Portable general-water pH, a replaceable temperature-sensing electrode and a deliberate USB recordkeeping workflow.
Preparing Quote Cart. Your shopping cart stays unchanged.
APERA INSTRUMENTS / PH8500 / AI5520
Build a portable routine for general-water pH testing with the PH8500, its supplied 201T-F pH/temperature electrode and USB data workflow. The backlit display brings the selected reading, temperature and measurement indicators together, while the fold-out stand lets the same instrument work beside a sample vessel at the bench. A carrying case keeps the core testing kit together between locations.
Choose AI5520 when pH is the primary measurement and the samples suit a general-water electrode. Choose PC8500 for pH plus conductivity, or EC8500 for conductivity-focused work. Within the pH family, PH8500-PW uses LabSen 803 for low-ionic water, PH8500-WW uses LabSen 333 for wastewater and suspensions, and PH8500-MS uses LabSen 243-6 for small samples. These are different electrode configurations, not extra probes in this box.
Each card opens that model page. Match the supplied electrode and documented sample method. Different configurations are not interchangeable upgrades, and optional accessories are not supplied unless the exact kit contents say so.
AI5520
General portable pH
201T-F general-water pH/temperature electrode.
AI5522
Conductivity and derived values
2301T-S K=1 conductivity/temperature electrode.
AI5524
Separate pH and EC workflows
201T-F and 2301T-S, two distinct electrodes.
AI5556
Low ionic strength water
LabSen 803 refillable sleeve-junction electrode.
AI5559
Suspensions and wastewater
LabSen 333 open-junction polymer-reference electrode.
AI5554
Small-volume samples
LabSen 243-6 plus included semi-micro container.
Harsh-chemistry kits
AI5525
Strong acid & HF
LabSen 833: HF-type glass, ceramic junction.
AI5523
Strong alkali & high salinity
LabSen 843: HA (high-alkali) glass, ceramic junction.
AI5566
Hot, complex & caustic liquids
LabSen 863: PHY glass, PTFE ring junction.
The 201T-F combines the pH glass membrane, reference system and temperature sensor in one probe. Its blue BNC connection carries pH/mV and its black RCA connection carries temperature. The sealed gel KCl reference is nonrefillable, so routine care is external rinsing, cleaning and wet storage, not opening the probe to replenish electrolyte. The supplied probe supports automatic temperature compensation without a separate temperature probe.
The meter provides ±0.01 pH ±1 digit accuracy, selectable 0.1 or 0.01 pH resolution and a stability indicator to guide when a result is ready to record. Calibration review includes the latest offset, slope and date/time. Selectable stability criteria and optional automatic hold support a repeatable reading routine. IP57 housing and the fold-out stand suit movement between work areas; keep connectors clean, dry and appropriately protected.
Away from the computer, manual M+ saving and timed logging use the meter’s 500-set memory. USB PC-Link provides a computer workflow through desktop Chrome or Edge on Windows or Mac, with CSV export and browser printing. Crucially, new readings logged while connected go to PC-Link software instead of meter memory. Export and check the files before ending a session; a connected session is not a duplicate meter backup.
Use this base configuration for compatible aqueous samples where a conventional general-water pH electrode fits the method. Collect a representative sample, allow temperature to settle and use a consistent immersion and stabilization routine. The meter’s wider electronic range does not turn the supplied probe into a high-temperature or strongly caustic sensor.
Take the same instrument and calibration routine between sample locations and the laboratory. The portable format is useful when a fixed benchtop station would interrupt the work. Record sample identity separately alongside the exported results, and check the meter clock before logging so date and time remain meaningful to your own records.
Very low-ionic water, fouling wastewater and tiny sample volumes call for different electrode decisions. The PW, WW and MS configurations address those distinct tasks; they do not simply add meter accuracy. For MS, the published 60 µL minimum depends on the included 6 mm semi-micro container. Do not apply that volume to this full-size 201T-F.
Connect both electrode plugs, remove the storage bottle and rinse the sensing end with distilled or deionized water. Shake away excess rinse water without rubbing the glass membrane. Set the intended buffer series and check the date, time and logging settings before starting a run. When fitting a new 201T-F, follow its instruction to perform a three-point calibration before relying on measurements.
Begin pH calibration with the neutral buffer for the selected series: pH 7.00 for USA or 6.86 for NIST. Use fresh portions and additional points appropriate to the expected samples. The kit supplies 50 mL each of pH 4.00, 7.00 and 10.01 buffer. Rinse between standards and samples, gently stir to release bubbles, and wait for the stability indicator before saving. Temperature compensation corrects electrode response, not every temperature-driven change in sample chemistry.
Decide whether the run belongs in meter memory or in a connected PC-Link session before collecting results. Timed logging uses a configured interval; manual saving suits selected stable readings. Review the latest calibration information with the data, export the CSV for spreadsheet work and use browser print when a report is needed. Verify the saved output before clearing memory or closing the browser. Keep your sample notes and file backups under your laboratory’s own procedure.
Use the narrower supplied-probe limits of 0 to 13 pH and 0 to 60 °C when selecting samples, rather than the meter’s -2 to 16 pH range. The electrode instructions also caution against prolonged testing above 50 °C, frequent strongly acidic or alkaline testing, low-ionic water and chemicals that attack the polycarbonate housing. If that describes the routine, select a more suitable electrode configuration before buying.
After measurement, rinse away residue and return the glass sensing end to its KCl-filled storage bottle. Use the specified electrode storage solution, AI1107, and replace it when contaminated. Distilled or deionized water is suitable for rinsing but not pH-electrode storage. The internal gel reference does not need refilling. Do not confuse adding solution to the external storage bottle with replenishing an internal reference chamber.
Keep the glass membrane free of deposits and protect it from impact. Follow electrode-specific cleaning instructions for the contaminant, rinse thoroughly and recalibrate after cleaning or conditioning. A slower response or declining slope calls for investigation rather than simply waiting longer. The current limited manufacturer warranty is three years for the instrument and six months for the probe from delivery, subject to terms and exclusions; it is not a promise of electrode service life.
Use the physical controls for standalone measurement and calibration. The stable-reading indicator and HOLD help you read a result; a held display is not an onboard measurement-history logger for later upload.
Keep the connectors and battery compartment dry when changing parts. Follow the exact manual for key sequences, battery orientation and cap sealing. Screen values in photographs are illustrative, not test results or a promise of compatibility with another sensing head.
Each 8500 meter can measure and calibrate without a computer. It can retain up to 500 data sets, including date, time, measured value, unit, temperature and the last calibration record. M+ supports manual saving after stability; timed logging can be set from one minute through 99 hours 59 minutes. Deleting stored values cannot be undone.
For computer work, use the meter USB connection with the current Web PC-Link workflow on a desktop Chrome or Edge browser under Windows or Mac. The tool supports CSV output and browser-print reporting. Do not assume Firefox compatibility, a native Excel/PDF export format, an immutable audit trail, electronic signatures or regulatory validation.
When connected to PC-Link, new records go to the software rather than to the meter memory. Save and export important records before closing the browser. USB logging does not guarantee automatic backup, permanent retention or protection from user deletion. Keep the exact meter, configured probe and sample method with any record.
Alternative format: Apera PH20 Waterproof Pocket pH Tester Kit (AI209). Compare the exact standalone kit when Bluetooth-connected recordkeeping is not needed. A related family name does not establish the same probe upgrades or app support.
No. This base kit is for pH and temperature. Choose PC8500 if you also need conductivity and its derived modes, or EC8500 if conductivity is the primary task.
The kit includes 201T-F, replacement SKU AI1302, with BNC pH and RCA temperature connections. Its internal gel KCl reference is nonrefillable. Keep the sensing tip wet in the specified external KCl storage solution.
Do not select the base 201T-F for low-ionic pure water or assume universal chemical resistance. Its conservative working limits are 0 to 13 pH and 0 to 60 °C, with additional cautions for prolonged heat and frequent extreme pH. PH8500-PW is the family’s low-ionic-water configuration.
The meter holds 500 data sets total, using manual or timed logging. When connected to PC-Link, newly logged readings go to the software instead of meter memory. Export and verify the computer files before ending the session.
Yes. The documented web workflow supports desktop Chrome or Edge on Windows and Mac. USB PC-Link offers CSV export and browser print. This is a computer USB workflow, not a phone-app or wireless connection.
Three bottles: pH 4.00, 7.00 and 10.01, 50 mL each. These are calibration solutions, not long-term electrode storage solutions. No separate calibration-vial count is promised.
No. An optional 301Pt-C ORP electrode is required for ORP work and is sold separately. A millivolt reading from the supplied pH electrode is not an ORP result.
Current limited manufacturer coverage is three years for the instrument and six months for the probe from delivery, subject to exclusions. The meter requires three AA batteries. Battery inclusion and a supplied power adapter are not confirmed, so neither is promised as a kit item.
Review PH8500 AI5520 and return to the price and ordering controls. Blue Tiger Scientific can help clarify the sample, electrode and documentation requirements.
Apera Manufacturer Limited Warranty
Apera states a limited three-year warranty for the instrument and a six-month warranty for the supplied probe from delivery, for defects attributable to the manufacturer and subject to its stated conditions.
Normal wear, accidental damage, improper use, transport or storage damage, failure to follow instructions, unauthorized repairs or modifications and other external causes are excluded. Keep the exact product and purchase details when requesting service.
Use exact-kit instructions and the qualifications on this page. Supplemental electrode tables may have revision differences; document titles explain their scope. Each card opens a PDF in a new tab.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.