Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PH60S Spear pH Tester Kit (AI313) Pocket Food-Grade pH Tester Apera Instruments
Apera PH60S Spear pH Tester Kit (AI313) Pocket Food-Grade pH Tester Apera Instruments
Apera PH60S Spear pH Tester Kit (AI313) Pocket Food-Grade pH Tester Apera Instruments
Apera PH60S Spear pH Tester Kit (AI313) Pocket Food-Grade pH Tester Apera Instruments
Apera PH60S Spear pH Tester Kit (AI313) Pocket Food-Grade pH Tester Apera Instruments
Apera PH60S Spear pH Tester Kit (AI313) Pocket Food-Grade pH Tester Apera Instruments
Apera PH60S Spear pH Tester Kit (AI313) Pocket Food-Grade pH Tester Apera Instruments
Apera PH60S Spear pH Tester Kit (AI313) Pocket Food-Grade pH Tester Apera Instruments
Apera PH60S Spear pH Tester Kit (AI313) Pocket Food-Grade pH Tester Apera Instruments
Apera PH60S Spear pH Tester Kit (AI313) Pocket Food-Grade pH Tester Apera Instruments

Apera PH60S Spear pH Tester Kit (AI313)

$253.00

    Measure the sample. Not just the liquid around it. The PH60S brings a replaceable spear-shaped pH electrode to water-containing soft solids, semi-solids and viscous samples. Test suitable cheese, meat, fruit, dough or sauces with a kit built around the sample-contact task.

    • PH60S-E / AI1205 replaceable electrode
    • 0.01 pH resolution; ±0.01 pH ±1 digit accuracy
    • Includes pH 4/7/10.01 buffers, KCl storage solution, batteries and case

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PH60S / AI313

Measure the sample.
Not just the liquid around it.

The PH60S brings a replaceable spear-shaped pH electrode to water-containing soft solids, semi-solids and viscous samples. Test suitable cheese, meat, fruit, dough or sauces with a kit built around the sample-contact task.

Choose AI313 when a standard bulb is awkward for the sample. Match its spear contact, temperature range and sample-preparation method to your application before testing.

Apera PH60S tester with its standard sensor
Apera PH60S · AI313 standard kit

Spear glass

Direct sample contact

PH60S-E replaceable electrode

0.01 pH

Resolution

Accuracy: ±0.01 pH ±1 digit

IP67

Waterproof body

Portable case and calibration supplies

Open the case. Know what is included.

The AI313 kit includes the PH60S tester and its PH60S-E / AI1205 electrode, pH 4.00, 7.00 and 10.01 buffers, 3M KCl storage solution, three calibration vials, four AAA batteries, lanyard, carrying case and instructions.

Apera PH60S standard kit and supplied accessories
The standard AI313 kit. Other 60-series electrodes are separate purchases, not extra tips included in this kit.

Model-specific pH electrode

PH60S-E / AI1205 supplied with the tester

Three calibration buffers

pH 4.00, 7.00 and 10.01 with calibration vials

Probe care and power

3M KCl storage solution and four AAA batteries

Ready to carry

Lanyard, protective case and instructions

MATCH THE INSTRUMENT TO THE SAMPLE

Where PH60S earns its place.

Soft foods and semi-solids

Use suitable samples containing water, such as cheese, fruit, meat or dough. Prepare hard samples with a pilot hole instead of forcing the glass spear.

Sauces, yogurt and viscous mixtures

Bring the sensing tip into direct contact with a suitable water-containing sample. Clean residues between samples so carryover does not compromise the next reading.

Product development and sample checks

Compare prepared samples within a defined method. A pH result alone does not establish microbiological safety, shelf life or suitability for consumption.

The current PH60S manual discourages soil and high-particulate samples because particles can block the reference junction. Test a separate sample portion; the manual instructs that tested food should not be eaten. Never force the glass spear into hard or frozen material.

A spear tip for samples a bulb does not suit.

PH60S combines fine display resolution, automatic 1-3 point calibration and a backlit pH/temperature display. The replaceable spear electrode gives you a defined maintenance path, while the stability indicator helps identify when to record the reading.

The PH60S-E spear electrode uses a polymer-gel reference system and is replaceable. Keep it hydrated in 3M KCl, handle the glass gently and clean off sample residues before the next test. Do not let the spear dry out.

Apera PH60S spear glass sensor detail
Sensor geometry and maintenance requirements are model-specific.

A clear routine, from setup to storage.

01

Calibrate with clean standards

Start with pH 7.00, then use pH 4.00 and/or 10.01 as appropriate to the expected sample. Wait for a stable reading before confirming.

02

Prepare and measure a sample portion

Use a suitable water-containing sample, make a pilot hole if needed and avoid excessive force. Keep temperatures within the instrument limits and wait for stability before recording.

03

Clean and keep the spear hydrated

Rinse away residues, follow the manual’s cleaning guidance and keep the PH60S-E stored in 3M KCl. Do not let it dry or store it in pure water.

PH60S Food pH Tester with Swiss Spear Glass Probe · Apera Instruments

Which electrode shape do I need?

These are different measurement choices, not interchangeable names for the same application.

Bulb · PH60

For regular aqueous samples where a glass bulb is the appropriate contact geometry.

Flat · PH60F

For suitable surface-contact and small-volume methods, with the flat sensing face correctly wetted.

Spear · PH60S

For water-containing soft solids, semi-solids and viscous samples. Not a general soil pen.

See PH60S in use.

Watch the manufacturer’s sample-measurement demonstration alongside the written steps. Keep the current manual as the authority for preparation, calibration and care.

Optional electrode illustrations do not mean extra tips are included. The standard AI313 kit is described above; choose additional accessories only for a verified requirement.

Complete the measurement workflow.

Keep pH, conductivity, TDS and salinity distinct when choosing instruments. The following are related measurement options, not accessories that attach to this tester.

Related workflow: Apera EC60 conductivity/TDS/salinity tester

Alternative format: Apera PC60 multi-parameter water-quality tester

PH60S buyer questions

What comes in the PH60S AI313 kit?

The kit includes PH60S with PH60S-E spear electrode, pH 4.00, 7.00 and 10.01 buffers, 3M KCl storage solution, three calibration vials, four AAA batteries, lanyard, carrying case and instructions.

Which samples suit the PH60S spear electrode?

Apera lists water-containing soft solids, semi-solids and viscous samples such as cheese, meat, fruit, sushi rice, dough, yogurt and sauces. Choose a sample preparation and cleaning routine appropriate to the material.

Can PH60S measure soil pH?

Do not select it as a general soil pen. The current PH60S manual discourages soil and samples with many solid particles because they can block the reference junction. Use a soil-specific method and instrument instead.

Can I insert PH60S into hard or frozen food?

Do not force the glass spear into hard or frozen material. Prepare the sample as required and make a pilot hole for hard samples. Use a suitable temperature and handle the glass tip carefully.

Does measuring pH prove a food is safe?

No. A pH reading alone does not establish food safety or shelf life. Test a separate sample portion and follow the current manual, which instructs that tested food should not be eaten.

What are PH60S accuracy and temperature limits?

Specified pH accuracy is ±0.01 pH ±1 digit, with 0.01 pH resolution. The rated temperature/ATC interval is 0 to 50°C; the current manual advises avoiding below 5°C or above 45°C for best accuracy and probe care.

Is the PH60S probe replaceable?

Yes. Its standard replacement electrode is PH60S-E, catalog AI1205. The pH probe is a separate replacement item; do not assume every tip pictured in a series illustration is supplied in AI313.

How do I clean and store the spear probe?

Rinse off residues between samples, use the manual’s cleaning and reconditioning method for contamination, and keep the spear hydrated in 3M KCl solution. Do not let it dry and never use pure water for storage.

Choose the kit that fits the work.

Review the PH60S specifications, included items and sample requirements, then return to the price and ordering controls. Blue Tiger Scientific can help you compare the measurement options before ordering.

Back to price and ordering ↑
    SpecificationDetail
    BrandApera Instruments
    Model / catalog numberPH60S / AI313
    Standard electrodePH60S-E / AI1205
    Electrode geometrySpear glass
    Electrode replacementReplaceable
    Meter pH range-2.00 to 16.00 pH
    Supplied-electrode pH range0 to 14 pH
    pH resolution0.01 pH
    pH accuracy±0.01 pH ±1 digit
    CalibrationAutomatic 1-3 points
    Included pH buffers4.00, 7.00 and 10.01
    Temperature measurement0 to 50°C (32 to 122°F)
    Automatic temperature compensation0 to 50°C (32 to 122°F)
    Temperature resolution0.1°C
    Temperature accuracy±0.5°C
    DisplayThree-color backlit LCD; pH and temperature
    Reading functionsStability indication; automatic HOLD when enabled
    ProtectionIP67
    Power4 AAA batteries; included
    ORP capabilityRequires separately sold ORP60-E / AI1207; not included
    Included storage solution3M KCl

    Ordering Information

    Ordering detailIncluded configuration
    Catalog numberAI313
    ConfigurationThe AI313 kit includes the PH60S tester and its PH60S-E / AI1205 electrode, pH 4.00, 7.00 and 10.01 buffers, 3M KCl storage solution, three calibration vials, four AAA batteries, lanyard, carrying case and instructions.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants  this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    Apera PH60S documents

    Open the official English instructions and product brochure. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat