30 kΩ NTC thermistor in the body feeds automatic temperature compensation.
It can be stored dry. Before measuring, soak it 5 to 10 minutes to pre-condition. Apera rates it at 90% response in 10 seconds and a stable reading about 2 minutes after immersion, with a slope of 54 ± 5 mV at 25°C, an operating range of 5–50°C and sample pH of 2.0–8.5.
The meter supports one- to three-point calibration with guided prompts and shows the electrode slope afterwards. The kit’s 1, 10 and 100 ppm NH₄⁺-N standards cover three points; choose the points that bracket your samples.
The meter flags calibration solution errors and aging electrodes, and displays the slope so you can judge electrode condition before measuring.
Besides K⁺ and NH₄⁺, the meter is preconfigured for Ca²⁺, NO₃⁻, Cu²⁺, F⁻, Na⁺, Cl⁻, Br⁻, I⁻, Ag⁺, S²⁻, Pb²⁺, Cd²⁺ and Hg²⁺, plus user-defined “Ion X” settings, so it can run other Apera ion-selective electrodes.
The electrode senses only the ammonium ion. In basic water ammonium converts to free ammonia (NH₃), which an ammonium ISE cannot detect: Apera notes about 15% is NH₃ at pH 8.5, and above pH 9 readings come out falsely low. Below pH 6, about 99.9% is NH₄⁺.
When sample pH is above 6.0, Apera’s procedure adds TISAB-D at 10 mL per 100 mL of sample, which usually brings it to pH 4–5; add it to the standards at the same 10% ratio. The kit standards are labeled as NH₄⁺-N, the unit most permits use for TAN. Report NH₄⁺-N/TAN with a molecular weight of 14, or NH₄⁺ with 18, without recalibrating; 1 mg/L NH₄⁺-N equals 1.29 mg/L NH₄⁺. See Apera’s ammonia and TAN guide.
Ion concentration reads 0.00–10.00 pX at 0.01 pX resolution, ±1.0% F.S ±1 digit; mV reads −1000 to 1000 mV, ±0.2% F.S ±1 digit; temperature reads 0–100°C at 0.1°C, ±0.5°C ±1 digit.
The meter measures 86 × 196 × 33 mm, weighs 331 g, runs on four AA batteries and is IP57 rated against dust and water. The IndSen 2071M-NH-TS covers 0.18–9,000 mg/L (ppm); 1 × 10⁻⁵ to 0.5 mol/L; 5.0–0.3 pNH₄, with a 1 m cable and 8-pin connector.
The same meter platform comes as ION400-K (AI4356), PION400-K (AI4364) and PION400-NH (AI4333). ION400 kits measure ion, mV and temperature; PION400 kits add pH with the 201T-S electrode and buffers. Choose by the ion you report and whether you also need pH from the same handheld.
Ammonium ion concentration, mV and temperature. Ion results display in pX, mol/L, ppm or mg/L.
The IndSen 2071M-NH-TS electrode covers 0.18–9,000 mg/L (ppm); 1 × 10⁻⁵ to 0.5 mol/L; 5.0–0.3 pNH₄.
No. Apera states it can be stored dry. Soak it 5 to 10 minutes to pre-condition before measuring.
1, 10 and 100 ppm NH₄⁺-N standards (50 mL each), a 1000 ppm NH₄⁺-N standard (100 mL) and 50 mL of TISAB-D.
Both. The electrode senses NH₄⁺; the meter reports NH₄⁺-N/TAN with a molecular weight of 14 or NH₄⁺ with 18, with no recalibration needed to switch. 1 mg/L NH₄⁺-N equals 1.29 mg/L NH₄⁺.
Ammonium converts to free ammonia (NH₃) as pH rises, and the electrode cannot detect NH₃. Apera adds TISAB-D at 10 mL per 100 mL when sample pH is above 6.0, bringing it to about pH 4–5.
Yes. It is preconfigured for 15 ions and accepts user-defined “Ion X” settings, with automatic electrode recognition.
Apera ships the instruction manual in the kit but does not publish it online. Contact us and we will request a copy.
Apera’s limited warranty covers the meter for three years and the probes for six months from delivery, excluding accidental damage, improper use, normal wear and the other causes in Apera’s terms. Warranty service is handled through Apera; returns are coordinated with Blue Tiger Scientific.
Review ION400-NH AI4325 against the ion and range you report, whether you need pH from the same meter, and the standards you will keep on hand. Return to the live price and ordering controls when the configuration fits your work.
APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of THREE YEARS for the instrument (SIX MONTHS for the probes) from the delivery.
This limited warranty does NOT cover any issues due to:
The ION400-NH instruction manual ships printed in the kit; Apera does not publish it online. For a copy before you order, or help with setup and calibration, contact Blue Tiger Scientific and we will request it from Apera.
Apera’s guide to ammonia, ammonium and TAN reporting: Confused by ammonia, ammonium and nitrogen?
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
For eligible Accucold / Summit equipment. White glove and inside delivery are not included and are quoted separately. Shipping availability and final freight are confirmed with your quote, including Alaska, Hawaii and mixed-product requests.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.
Which would you like to open?
Review items for online purchase.
Review items and request a quote.
Your two carts stay separate. Nothing is moved or combined.