Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments
Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G) Pocket Multi-Parameter Meter Apera Instruments

Apera GroStar GS4-P Gen II pH/EC/ORP Kit (AI204G)

$245.00

    The combo pen with the ORP head supplied, not merely compatible. GroStar GS4-P Gen II combines its model-specific sensor setup with a practical calibration routine and TruRead session summaries.

    • Liquid pH, EC and calculated 500/700 ppm scales
    • GS4-E / AI804G plus GS5-E / AI805G replaceable configuration
    • pH 4/7, 2.77 EC, KCl and four AAA batteries supplied

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA GROSTAR / GS4-P / GEN II / AI204G

Your pH and EC routine.
Plus a separate ORP probe.

GS4-P supplies the GS4 pH/EC combo pen and an additional GS5-E platinum ORP probe. That makes the extra sensor a visible kit item, not an assumed mode of the installed combo head.

Choose the P kit when pH, EC/ppm and separate ORP checks belong in your liquid-testing workflow. Exchange the head for ORP; it is not simultaneous pH/EC/ORP measurement from one sensor.

Apera GroStar GS4-P manufacturer product photograph
Current manufacturer GS4-P photograph shows the separate ORP head.

2 probes

One pen body

Combo setup or ORP setup after a swap

pH + EC/ppm

Standard combo head

500 and 700 are calculated scales

GS5-E

ORP head included

A separate platinum sensing probe

Find your GroStar modelClick or tap to compare all 6 modelsChoose a model below - click or tap here to close

ONE SOLUTION. DIFFERENT CONVERSION SCALES.

1300 ppm or 1820 ppm?
Both can be the same solution.

Start with the conductivity. Apera’s worked example uses 2.6 mS/cm. The 500 and 700 displays apply different multipliers to that same EC; changing the scale does not change the nutrient solution.

2.6 mS/cm

The measured EC

1300 ppm

500 scale: 2.6 × 500

1820 ppm

700 scale: 2.6 × 700

Match the feed chart’s scale, or compare EC directly. This is a conversion example, not a recommended feed strength or dosing target.

GroStar GS4-P body with standard head and separate GS5-E ORP probe
Manufacturer illustration of the physical two-head configuration; the included ORP probe is separate.

One body. Two heads.
Two separate measurement setups.

The P kit supplies both the standard probe and GS5-E. Physically change the installed head to move between the standard setup and ORP. The extra probe is not hidden inside the pH or combo head.

Standard setup

pH, EC, calculated ppm and temperature with GS4-E.

Swap to ORP

Fit the supplied GS5-E and confirm mV mode. ORP is a separate measurement step, not simultaneous capture with the other probe.

What arrives with AI204G?

GS4 pen with GS4-E combo probe and cap, separate GS5-E ORP probe, pH 4.00 and 7.00 buffers (50 mL each), 2.77 EC standard (50 mL), 3M KCl soaking solution (10 mL), four installed AAA batteries, lanyard and instructions.

The supplied-fluid list is separate from optional compatibility: ORP checking solution and pH 10.01 are separate.

Manufacturer GS4-P kit or supplied-probe reference
Manufacturer contents reference. Outer packaging can vary; the text checklist identifies the supplied working items.

WHAT THIS MODEL IS BUILT TO ANSWER

Where GS4-P belongs in the routine.

Daily nutrient-solution checks

Use the GS4-E for pH and conductivity-based feed measurements. Keep the pH calibration and EC calibration distinct.

A separate ORP step

Fit GS5-E to take redox readings as part of an established procedure. An ORP result is not a direct disinfectant concentration or safety verdict.

A complete two-head purchase decision

Compare base GS4 with GS4-P by what is physically supplied. Optional compatibility is not the same as an included accessory.

Choose the contact, not just the model number.

Supplied probe: GS4-E / AI804G plus GS5-E / AI805G. The standard head combines double-junction glass pH and titanium EC sensing; the two ppm scales are calculated from EC.

Replaceability gives the worn sensor a maintenance path; it is not an unlimited service-life guarantee. Install, condition and calibrate the correct head according to its instructions.

GroStar GS4-P supplied sensing probe detail
Sensing surfaces and care instructions are probe-specific.

A SESSION SUMMARY, NOT A CLOUD LOGGER

Read several spots.
See the spread, not just one number.

In the documented Gen II TruRead workflow, a reading that has stayed stable for seven seconds is recorded for the session. Review the average, maximum and minimum after collecting your measurements. Seven seconds of stability is not the same as a fixed seven-second sampling interval.

6.2 pH

Illustrative minimum

6.3 pH

Illustrative average

6.4 pH

Illustrative maximum

The three illustrative values explain the summary; they do not prescribe a fixed sample count. This pH example does not establish TruRead behavior for the separate ORP setup. The reviewed instructions do not establish retained history, timestamps or export. Use a suitable logger if those are requirements.

Calibrate the sensor you are actually using.

Calibrate pH at 7.00 then 4.00 and conductivity at 2.77 EC. Check ORP with a suitable separate ORP standard at the bottle’s temperature reference; do not treat the supplied pH/EC standards as ORP calibration fluids.

Rinse

Rinse between standards and samples to limit carryover. Remove excess water and bubbles, then wait for stability.

Check

Use fresh, correct standards. A calibration reminder or electrode-condition display supports the routine; it does not replace checking the method.

The right routine, shown by Apera.

Watch the manufacturer’s family tutorial alongside the current Gen II manual. The video is a practical family reference, not proof that every photographed control or accessory is identical across revisions.

Rinse water is not automatically storage liquid.

The GS4-E combo head follows its own humid-cap/long-term KCl routine; do not store it immersed in pure water. Keep GS5-E checking and maintenance specific to the ORP head. The pH slope indicator does not describe platinum ORP-electrode health.

Looking for all parameters at once

This is a probe-change workflow. The ORP head replaces the combo probe, so confirm the installed head and displayed unit before recording.

Comparing different ppm scales

Match 500/700 to the feed chart or use EC. The same solution can legitimately produce different numerical ppm readouts.

Read the slope, not a “life remaining” gauge.

The pH condition figure shown after calibration describes electrode response. It is not a battery indicator, soil-health score or guaranteed percentage of service life left. Use the manual’s cleaning, conditioning and calibration checks before deciding whether to replace the probe.

Calibration markers remind you about the routine. Their disappearance after the documented reminder period is not evidence that the pen has automatically erased calibration.

When a separate field-meter format makes more sense.

If the job is a cabled-probe water-testing workflow rather than a pocket grower pen, compare the alternatives below. These are separate instruments, not plug-in accessories or direct-soil replacements for GS4-P.

Alternative format: Hanna HI99300 portable liquid EC/TDS meter

Related workflow: Hanna HI98195 portable water pH/ORP/EC meter

GS4-P buying and ownership questions

How is GS4-P different from GS4?

GS4-P supplies the GS4 pen/combo probe plus a separate GS5-E ORP probe. The base GS4 kit supports the optional ORP head but does not include it.

Does 6-in-1 mean six separate sensors?

No. It describes pH, EC, two conductivity-derived ppm scales, temperature and an ORP workflow using the separate head. The 500/700 ppm values are conversion scales, not extra chemical sensors.

Can GS4-P measure ORP at the same time as pH and EC?

No. Physically exchange the installed GS4-E for GS5-E to take ORP readings. Do not interpret a kit with two probes as simultaneous acquisition from both.

What is included in AI204G?

The supplied set includes GS4 with combo probe, GS5-E ORP probe, pH 4.00/7.00 buffers, 2.77 EC standard, KCl soaking solution, four installed AAA batteries, lanyard and instructions. ORP checking solution and pH 10.01 are separate.

What ORP specifications are documented?

Apera’s US family catalog lists GS4-P ORP range -1000 to +1000 mV, 1 mV resolution and ±2 mV accuracy. Those catalog terms are not the ±0.2% F.S. expression of a different tester, and no ORP ATC claim is added here.

Why does the same solution show two ppm values?

The 500 and 700 scales calculate different numerical values from the same EC. At 2.6 mS/cm the values are 1300 and 1820 ppm respectively. Match the feed chart’s scale, not just its number.

Does TruRead provide permanent measurement history?

The instructions establish session collection after seven seconds stable and summary average/max/min, not timestamps, retained history or export. Do not assume the same session function is established for every ORP-probe mode.

Which replacements match the supplied setup?

The combo head is GS4-E, AI804G, and the ORP head is GS5-E, AI805G. Follow each probe’s own checking and care instructions; do not apply pH-glass condition percentages to the ORP sensor.

Choose the measurement.
Confirm the supplied probe.

Review the GS4-P kit and specifications, then return to the price and ordering controls. Blue Tiger Scientific can help you match the measurement, sensor and routine before ordering.

Back to price and ordering ↑
    SpecificationDetail
    Brand / familyApera Instruments / GroStar
    Model / catalog numberGS4-P / AI204G
    GenerationGen II; current base-pen guide linked below
    Supplied probe configurationGS4-E / AI804G plus GS5-E / AI805G
    Probe replacementReplaceable
    As-supplied measurementpH, EC, 500ppm, 700ppm and temperature; separate ORP head included
    pH range0.0-14.0 pH
    pH resolution0.1 pH
    pH accuracy±0.1 pH
    pH calibrationAutomatic 1-3 recognized points; follow at least 7.00 then 4.00 routine
    Supplied pH buffers7.00 and 4.00; 10.01 separate
    EC range0-10.0 EC (mS/cm)
    EC resolution0.1 EC
    EC accuracy±0.1 EC
    500ppm scale0-5000 ppm; 10 ppm resolution; ±30 ppm accuracy
    700ppm scale0-7000 ppm; 10 ppm resolution; ±40 ppm accuracy
    ppm conversionEC in mS/cm ×500 or ×700
    EC calibrationOne point at 2.77 EC
    Supplied EC standard2.77 EC (2.77 mS/cm)
    Supplied ORP headGS5-E / AI805G; install in place of standard probe
    ORP range-1000 to +1000 mV, per US family catalog
    ORP resolution1 mV
    ORP accuracy±2 mV, per US family catalog
    ORP checking solutionSeparate; not listed among supplied fluids
    Temperature measurement range0-50°C (32-122°F)
    Temperature resolution0.1°C / 0.1°F
    TruReadStable for 7 seconds then session collection; average/max/min
    Persistent log / exportNot established by reviewed Gen II instructions
    Reading HOLDManual
    Display colorsWhite measurement; green calibration; red calibration error
    ProtectionIP67; close battery cap/O-ring correctly
    Power4 AAA alkaline batteries; installed
    Idle shutoff10 minutes; see manual for disabling
    Storage routineThe GS4-E combo head follows its own humid-cap/long-term KCl routine; do not store it immersed in pure water. Keep GS5-E checking and maintenance specific to the ORP head. The pH slope indicator does not describe platinum ORP-electrode health.

    Ordering Information

    Ordering detailIncluded configuration
    Catalog numberAI204G
    Working kitGS4 pen with GS4-E combo probe and cap, separate GS5-E ORP probe, pH 4.00 and 7.00 buffers (50 mL each), 2.77 EC standard (50 mL), 3M KCl soaking solution (10 mL), four installed AAA batteries, lanyard and instructions.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and ONE YEAR for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    GroStar GS4-P documents

    Use the current Gen II guide for controls, sampling and care. The US catalog adds family/probe/kit comparison; it is not a replacement for the operator instructions. Each card opens a PDF in a new tab.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat