Skip to content
Purair BIO Class II A2 Biological Safety Cabinet 3-6Ft Class II Type A2 Biosafety Cabinet Air Science
Purair BIO Class II A2 Biological Safety Cabinet 3-6Ft Class II Type A2 Biosafety Cabinet Air Science
Purair BIO Class II A2 Biological Safety Cabinet 3-6Ft Class II Type A2 Biosafety Cabinet Air Science
Purair BIO Class II A2 Biological Safety Cabinet 3-6Ft Class II Type A2 Biosafety Cabinet Air Science
Purair BIO Class II A2 Biological Safety Cabinet 3-6Ft Class II Type A2 Biosafety Cabinet Air Science
Purair BIO Class II A2 Biological Safety Cabinet 3-6Ft Class II Type A2 Biosafety Cabinet Air Science
Purair BIO Class II A2 Biological Safety Cabinet 3-6Ft Class II Type A2 Biosafety Cabinet Air Science
Purair BIO Class II A2 Biological Safety Cabinet 3-6Ft Class II Type A2 Biosafety Cabinet Air Science

Purair BIO Class II A2 Biological Safety Cabinet 3-6Ft

$7,295.00

    Please note: This product is made to order, and may carry up to 3-6 weeks lead times.

    Upgrade your lab with the Purair BIO Class II, Type A2 Biosafety Cabinet, available in 36", 48", and 72" sizes. Designed to exceed safety standards, it offers unmatched containment for handling biosafety agents. Its ergonomic, space-efficient design and advanced HEPA filtration ensure maximum protection for you, your samples, and the environment. Equip your lab with the pinnacle of biosafety and performance

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Purair® Bio Class II A2 Biological Safety Cabinets are NSF Listed and designed for optimum performance at 115V 60Hz. Each cabinet comes equipped with an Adjustable Height Base Stand on Levelers for flexibility and stability, a UV system for enhanced sterilization, two GFI outlets for added convenience, and one service fixture to meet all your laboratory needs.

 

The Purair BIO is a state-of-the-art Class II, Type A2 biosafety cabinet designed to meet stringent US and international standards, including NSF/ANSI 49. Available in 36", 48", and 72" sizes, it provides primary containment for handling biosafety agents at levels 1, 2, and 3. Its ergonomic design ensures ease of use, making it one of the narrowest BSCs on the market, which allows for easy passage through standard doorways.

The Purair BIO features a single EC blower motor for reliable performance and lower maintenance costs. Enhanced protection is ensured with HEPA filtration of both downflow and exhaust paths, protecting the user, the work product, and the environment from cross-contamination. The cabinet also includes a user-friendly interface with a 10° angled window to reduce operator discomfort and fatigue.

Additionally, it can be equipped with a range of accessories to enhance its functionality and adaptability to various laboratory needs. Options include an exhaust plenum, IV bar hooks, and other optional components tailored to specific applications and requirements.

 

    Model Voltage NSF 49 EN12469 IEC61010-1 Protection Dimensions Weight (LBS/KG)
    3 ft. | AS-AHA-103-CA-B 115V, AC, 60Hz No No Yes Yes (Particulates), When ducted to outside (Vapors) Internal: 36.2" × 24.6" × 28" (920 × 626 × 709 mm)
    External: 40.7" × 31.1" × 60.5" (1034 × 789 × 1537 mm)
    Shipping: 43.3" × 33.5" × 77.8" (1100 × 850 × 1950 mm)
    Net: 463 lbs / 210 kg
    Ship: 529 lbs / 240 kg
    3 ft. | AS-AHA-103-CB-B 230V, AC, 50Hz No No Yes Yes (Particulates), When ducted to outside (Vapors) Internal: 36.2" × 24.6" × 28" (920 × 626 × 709 mm)
    External: 40.7" × 31.1" × 60.5" (1034 × 789 × 1537 mm)
    Shipping: 43.3" × 33.5" × 77.8" (1100 × 850 × 1950 mm)
    Net: 463 lbs / 210 kg
    Ship: 529 lbs / 240 kg
    4 ft. | AS-AHA-133-CA-A 115V, AC, 60Hz No Yes Yes Yes (Particulates), Yes** (Vapors) Internal: 48" × 24.6" × 28" (1220 × 626 × 709 mm)
    External: 52.5" × 31.1" × 60.5" (1334 × 789 × 1537 mm)
    Shipping: 55.1" × 33.5" × 77.8" (1400 × 850 × 1950 mm)
    Net: 529 lbs / 240 kg
    Ship: 617 lbs / 280 kg
    4 ft. | AS-AHA-133-CB-A 230V, AC, 50Hz No Yes Yes Yes (Particulates), Yes** (Vapors) Internal: 48" × 24.6" × 28" (1220 × 626 × 709 mm)
    External: 52.5" × 31.1" × 60.5" (1334 × 789 × 1537 mm)
    Shipping: 55.1" × 33.5" × 77.8" (1400 × 850 × 1950 mm)
    Net: 529 lbs / 240 kg
    Ship: 617 lbs / 280 kg
    4 ft. | AS-AHA-133-CA-B 115V, AC, 60Hz Yes Yes Yes Yes (Particulates), When ducted to outside (Vapors) Internal: 48" × 24.6" × 28" (1220 × 626 × 709 mm)
    External: 52.5" × 31.1" × 60.5" (1334 × 789 × 1537 mm)
    Shipping: 55.1" × 33.5" × 77.8" (1400 × 850 × 1950 mm)
    Net: 529 lbs / 240 kg
    Ship: 617 lbs / 280 kg
    5 ft. | AS-AHA-153-CA-B 115V, AC, 60Hz No Yes Yes Yes (Particulates), Yes** (Vapors) Internal: 60" × 24.6" × 28" (1524 × 626 × 709 mm)
    External: 65.5" × 31.1" × 60.5" (1664 × 789 × 1537 mm)
    Shipping: 68.1" × 33.5" × 77.8" (1730 × 850 × 1950 mm)
    Net: 794 lbs / 360 kg
    Ship: 882 lbs / 400 kg
    6 ft. | AS-AHA-163-CA-B 115V, AC, 60Hz No Yes Yes Yes (Particulates), Yes** (Vapors) Internal: 72" × 24.6" × 28" (1829 × 626 × 709 mm)
    External: 77.5" × 31.1" × 60.5" (1968 × 789 × 1537 mm)
    Shipping: 80.1" × 33.5" × 77.8" (2035 × 850 × 1950 mm)
    Net: 882 lbs / 400 kg
    Ship: 970 lbs / 440 kg

    * 99.99% @ 0.3 microns
    ** 4 ft. EN versions have a 20 cm window position, all other models have a 25 cm window position.

    Air Science Return and Cancellation Policy of Shipped Products

    • Return Authorizations are only allowed for standard, non-customized, products in brand new, unopened, unused condition and in the original packaging, within 30 days of the ship date. Custom or modified products cannot be cancelled or returned. Consumables, such as filters, regardless of condition, cannot be returned.

    Return and Cancellation Conditions

    • A restocking fee of 25% will apply to all items being returned.
    • The customer will pay all shipping charges to and from Air Science USA LLC regardless of if they we’re included in original unit price or offered at no charge with the purchase.
    • Goods damaged as a result of shipping cannot be returned. You will need to follow our damage claims policy below.
    • Any damage as a result from improper customer handling or packaging cannot be returned or accepted by Air Science USA LLC.

    Damaged Freight Claim Information

    Caution: Inspect each shipment very carefully before acceptance.Claims for loss or damage sustained in transit must be filed with the carrier.

    • Please remember that you are responsible for all freight claims and the cost of all replacement pieces for each shipment you accept.
    • Carefully inspect each pallet or crate upon arrival. If a shipment is found to be damaged upon delivery you must have the driver/carrier document all damage details on the delivery receipt. This is essential or your claim may be denied.
    • Keep all damaged items and packing material until claim is resolved between you and the carrier. Pictures of freight should also be taken.
    • If pallets are stacked, please note “Stacked Pallets” on the delivery receipt (pallets are normally not stacked when shipped).

    If freight damage is discovered, please refer to the following guidelines in order to process an effective freight claim.

    Accepted Freight with Noted Visible Loss or Damage

    Any external evidence of loss or damage must be noted on the freight bill or delivery receipt and signed by the courier’s agent or delivery driver. NOTE: Failure to properly describe evidence of loss or damage may result in the carrier refusing to honor a claim.

    • Contact delivering terminal to initiate a claim form and inspection.
    • Notify Blue Tiger Scientific or Air Science USA LLC.

    Accepted Freight with Concealed Loss or Damage

    In the event of accepted freight with concealed damage or loss, notification of loss or damage must be sent to the carrier within 48 Hours of receiving the freight to initiate a claim and obtain a claim number. Notification outside the 48 Hour time frame may result in denial of the damage claim.

    • Contact the carrier immediately upon discovery of damage and request an inspection by the carrier’s agent.
    • Carrier will determine inspection needs based on value and time elapsed.
    • Notify Blue Tiger Scientific or Air Science USA LLC.

    Unaccepted Freight

    If substantial damage is noted upon inspection you have the right to refuse part or all of a shipment.NOTE: Any correspondence with Air Science regarding loss or damage must be accompanied by a copy of the shipping carrier’s report. Air Science will not accept returns that have not been authorized.

    Shortage/Discrepancies

    • Compare to packing list to note shortage or discrepancy
    • Shortage or discrepancy must be reported in 5 days of receiving shipment. Notification outside the 5 day time frame will not be accepted.

    Return Authorization Requirement

    Before returning any product, you must contact the Air Science Service Department to obtain a “Return Authorization Number (RA)”. The following information must be made available when submitting a Return Authorization request.

    • Model number
    • Serial number
    • Contact name
    • Contact phone number
    • Description of the problem with the unit.

    The Return Authorization number must always appear on the packing slip and on the outside of the returned freight or package to avoid processing delays or refusal of delivery.

    Cancellation of Product Before Shipping Policy

    Standard products and filters can be cancelled at no charge only before they have shipped. Custom products cannot be cancelled after released into production and/or approval of drawings.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)