Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Apera GroStar GS1-P Gen II pH/ORP Kit (AI201G) pH/ORP Meter Apera Instruments
Apera GroStar GS1-P Gen II pH/ORP Kit (AI201G) pH/ORP Meter Apera Instruments
Apera GroStar GS1 Gen II pH Pen Kit (AI101G) pH Meter Apera Instruments
Apera GroStar GS1-P Gen II pH/ORP Kit (AI201G) pH/ORP Meter Apera Instruments
Apera GroStar GS1-P Gen II pH/ORP Kit (AI201G) pH/ORP Meter Apera Instruments
Apera GroStar GS1-P Gen II pH/ORP Kit (AI201G) pH/ORP Meter Apera Instruments
Apera GroStar GS1-P Gen II pH/ORP Kit (AI201G) pH/ORP Meter Apera Instruments
Apera GroStar GS1-P Gen II pH/ORP Kit (AI201G) pH/ORP Meter Apera Instruments
Apera GroStar GS1 Gen II pH Pen Kit (AI101G) pH Meter Apera Instruments
Apera GroStar GS1-P Gen II pH/ORP Kit (AI201G) pH/ORP Meter Apera Instruments
Apera GroStar GS1-P Gen II pH/ORP Kit (AI201G) pH/ORP Meter Apera Instruments
Apera GroStar GS1-P Gen II pH/ORP Kit (AI201G) pH/ORP Meter Apera Instruments

Apera GroStar GS1 Gen II pH Pen Kit (AI101G)

$121.00

    Liquid pH, without the extra modes. GroStar GS1 Gen II combines its model-specific sensor setup with a practical calibration routine and TruRead session summaries.

    • Liquid pH and temperature; not a soil spear
    • GS1-E / AI801G replaceable configuration
    • pH 4/7 buffers, KCl and four AAA batteries supplied

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

APERA GROSTAR / GS1 / GEN II / AI101G

Know your solution’s pH.
Keep the routine moving.

A focused pH pen for nutrient solutions and routine aqueous checks. GroStar GS1 Gen II pairs a replaceable double-junction glass probe with a clear calibration workflow and TruRead session statistics.

Choose GS1 when liquid pH is the job. It is not an EC/ppm pen or a direct-soil spear as supplied; those are different sensor choices.

Apera GroStar GS1 manufacturer product photograph
Manufacturer reference photograph. Use the Gen II guide for current controls; image revisions may differ.

±0.1 pH

pH accuracy

0.1 pH resolution; 0.0-14.0 pH range

GS1-E

Replaceable probe

Double-junction glass sensor

TruRead

Session statistics

Average, maximum and minimum

Find your GroStar modelClick or tap to compare all 6 modelsChoose a model below - click or tap here to close

What arrives with AI101G?

GS1 pen with GS1-E pH probe and cap, pH 4.00 and 7.00 buffers (50 mL each), 3M KCl soaking solution (10 mL), four installed AAA batteries, lanyard and instructions.

The supplied-fluid list is separate from optional compatibility: pH 10.01 and any optional ORP head are separate.

Manufacturer GS1 kit or supplied-probe reference
Manufacturer contents reference. Outer packaging can vary; the text checklist identifies the supplied working items.

WHAT THIS MODEL IS BUILT TO ANSWER

Where GS1 belongs in the routine.

Nutrient solution and irrigation water

Keep pH checks distinct from EC/ppm checks. A pH reading answers an acidity question; it does not measure nutrient concentration.

Repeatable sampling

Use a consistent sample, rinse routine and calibration sequence. TruRead helps summarize several stable readings instead of choosing one convenient result.

Liquid pH before soil pH

Use GS1’s supplied bulb probe for suitable liquids. Choose the GS2 spear configuration for direct moist-soil or growing-media work.

Choose the contact, not just the model number.

Supplied probe: GS1-E / AI801G. The base sensor is double-junction glass for liquid pH.

Replaceability gives the worn sensor a maintenance path; it is not an unlimited service-life guarantee. Install, condition and calibrate the correct head according to its instructions.

GroStar GS1 supplied sensing probe detail
Sensing surfaces and care instructions are probe-specific.

A SESSION SUMMARY, NOT A CLOUD LOGGER

Read several spots.
See the spread, not just one number.

In the documented Gen II TruRead workflow, a reading that has stayed stable for seven seconds is recorded for the session. Review the average, maximum and minimum after collecting your measurements. Seven seconds of stability is not the same as a fixed seven-second sampling interval.

6.2 pH

Illustrative minimum

6.3 pH

Illustrative average

6.4 pH

Illustrative maximum

The three illustrative values explain the summary; they do not prescribe a fixed sample count. The reviewed instructions do not establish retained history, timestamps or export. Use a suitable logger if those are requirements.

Calibrate the sensor you are actually using.

Start at pH 7.00, then complete pH 4.00 without switching off between points. The pen recognizes 1-3 points, but the manual calls for at least a two-point routine. pH 10.01 is a separate third-point buffer.

Rinse

Rinse between standards and samples to limit carryover. Remove excess water and bubbles, then wait for stability.

Check

Use fresh, correct standards. A calibration reminder or electrode-condition display supports the routine; it does not replace checking the method.

The right routine, shown by Apera.

Watch the manufacturer’s family tutorial alongside the current Gen II manual. The video is a practical family reference, not proof that every photographed control or accessory is identical across revisions.

Rinse water is not automatically storage liquid.

For daily or weekly pH use, keep the cap humid with a few droplets and tightly closed. For longer storage, follow the manual’s 3M KCl cap-fill routine. Rinse between samples; never store the glass probe immersed in tap, RO, distilled or deionized water.

The result drifts

Check fresh buffers, hydration and sample conditions before blaming the pen. A poorly buffered or low-ionic sample can take longer than a normal buffer.

The slope percentage looks low

It describes the pH electrode’s response after calibration, not battery charge or a guaranteed percentage of remaining life. Clean, condition and recalibrate as the manual directs.

Read the slope, not a “life remaining” gauge.

The pH condition figure shown after calibration describes electrode response. It is not a battery indicator, soil-health score or guaranteed percentage of service life left. Use the manual’s cleaning, conditioning and calibration checks before deciding whether to replace the probe.

Calibration markers remind you about the routine. Their disappearance after the documented reminder period is not evidence that the pen has automatically erased calibration.

When a separate field-meter format makes more sense.

If the job is a cabled-probe water-testing workflow rather than a pocket grower pen, compare the alternatives below. These are separate instruments, not plug-in accessories or direct-soil replacements for GS1.

Alternative format: Hanna HI99300 portable liquid EC/TDS meter

Related workflow: Hanna HI98195 portable water pH/ORP/EC meter

GS1 buying and ownership questions

GS1 or GS2: which should I choose?

GS1 ships with a liquid pH bulb probe; GS2 ships with a soil/media spear, dibber and brush. Choose the sample-contact method first. Do not force GS1’s supplied bulb into soil.

What comes in GS1 AI101G?

The kit supplies GS1 with GS1-E, pH 4.00 and 7.00 buffers, KCl soaking solution, four installed AAA batteries, lanyard and instructions. The text checklist defines supplies; outer packaging can vary.

What are the pH range and accuracy?

GS1 measures 0.0-14.0 pH with 0.1 pH resolution and ±0.1 pH accuracy. Use it when that capability fits the procedure rather than assuming more displayed digits.

Does GS1 measure EC, ppm or ORP out of the box?

It measures pH and temperature with the supplied probe. No EC/ppm sensor or ORP probe is supplied in the base GS1 kit. GS5-E ORP capability requires the separate compatible probe; GS1-P is the pH-plus-ORP kit.

What does TruRead save?

The Gen II manual describes readings collected after seven seconds of stability and session average, maximum and minimum. It does not establish persistent saved history, timestamps or export. Treat it as a session-summary tool, not a data logger.

Which calibration buffers are included?

pH 7.00 and 4.00 are supplied. Start at 7.00 and follow with 4.00 without powering off. pH 10.01 is separate for an appropriate third point; a recognized point is not automatically a supplied bottle.

What does the electrode-condition percentage mean?

It is pH electrode slope reported after calibration, not soil health, battery status or a remaining-life guarantee. Use the manual’s condition guidance and cleaning/recalibration steps.

How do I store GS1?

Keep the pH glass hydrated under the model’s humid-cap or KCl storage instructions. Do not immerse-store in pure water. Use the exact GS1-E replacement, AI801G, when replacement is needed.

Choose the measurement.
Confirm the supplied probe.

Review the GS1 kit and specifications, then return to the price and ordering controls. Blue Tiger Scientific can help you match the measurement, sensor and routine before ordering.

Back to price and ordering ↑
    SpecificationDetail
    Brand / familyApera Instruments / GroStar
    Model / catalog numberGS1 / AI101G
    GenerationGen II; current base-pen guide linked below
    Supplied probe configurationGS1-E / AI801G
    Probe replacementReplaceable
    As-supplied measurementpH and temperature
    pH range0.0-14.0 pH
    pH resolution0.1 pH
    pH accuracy±0.1 pH
    pH calibrationAutomatic 1-3 recognized points; follow at least 7.00 then 4.00 routine
    Supplied pH buffers7.00 and 4.00; 10.01 separate
    Optional ORPGS5-E separate; not supplied in this base kit
    Temperature measurement range0-50°C (32-122°F)
    Temperature resolution0.1°C / 0.1°F
    TruReadStable for 7 seconds then session collection; average/max/min
    Persistent log / exportNot established by reviewed Gen II instructions
    Reading HOLDManual
    Display colorsWhite measurement; green calibration; red calibration error
    ProtectionIP67; close battery cap/O-ring correctly
    Power4 AAA alkaline batteries; installed
    Idle shutoff10 minutes; see manual for disabling
    Storage routineFor daily or weekly pH use, keep the cap humid with a few droplets and tightly closed. For longer storage, follow the manual’s 3M KCl cap-fill routine. Rinse between samples; never store the glass probe immersed in tap, RO, distilled or deionized water.

    Ordering Information

    Ordering detailIncluded configuration
    Catalog numberAI101G
    Working kitGS1 pen with GS1-E pH probe and cap, pH 4.00 and 7.00 buffers (50 mL each), 3M KCl soaking solution (10 mL), four installed AAA batteries, lanyard and instructions.
    Order unit1 kit

    Warranty Information

    APERA INSTRUMENTS, LLC warrants this instrument to be free from defects in material and workmanship and agree to repair or replace free of charge, at the option of APERA INSTRUMENTS, LLC, any malfunctioned or damaged product attributable to the responsibility of APERA INSTRUMENTS, LLC for a period of TWO YEARS for the instrument and ONE YEAR for the probe from the delivery.

    This limited warranty does NOT cover any issues due to:

    • Accidental damage
    • Improper use
    • Normal wear and tear
    • Transportation
    • Storage
    • Failure to follow the product instructions
    • Unauthorized maintenance, modifications, combination or use with any products, materials, processes, systems or other matter
    • Unauthorized repair
    • External causes such as accidents, abuse, or other actions or events beyond our reasonable control.

    GroStar GS1 documents

    Use the current Gen II guide for controls, sampling and care. The US catalog adds family/probe/kit comparison; it is not a replacement for the operator instructions. Each card opens a PDF in a new tab.