Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments

Apera GroStar GS4 Gen II pH/EC/ppm Kit (AI104G)

$184.00

    pH and feed-strength checks in one replaceable-probe pen. GroStar GS4 Gen II combines its model-specific sensor setup with a practical calibration routine and TruRead session summaries.

    • Liquid pH, EC and calculated 500/700 ppm scales
    • GS4-E / AI804G replaceable configuration
    • pH 4/7, 2.77 EC, KCl and four AAA batteries supplied

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA GROSTAR / GS4 / GEN II / AI104G

pH and feed strength.
One grow-room pen.

GS4 Gen II combines a double-junction pH sensor with titanium conductivity sensing in one replaceable probe. Switch between pH, EC and the 500/700 ppm scales, with temperature displayed and TruRead session statistics available.

Choose GS4 for liquid pH plus conductivity-based feed checks. Its standard GS4-E is a solution probe, not a soil spear; ORP needs a separately purchased GS5-E.

Apera GroStar GS4 manufacturer product photograph
Manufacturer reference photograph. Use the Gen II guide for current controls; image revisions may differ.

pH + EC

One replaceable combo probe

Double-junction pH and titanium EC

500 / 700

Two derived ppm scales

No extra nutrient sensors

TruRead

Stable-reading sessions

Average, maximum and minimum

Find your GroStar modelClick or tap to compare all 6 modelsChoose a model below - click or tap here to close

ONE SOLUTION. DIFFERENT CONVERSION SCALES.

1300 ppm or 1820 ppm?
Both can be the same solution.

Start with the conductivity. Apera’s worked example uses 2.6 mS/cm. The 500 and 700 displays apply different multipliers to that same EC; changing the scale does not change the nutrient solution.

2.6 mS/cm

The measured EC

1300 ppm

500 scale: 2.6 × 500

1820 ppm

700 scale: 2.6 × 700

Match the feed chart’s scale, or compare EC directly. This is a conversion example, not a recommended feed strength or dosing target.

What arrives with AI104G?

GS4 pen with GS4-E pH/EC combo probe and cap, pH 4.00 and 7.00 buffers (50 mL each), 2.77 EC standard (50 mL), 3M KCl soaking solution (10 mL), four installed AAA batteries, lanyard and instructions.

The supplied-fluid list is separate from optional compatibility: pH 10.01 and any optional ORP head are separate.

Manufacturer GS4 kit or supplied-probe reference
Manufacturer contents reference. Outer packaging can vary; the text checklist identifies the supplied working items.

WHAT THIS MODEL IS BUILT TO ANSWER

Where GS4 belongs in the routine.

Reservoir and feed checks

Use pH and EC as separate pieces of information. EC reflects the combined ions; pH describes acidity. Neither alone identifies individual nutrients.

One routine, two calibrations

Use pH buffers for the glass sensor and 2.77 EC standard for conductivity. Do not substitute a pH buffer for EC calibration.

Consistent ppm comparisons

Match the scale on the feed chart. A higher number after switching from 500 to 700 is not evidence that the nutrient solution became stronger.

Choose the contact, not just the model number.

Supplied probe: GS4-E / AI804G. The standard head combines double-junction glass pH and titanium EC sensing; the two ppm scales are calculated from EC.

Replaceability gives the worn sensor a maintenance path; it is not an unlimited service-life guarantee. Install, condition and calibrate the correct head according to its instructions.

GroStar GS4 supplied sensing probe detail
Sensing surfaces and care instructions are probe-specific.

A SESSION SUMMARY, NOT A CLOUD LOGGER

Read several spots.
See the spread, not just one number.

In the documented Gen II TruRead workflow, a reading that has stayed stable for seven seconds is recorded for the session. Review the average, maximum and minimum after collecting your measurements. Seven seconds of stability is not the same as a fixed seven-second sampling interval.

6.2 pH

Illustrative minimum

6.3 pH

Illustrative average

6.4 pH

Illustrative maximum

The three illustrative values explain the summary; they do not prescribe a fixed sample count. The reviewed instructions do not establish retained history, timestamps or export. Use a suitable logger if those are requirements.

Calibrate the sensor you are actually using.

Complete pH 7.00 then 4.00 calibration without switching off, and perform the separate EC calibration at 2.77 EC. pH 10.01 is optional; a third recognized pH point is not an included bottle.

Rinse

Rinse between standards and samples to limit carryover. Remove excess water and bubbles, then wait for stability.

Check

Use fresh, correct standards. A calibration reminder or electrode-condition display supports the routine; it does not replace checking the method.

The right routine, shown by Apera.

Watch the manufacturer’s family tutorial alongside the current Gen II manual. The video is a practical family reference, not proof that every photographed control or accessory is identical across revisions.

Rinse water is not automatically storage liquid.

For regular use, keep the combo probe in a tightly closed humid cap. For longer storage, follow GS4’s 3M KCl cap-fill instructions, never immersion storage in pure water. Rinse without rubbing the glass. Keep pH-only sample conditioning separate from EC measurements.

pH is slow in very low-ionic water

Allow stabilization and use the appropriate method. Do not add KCl to a reservoir or an aliquot you will then measure for EC; added salt changes conductivity.

The ppm number changes when the mode changes

Check whether the display is on the 500 or 700 scale. Use the same scale throughout a comparison, or compare EC directly.

Read the slope, not a “life remaining” gauge.

The pH condition figure shown after calibration describes electrode response. It is not a battery indicator, soil-health score or guaranteed percentage of service life left. Use the manual’s cleaning, conditioning and calibration checks before deciding whether to replace the probe.

Calibration markers remind you about the routine. Their disappearance after the documented reminder period is not evidence that the pen has automatically erased calibration.

When a separate field-meter format makes more sense.

If the job is a cabled-probe water-testing workflow rather than a pocket grower pen, compare the alternatives below. These are separate instruments, not plug-in accessories or direct-soil replacements for GS4.

Alternative format: Hanna HI99300 portable liquid EC/TDS meter

Related workflow: Hanna HI98195 portable water pH/ORP/EC meter

GS4 buying and ownership questions

What comes in GS4 AI104G?

The kit supplies GS4 with GS4-E combo probe, pH 4.00/7.00 buffers, 2.77 EC standard, KCl soaking solution, four installed AAA batteries, lanyard and instructions. The GS5-E ORP probe and pH 10.01 buffer are separate.

What does the 5-in-1 description mean?

It counts pH, EC, 500ppm, 700ppm and temperature readouts. The two ppm scales derive from conductivity; they are not two independent nutrient-concentration sensors.

Can GS4 measure ORP as supplied?

The base kit does not include an ORP head. Current Gen II instructions support the separately sold GS5-E; exchange the probe for ORP. GS4-P supplies that additional probe in the kit.

Can I insert GS4 directly into soil?

The standard GS4-E is a liquid pH/EC combo probe, not the GS2 soil spear. Choose a proper sample method and compatible soil configuration rather than forcing this probe into growing media.

How do the two calibration routines differ?

pH uses pH 7.00 followed by 4.00, with optional 10.01. Conductivity uses a single 2.77 EC calibration point. EC calibration also underpins the calculated ppm scales.

Which ppm scale should I follow?

Use the scale specified by the feed chart or compare EC. At 2.6 mS/cm the readings are 1300 ppm500 or 1820 ppm700 for the same solution; changing scale does not change the solution.

Does the electrode-condition percentage show remaining life?

It reports pH electrode slope after calibration, not a guaranteed life percentage or the condition of the EC element. Cleaning, conditioning and recalibration checks come before assuming a replacement is needed.

What is the correct GS4 care routine?

Use the model’s humid-cap and longer-term KCl directions, rinse between samples and do not rub the glass. Do not store immersed in pure water or add KCl to an EC sample or nutrient reservoir as a general stabilization trick.

Choose the measurement.
Confirm the supplied probe.

Review the GS4 kit and specifications, then return to the price and ordering controls. Blue Tiger Scientific can help you match the measurement, sensor and routine before ordering.

Back to price and ordering ↑
    SpecificationDetail
    Brand / familyApera Instruments / GroStar
    Model / catalog numberGS4 / AI104G
    GenerationGen II; current base-pen guide linked below
    Supplied probe configurationGS4-E / AI804G
    Probe replacementReplaceable
    As-supplied measurementpH, EC, 500ppm, 700ppm and temperature
    pH range0.0-14.0 pH
    pH resolution0.1 pH
    pH accuracy±0.1 pH
    pH calibrationAutomatic 1-3 recognized points; follow at least 7.00 then 4.00 routine
    Supplied pH buffers7.00 and 4.00; 10.01 separate
    EC range0-10.0 EC (mS/cm)
    EC resolution0.1 EC
    EC accuracy±0.1 EC
    500ppm scale0-5000 ppm; 10 ppm resolution; ±30 ppm accuracy
    700ppm scale0-7000 ppm; 10 ppm resolution; ±40 ppm accuracy
    ppm conversionEC in mS/cm ×500 or ×700
    EC calibrationOne point at 2.77 EC
    Supplied EC standard2.77 EC (2.77 mS/cm)
    Optional ORPGS5-E separate; not supplied in this base kit
    Temperature measurement range0-50°C (32-122°F)
    Temperature resolution0.1°C / 0.1°F
    TruReadStable for 7 seconds then session collection; average/max/min
    Persistent log / exportNot established by reviewed Gen II instructions
    Reading HOLDManual
    Display colorsWhite measurement; green calibration; red calibration error
    ProtectionIP67; close battery cap/O-ring correctly
    Power4 AAA alkaline batteries; installed
    Idle shutoff10 minutes; see manual for disabling
    Storage routineFor regular use, keep the combo probe in a tightly closed humid cap. For longer storage, follow GS4’s 3M KCl cap-fill instructions, never immersion storage in pure water. Rinse without rubbing the glass. Keep pH-only sample conditioning separate from EC measurements.

    Ordering Information

    Ordering detailIncluded configuration
    Catalog numberAI104G
    Working kitGS4 pen with GS4-E pH/EC combo probe and cap, pH 4.00 and 7.00 buffers (50 mL each), 2.77 EC standard (50 mL), 3M KCl soaking solution (10 mL), four installed AAA batteries, lanyard and instructions.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and ONE YEAR for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    GroStar GS4 documents

    Use the current Gen II guide for controls, sampling and care. The US catalog adds family/probe/kit comparison; it is not a replacement for the operator instructions. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat