Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera PH60-MT Meat pH Kit with LabSen 765 Blade Probe pH Meter Apera Instruments
Apera PH60-MT Meat pH Kit with LabSen 765 Blade Probe pH Meter Apera Instruments
Apera PH60-MT Meat pH Kit with LabSen 765 Blade Probe pH Meter Apera Instruments
Apera PH60-MT Meat pH Kit with LabSen 765 Blade Probe pH Meter Apera Instruments
Apera PH60-MT Meat pH Kit with LabSen 765 Blade Probe pH Meter Apera Instruments
Apera PH60-MT Meat pH Kit with LabSen 765 Blade Probe pH Meter Apera Instruments
Apera PH60-MT Meat pH Kit with LabSen 765 Blade Probe pH Meter Apera Instruments
Apera PH60-MT Meat pH Kit with LabSen 765 Blade Probe pH Meter Apera Instruments
Apera PH60-MT Meat pH Kit with LabSen 765 Blade Probe pH Meter Apera Instruments
Apera PH60-MT Meat pH Kit with LabSen 765 Blade Probe pH Meter Apera Instruments

Apera PH60-MT Meat pH Kit with LabSen 765 Blade Probe

$339.00

    A protected spear. A deliberate sampling method. The PH60-MT pairs PH60 with LabSen 765 for its defined sample workflow.

    • Exact external probe: LabSen 765 / AI3245
    • Includes pH 4.00, 7.00 and 10.01 buffers, CalPod and KCl storage solution
    • Meter limits and electrode/sample limits are separate

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA INSTRUMENTS / PH60-MT / AI3735

A protected spear.
A deliberate sampling method.

PH60-MT combines the portable meter with the LabSen 765 blade-spear assembly for suitable meat and other solid-food samples. The titanium blade sheath helps prepare contact around a glass sensing element; it does not make the tip unbreakable.

Choose AI3735 for a defined food-pH sampling method. Hard/frozen-material preparation is distinct from validated subzero analysis, and a pH reading alone does not establish food safety or freshness.

Apera PH60-MT with specified LabSen 765 external electrode
Matched kit: PH60 body and LabSen 765. The external electrode is not an extra generic PH60-E.

LabSen 765

Supplied electrode

Replacement AI3245

0.01 pH

Meter resolution

Meter accuracy: ±0.01 pH ±1 digit

8-pin

Matched external connection

Not an ordinary BNC-only substitution

Find the PH60 kit for your sampleClick or tap to compare all 8 kitsChoose a model below - click or tap here to close

SAMPLE PREPARATION AND ANALYTICAL TEMPERATURE ARE DISTINCT

Prepare the pathway.
Protect the glass.

Suitable soft sample

Use the manual’s direct-contact method with the sensing membrane and junction in contact.

Hard/frozen material

The manufacturer describes a blade-created pathway before inserting the electrode; do not force the glass tip through a hard block.

Temperature and method

Frozen-material marketing does not establish validated subzero measurement or a universal thaw protocol.

The titanium blade sheath protects a glass sensing assembly. It does not turn it into an unbreakable metal spike, and a pH number is not a food-safety or freshness verdict.

Exact PH60-MT kit diagram from its currentUS manufacturer manual
Manufacturer kit diagram. The text checklist provides readable ordering details; solution volumes are not assumed from other regions.

Know the exact probe
and standards in the case.

PH60 meter body, LabSen 765 external pH/temperature electrode, CalPod solution organizer, pH 4.00, 7.00 and 10.01 buffers, 3M KCl storage solution, protective cap, instructions and carrying case. Four AAA batteries are factory-installed per the model’s preparation instructions.

The current US kit buffer set is pH 4.00, 7.00 and 10.01. Match that working set to your sample and calibration method; do not assume every specialized PH60 package contains the same buffers.

SAMPLE FIT BEFORE FEATURE COUNT

Where this configuration fits.

Suitable prepared meat samples

Use a representative sample and the specified probe contact. The glass membrane and reference junction still need the correct sample pathway.

Hard or frozen material

The manufacturer describes blade-created preparation before electrode insertion. Do not interpret frozen-meat marketing as permission to force glass through a hard block or as a subzero accuracy claim.

Other appropriate solid foods

Match food structure and preparation to an established method. No universal direct-insertion protocol or pathogen/shelf-life assurance follows from a product category.

The electrode is the specialized part.

Titanium blade sheath protecting a glass pH sensing electrode. The open plus ceramic junction (per current US kit manual) and its sample contact are part of the method, not a universal chemical-compatibility or maintenance-free guarantee.

The sensing assembly still contains glass. A protective titanium sheath is not an all-metal/unbreakable sensor, and frozen-material marketing does not establish validated measurements below 0 °C.

Manufacturer PH60-MT sample/probe reference illustration
Reference imagery illustrates the application or technology. The supplied exact probe is LabSen 765.

Set up the method before chasing the number.

For suitably prepared soft meat, the manual describes direct sample contact. Hard/frozen material needs the blade-created pathway before the electrode is inserted. Follow the actual method and temperature conditions rather than assuming all foods are tested identically.

Calibrate the pH system

Use the specified kit buffers and current instructions. Start at neutral as directed, then choose the appropriate additional points. Do not infer an included ORP or EC probe.

Make the right contact

Keep glass and junction in contact with a representative sample, limit carryover, and wait for a stable reading under the defined method.

Meter electronics and sample suitability are different.

The current US specialized-kit manual specifies a PH60 display range of -2.00 to 16.00 pH, 0.01 pH resolution and ±0.01 pH ±1 digit meter accuracy. Those numbers do not by themselves establish probe-range, chemical compatibility or total method accuracy.

Temperature measurement/ATC is 0-100 °C in these current US kit instructions. A higher electrode-only temperature figure does not extend that electronic interval or validate every part of the assembly in the sample.

This probe’s temperature context

Current US kit manual electrode rating 0-80 °C; no validated subzero analytical claim

Storage solution is not a refill instruction.

The listed LabSen 765 is non-refillable. Its internal reference/electrolyte description is separate from the external 3M KCl storage vial. Do not open/refill the reference because a chemical name appears in a table.

Rinse before and after measurements without rubbing the glass. Use contaminant-specific manufacturer care rather than an improvised chemical recipe; after deep cleaning follow the required rehydration and recalibration sequence.

Store the probe in its tightly closed vial with the specified 3M KCl solution, not tap, RO, distilled or deionized water. Keep solution fresh and the connector clean/dry. A dry or poorly stored probe needs the model’s recovery routine before calibration.

See the LabSen family technology.

Apera’s electrode-family introduction explains the general technology. It is not an exact PH60-MT operating tutorial; use this kit’s current manual for sample preparation, limits and care.

Related general-water measurement workflows.

These are separate instruments for different water-measurement tasks, not substitute specialized electrodes for PH60-MT. A general-water meter link does not establish HF, caustic, hot-process or direct-food compatibility.

Related workflow: Hanna HI98195 general-water pH/ORP/EC meter

Related workflow: Hanna HI98197 pure-water EC/resistivity meter

PH60-MT buying and method questions

What probe is supplied in PH60-MT?

The exact kit and BOM specify LabSen 765, AI3245. A manual introduction naming 865 is a source typo, not a reason to substitute the high-temperature 865 electrode.

What is included in AI3735?

PH60, LabSen 765, CalPod, pH 4.00/7.00/10.01 buffers, 3M KCl storage solution, cap, instructions and case are listed, with installed four AAA batteries indicated by preparation.

Can I force it directly into frozen meat?

No. The manual describes a blade-created pathway for hard/frozen material before electrode insertion. The sensing element still includes glass and should not be used as a drilling stake.

Does frozen-meat marketing establish subzero performance?

No. The reviewed manual starts its electrode-temperature rating at 0 °C and does not establish a validated subzero method. Confirm sample preparation and actual conditions with the method; no blanket thaw-first rule is invented here.

Does a pH result tell me the meat is safe?

No. pH alone does not prove pathogen absence, freshness, safe processing or fitness to eat. Use the required food-safety procedures and analytical methods.

Is the blade assembly glass-free or refillable?

No. The titanium sheath protects a glass sensing assembly, and the 765 is specified as non-refillable. Neither description establishes an unbreakable or refillable design.

What temperature range should I use?

The current US kit manual lists the 765 electrode at 0-80 °C; other web tables differ. The meter’s 0-100 °C temperature/ATC capability does not override the electrode or method limits.

How do I store and replace it?

Use the specified 3M KCl storage-vial routine and current cleaning/rehydration guidance, not pure water storage or abrasion. The exact replacement is LabSen 765, AI3245, with matching 8-pin connection.

Match the sample.
Confirm the exact kit.

Review PH60-MT and its LabSen 765 configuration, then return to the price and ordering controls. Blue Tiger Scientific can help clarify exact kit, probe and method requirements before ordering.

Back to price and ordering ↑
    SpecificationDetail
    BrandApera Instruments
    Kit / manufacturer catalogPH60-MT / AI3735
    Included electrodeLabSen 765 / AI3245
    Electrode interface8-pin; matched PH60 socket arrangement
    RefillableNo; storage liquid is external
    JunctionOpen plus ceramic, per current US kit manual
    Specialized reference/sensorTitanium blade sheath protecting a glass pH sensing electrode
    Meter pH range-2.00 to 16.00 pH
    Meter pH resolution0.01 pH
    Meter pH accuracy±0.01 pH ±1 digit
    Temperature measurement / ATC0-100 °C in current US kit manual; not an unrestricted probe/system rating
    Temperature resolution0.1 °C
    Probe temperature contextCurrent US kit manual electrode rating 0-80 °C; no validated subzero analytical claim
    Supplied US pH bufferspH 4.00, 7.00 and 10.01
    External storage solution3M KCl; not a refill instruction
    Power4 AAA alkaline batteries; installed per preparation guide
    ReadoutpH and temperature
    Optional ORPORP electrode not supplied or implied by this kit
    Sample-method noteThe sensing assembly still contains glass. A protective titanium sheath is not an all-metal/unbreakable sensor, and frozen-material marketing does not establish validated measurements below 0 °C.
    Preparation distinctionBlade-created pathway for hard/frozen material does not establish subzero analysis

    Ordering Information

    Ordering detailIncluded configuration
    Manufacturer catalogAI3735
    Blue Tiger SKUBTS-AI3735
    Working kitPH60 meter body, LabSen 765 external pH/temperature electrode, CalPod solution organizer, pH 4.00, 7.00 and 10.01 buffers, 3M KCl storage solution, protective cap, instructions and carrying case. Four AAA batteries are factory-installed per the model’s preparation instructions.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants  this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and SIX MONTHS for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    PH60-MT official documents

    Use the current US exact-kit manual for the supplied configuration and operation. The LabSen handbook is additional method/selection reference, not a replacement for those instructions. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat