Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Biomiga Respiratory Panel Real-Time PCR Detection Kit, 11 Viruses (QP2179), RUO Real-Time PCR Detection Kits Biomiga
Biomiga Respiratory Panel Real-Time PCR Detection Kit, 11 Viruses (QP2179), RUO Real-Time PCR Detection Kits Biomiga
Biomiga Respiratory Panel Real-Time PCR Detection Kit, 11 Viruses (QP2179), RUO Real-Time PCR Detection Kits Biomiga
Biomiga Respiratory Panel Real-Time PCR Detection Kit, 11 Viruses (QP2179), RUO Real-Time PCR Detection Kits Biomiga
Biomiga Respiratory Panel Real-Time PCR Detection Kit, 11 Viruses (QP2179), RUO Real-Time PCR Detection Kits Biomiga
Biomiga Respiratory Panel Real-Time PCR Detection Kit, 11 Viruses (QP2179), RUO Real-Time PCR Detection Kits Biomiga
Biomiga Respiratory Panel Real-Time PCR Detection Kit, 11 Viruses (QP2179), RUO Real-Time PCR Detection Kits Biomiga
Biomiga Respiratory Panel Real-Time PCR Detection Kit, 11 Viruses (QP2179), RUO Real-Time PCR Detection Kits Biomiga
Biomiga Respiratory Panel Real-Time PCR Detection Kit, 11 Viruses (QP2179), RUO Real-Time PCR Detection Kits Biomiga
Biomiga Respiratory Panel Real-Time PCR Detection Kit, 11 Viruses (QP2179), RUO Real-Time PCR Detection Kits Biomiga

Biomiga Respiratory Panel Real-Time PCR Detection Kit, 11 Viruses (QP2179), RUO

$21,500.00

    Multiplex real-time RT-PCR reagent kit that detects 11 respiratory viruses in three reactions per sample, on the open real-time PCR instrument your lab already runs.

    • SARS-CoV-2, influenza A and B, RSV, adenovirus, hMPV, rhinovirus and parainfluenza 1–4
    • Stated analytical sensitivity of 250 copies/mL, with a human RNase P internal control
    • 20 µL reactions read in FAM, JOE/HEX/VIC, ROX and Cy5; ABI 7500 and 7300 plus listed
    • Positive and negative controls included in every kit

    Products are for in vitro research use only (RUO). Not for use in diagnostic procedures.

    Live Inquiry about this product via:

    Email: info@bluetigerscientific.com

    Text/SMS: (833) 928-4437 Mon–Fri, (8 am – 8 pm PST)

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

11 targets
Respiratory viruses per sample
3 wells
Multiplex reactions per sample
250 copies/mL
Stated analytical sensitivity
4 channels
FAM, JOE/HEX/VIC, ROX, Cy5

ONE SAMPLE, ELEVEN VIRUSES

A full respiratory virus menu on the real-time PCR instrument you already own.

The Biomiga Respiratory Panel Real-Time PCR Detection Kit (QP2179) is a multiplex real-time RT-PCR assay for the qualitative detection of eleven respiratory viruses in nucleic acid extracted from oropharyngeal swabs, nasopharyngeal swabs and sputum. Each sample runs in three wells, each read in four fluorescence channels, with a human RNase P internal control and kit positive and negative controls. Because it is an open-platform reagent kit rather than a cartridge system, it runs in standard 96-well batches on common real-time PCR instruments.

For research use only. Not for use in diagnostic procedures.

Target menu

QP2179 viral target and fluorescence-channel assignments across three multiplex mixes, with RNase P control.
PCR MIX I
  • SARS-CoV-2 (RdRp) FAM
  • Influenza A ROX
  • Influenza B Cy5
  • RNase P internal control JOE
PCR MIX II
  • Respiratory syncytial virus JOE
  • Adenovirus FAM
  • Human metapneumovirus ROX
  • Rhinovirus Cy5
PCR MIX III
  • Parainfluenza 4 JOE
  • Parainfluenza 3 FAM
  • Parainfluenza 2 ROX
  • Parainfluenza 1 Cy5

Channel assignments per Biomiga's instructions for use (IFU).

How it works

QP2179 workflow from nucleic acid extraction through three 20 µL PCR reactions and four-channel readout.

Research workflow overview; follow the applicable manufacturer instructions for operating conditions and control interpretation.

STEP 1

Extract

Purify RNA/DNA from the specimen with an extraction kit (not included). The assay is not run on unextracted samples.

STEP 2

Set up

For each mix, combine 14 µL PCR Mix with 1 µL RT-PCR Enzyme Mix, then add 5 µL of extract or control for a 20 µL reaction.

STEP 3

Run

Reverse transcription at 50 °C for 5 min, 95 °C for 2 min, then 40 cycles of 95 °C for 5 s and 60 °C for 20 s.

STEP 4

Read

Confirm the positive and negative controls pass, then read each channel against the IFU's interpretation tables.

INSTRUMENTS

Runs on open real-time PCR platforms

Biomiga lists the Applied Biosystems 7500 Real-Time PCR System and 7300 plus Real-Time PCR System as compatible. The IFU calls for any real-time thermocycler with FAM, JOE (HEX or VIC equivalent), ROX and Cy5 channels.

You supply: nucleic acid extraction reagents, PCR tubes or plates for your cycler, RNase-free 1.5 mL tubes, a vortex mixer, a high-speed centrifuge, micropipettes (0.5–10 µL) with filter tips, and PPE.

What's in the box

Component 100 tests 500 tests
PCR Mix I, II, III 1.5 mL each 5 x 1.5 mL each
RT-PCR Enzyme Mix 330 µL 1,550 µL
Positive Control 1 50 µL 250 µL
Positive Control 2 & 3 50 µL 250 µL
Negative Control 50 µL 250 µL

Specificity

Biomiga reports no cross-reaction with these organisms:

Enterovirus A–DSeasonal coronaviruses HKU1, OC43, NL63, 229ESARS-CoV-1MERS coronavirusEB virusMeaslesMumpsCytomegalovirusVaricella zosterRotavirusNorovirusMycoplasma pneumoniaeChlamydia pneumoniaeLegionellaBordetella pertussisHaemophilus influenzaeStaphylococcus aureusStreptococcus pneumoniaeStreptococcus pyogenesKlebsiella pneumoniaeMycobacterium tuberculosisAspergillus fumigatusCandida albicans and C. glabrataCryptococcus neoformans

Built for respiratory virus research

Surveillance studies

Track co-circulating respiratory viruses across sample sets.

Assay development

A multiplex reference for method comparison and validation work.

Core and high-throughput labs

Batch many samples per plate on an existing cycler.

Teaching and training

Multiplex qPCR with built-in controls and clear readouts.

When this kit is the right call

  • No new analyzer: runs on the open real-time PCR instruments many labs already have.
  • Batch throughput: plate-based, so dozens of samples share one run.
  • Broad menu: SARS-CoV-2, influenza A, influenza B, RSV and seven additional respiratory viruses.
  • Built-in controls: RNase P internal control plus kit positive and negative controls.

Related Biomiga kits

THIS KIT

Respiratory Panel (QP2179)

11 respiratory viruses in 3 reactions.

Pneumonia Panel (QP2168)

13 bacterial targets to pair with the viral panel.

RPP 5-Plex (QP2177)

SARS-CoV-2, Flu A, Flu B, RSV-A and RSV-B in one reaction.

Universal Pathogen DNA/RNA Extraction Kit (VR6568.CX)

Biomiga's co-extraction kit for the extraction step.

Need one of the others? Email info@bluetigerscientific.com or text (833) 928-4437 for a quote.

Frequently asked questions

Quick facts

What it is: A multiplex real-time RT-PCR reagent kit detecting 11 respiratory viruses in three reactions per sample.

Sample types: Nucleic acid extracted from oropharyngeal swabs, nasopharyngeal swabs or sputum.

Instruments: ABI 7500 and 7300 plus, or any cycler with FAM, JOE/HEX/VIC, ROX and Cy5 channels.

Pack sizes: 100 tests and 500 tests.

Use: Research use only. Not for use in diagnostic procedures.

Which viruses does the panel detect?

SARS-CoV-2, influenza A, influenza B, respiratory syncytial virus, adenovirus, human metapneumovirus, rhinovirus, and parainfluenza viruses 1, 2, 3 and 4, plus a human RNase P internal control.

Can this kit be used for patient diagnosis?

No. In the United States it is supplied for research use only and is not for use in diagnostic procedures.

Is an extraction kit included?

No. Nucleic acid must be extracted before testing. Biomiga's Universal Pathogen DNA/RNA Extraction Kit (VR6568.CX) is one option; ask us for a quote.

Will it run on my instrument?

Biomiga lists the Applied Biosystems 7500 and 7300 plus as compatible. Other cyclers need FAM, JOE (HEX/VIC), ROX and Cy5 channels; contact us before ordering if you run a different platform.

How sensitive is the assay?

Biomiga states an analytical sensitivity of 250 copies/mL.

How is the kit shipped and stored?

It ships frozen. Store at -20 ± 5 °C and keep freeze-thaw cycles under five. The expiry date is printed on the label.

What makes a run valid?

The negative control must show no amplification in the Cy5, ROX and FAM channels, and the positive control must amplify in all four channels. If either fails, the run is repeated.

Can my institution get a formal quote?

Yes. Email info@bluetigerscientific.com or text (833) 928-4437 for a formal quote your purchasing department can process. Blue Tiger Scientific is a DVBE-certified supplier.

    SpecificationDetail
    Catalog NumberQP2179-01 (100 tests), QP2179-02 (500 tests)
    MethodMultiplex real-time RT-PCR, fluorescent probes, qualitative
    TargetsSARS-CoV-2, influenza A, influenza B, RSV, adenovirus, human metapneumovirus, rhinovirus, parainfluenza 1, 2, 3 and 4
    Internal ControlHuman RNase P (PCR Mix I)
    Reactions per Sample3 (PCR Mix I, II, III)
    Reaction Volume20 µL (14 µL PCR Mix, 1 µL enzyme mix, 5 µL extract)
    Detection ChannelsFAM, JOE (HEX/VIC), ROX, Cy5
    Cycling50 °C 5 min; 95 °C 2 min; 40 x (95 °C 5 s, 60 °C 20 s)
    Analytical Sensitivity250 copies/mL (as stated by Biomiga)
    Sample TypesExtracted nucleic acid from oropharyngeal swabs, nasopharyngeal swabs, sputum
    Listed InstrumentsApplied Biosystems 7500; 7300 plus
    Shipping and StorageShips frozen. Store at -20 ± 5 °C; fewer than 5 freeze-thaw cycles
    ExpiryPrinted on the kit label
    Country of OriginUSA
    Intended UseResearch use only (RUO). Not for use in diagnostic procedures

    Terms & Conditions

    Blue Tiger Scientific is an independent distributor of products manufactured by Biomiga, Inc. By purchasing from bluetigerscientific.com, you (“the Customer”) agree to the following terms.

    Product Use & Eligibility
    Products are for in vitro research use only (RUO). They are not intended for human or animal use, diagnostic procedures, or therapy, and may not be resold to consumers. Sales are limited to verified institutional and business customers shipping to a business address; we do not ship to residential addresses. Blue Tiger Scientific may request institutional verification or end-use information before shipping and may cancel any order that cannot be verified.

    Payment Terms
    Orders are prepaid by card, or invoiced against an institutional purchase order once credit is approved. Prices are in USD and subject to change without notice. Purchase orders are due within 30 days of invoice unless agreed otherwise in writing.

    Order Confirmation & Cancellations
    Confirmed orders are placed with the manufacturer and are final. Changes or cancellations must be requested in writing before shipment and approved by Blue Tiger Scientific; approved cancellations may incur restocking, materials or third-party fees.

    Accuracy of Orders
    Customers are responsible for verifying catalog numbers, pack sizes, ship-to address and recipient availability before submitting an order.

    Shipping & Cold Chain
    Shipping is calculated at checkout. Temperature-sensitive products ship by expedited service, and ship dates may be adjusted to avoid weekend or holiday transit. Orders placed on weekends or holidays are processed the next business day. Delivery dates are estimates and are not guaranteed. A recipient must be available to receive and store temperature-sensitive products on arrival. Blue Tiger Scientific is not liable for carrier delays, weather disruptions or other events beyond our control.

    Receiving & Claims
    Inspect every shipment on arrival. Shortages, damage or thawed temperature-sensitive product must be reported to Blue Tiger Scientific in writing, with photos, within 2 business days of delivery. Claims received after that window, and shipments that are refused, unclaimed or left unattended, are not eligible for credit or replacement.

    Returns & Refunds
    Returns require a Return Merchandise Authorization (RMA) issued by Blue Tiger Scientific and must be requested within 30 days of delivery. Refunds or replacements are issued only for shipping errors or verified product defects. Temperature-sensitive products are not returnable once delivered. Customers pay return shipping unless the error was ours, and refunds exclude original shipping charges. Approved refunds are processed within 45 business days.

    Warranty
    Biomiga warrants its products to perform as described in their labeling when used in accordance with their instructions; the remedy for a product that does not is replacement, at Biomiga's option. Blue Tiger Scientific coordinates these claims with Biomiga. No other warranties, express or implied, are given.

    Limitation of Liability
    Blue Tiger Scientific's total liability for any claim is limited to the purchase price of the product involved. Blue Tiger Scientific and Biomiga are not liable for indirect, incidental or consequential damages, including lost research time or materials, arising from the use or misuse of any product.

    Safety
    Handle all products according to the Safety Data Sheet and the manufacturer's instructions, using appropriate personal protective equipment.

    Legal & Export Compliance
    Customers must use products in compliance with all applicable local, state, federal and international laws, including export control and biosafety regulations. Products may not be exported or re-exported without the required authorizations.

    Resale
    Products may not be resold or redistributed without prior written approval from Blue Tiger Scientific.

    Force Majeure
    Neither party is liable for delays or failures caused by events beyond its reasonable control, including weather, carrier disruptions, supply shortages or changes in regulation.

    Governing Law
    These terms are governed by the laws of the State of California and the United States.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat