Skip to content
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator Default Title BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator Default Title BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold

Accucold ABOD6 6 Cu. Ft. BOD Refrigerated/Heated Incubator

Model / SKU ABOD6

$2,965.00 USDStandard delivery calculated at checkout for the contiguous US and DC

$2,965.00

    Controlled conditions for BOD water-sample incubation.

    6 cu. ft. (170 L) nominal capacity with 4 adjustable wire shelves.

    4 to 60°C adjustable control range; factory preset to 20°C.

    Glycol-buffered sensing and local alarms standard; calibrated recording optional.

  • Standard dock or liftgate delivery to the contiguous US and DC is calculated at checkout.
  • Alaska, Hawaii and US territories require a quote.
  • Base equipment only. Factory options, racks and monitoring configurations require a quote.
  • Inside placement, stairs and white-glove services are reviewed and quoted separately for your approval.
Need inside delivery or white-glove service?

Please choose one. No surcharge is added here; additional services require a separate quote and your approval.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

BOD refrigerated / heated incubation · ABOD6

Build a compact, dedicated water-sample incubation station.

The Accucold ABOD6 gives water treatment, environmental and microbiology laboratories a 6 cu. ft. dedicated chamber for sample incubation. Its 4 to 60°C adjustable control range supports refrigerated and heated operation, with a factory preset of 20°C for bottle incubation. Establish the required conditions for your method rather than treating the preset as the full range.

4 adjustable shelves help organize sample batches while keeping the external temperature display in view.

ABOD6 OEM bottle-loading illustration; bottles not included
Authentic manufacturer loading illustration. Bottles and contents are not included.
6 cu. ft.Nominal chamber capacity
4 to 60°CFull adjustable control range
20°CFactory preset, not range limit

Application-led sample organization

Plan the bottle sequence before the chamber fills.

Use a repeatable shelf map for sample groups and incubation schedules. The manufacturer lists capacity for up to 90 300 mL glass incubation bottles, depending on exact bottle design and size. Check your own vessels and working clearances rather than treating nominal volume as a guaranteed batch size.

Set the shelf map

4 plastic-coated wire shelves adjust in 1/2-inch increments. Orient the front lip for smaller vessels or reverse it to create a flat shelf position.

Preserve circulation

Forced-air circulation and adjustable-cycle automatic defrost support chamber operation. Leave space around bottles, keep the fan area clear and follow the manual loading guidance.

Control access

The standard solid door includes a keyed lock and two keys. The silver-ion-coated handle and powder-coated metal interior are practical cabinet details, not a substitute for laboratory cleaning procedures.

ABOD6 OEM glycol-buffered sensing probe, not a calibrated logger
The included display probe sits in a glycol-filled bottle. Independent recording equipment is optional.

Sensing and response

Separate chamber control from your recordkeeping plan.

A glycol-buffered display probe helps represent stored-product temperature. A second sensor reads chamber air for temperature control. The external microprocessor controller provides current and resettable minimum/maximum readings, with Celsius/Fahrenheit capability already included.

High/low temperature, sensor-failure, door-open and power-failure alarms support a defined response routine. The battery-powered power-failure alarm does not run the cooling or heating system. Rear volt-free dry contacts require a separate external alarm system; they are not an activated cloud notification service.

Commission the actual configuration

Verify settings before the first sample batch.

The BOD manual calls for at least two hours upright before connecting power and at least 24 hours of running stabilization before use. Review setpoint, alarms, shelf layout and independent measurements for your method before loading samples.

The factory probe-access opening supports additional monitoring equipment. Confirm fitting dimensions before selecting probes, and verify the installed door-alarm delay during commissioning.

ABOD6 complete OEM front view showing external controller and solid door
Complete manufacturer front view. The controller is at the top of the cabinet; this is not an invented control close-up.

Standard equipment versus factory options

Request one complete, reviewed incubator configuration.

Use the configuration choices for a proposal covering the complete ABOD6, not loose-installed component costs. The current manufacturer AVAILABLE UPGRADES list includes DL2B, DLPWINC, LHD, DTFAR and KAL only. Combined installation, final lead time and pricing require review before purchase.

Configuration What it means
Standard sensing Glycol-buffered display probe, air sensor, local alarms and dry contacts. A min/max display is not a downloadable temperature log.
DL2B Listed factory NIST-calibrated USB logger with internal memory, configurable recording intervals and high/low alarm. Confirm probe and calibration range at the intended setpoint.
DLPWINC Listed factory NIST-calibrated wireless environmental monitoring for cloud data management. Confirm range, connectivity, activation and service terms.
LHD / DTFAR / KAL Factory left-hand door request, Fahrenheit readout setup or battery-powered self-locking keypad lock. The base controller already supports Fahrenheit; the base door already has a keyed lock.

No full-range logger compatibility is promised. In particular, request written confirmation for operation and calibration at 60°C. The existence of a listed option does not establish every combination or setpoint as validated.

Will it fit?

Plan the chamber, door arc and ventilation together.

The cabinet is 32.5 H × 23.38 W × 24.38 D inches. Depth increases to 26.13 inches with the handle and 46.5 inches with the door at 90°. Published width with the door open is 23.88 inches.

ABOD6 cabinet dimensions with labelled navy height, green width and orange depth arrows: 32.5 inches high, 23.38 inches wide, 24.38 inches cabinet depth.
Height: 32.5 in.Width: 23.38 in.Cabinet depth: 24.38 in.
Tap the diagram to enlarge. Cabinet height: 32.5 inches. Freestanding indoor use only. Maintain at least 5 inches at the rear, top and each side; keep the front unobstructed. Depth with handle: 26.13 inches. Depth with door open 90°: 46.5 inches. Confirm final setup, packed dimensions and installation clearances separately.

This is an indoor freestanding incubator, not a built-in model. The BOD manual requires at least 5 inches at the rear, top and each side, with the front unobstructed. A short cabinet is not automatically suitable for an enclosed counter opening. Keep the probe access and rear alarm terminals accessible.

The published supply is 115 V AC, 60 Hz. Confirm the installed nameplate, heating load and circuit requirements with Accucold before site electrical planning. Use an exclusive, properly grounded outlet and follow the supplied instructions.

Receiving and setup

Measure the packed route as well as the installation site.

Manufacturer unit weight is listed at 115 lb on the current page. The provided manufacturer export lists 153 lb packed shipping weight and 44 H × 31 W × 31 D inches packed. These are separate measurements. Confirm the final package, unloading arrangements, turns, doorways and any elevator before receipt.

FSI lists LTL freight service with supplier overboxing and a custom skid for this model. Checkout retains the original dock-delivery and liftgate options for eligible orders. Multiple-unit or mixed-equipment orders may use freight services. Alaska, Hawaii, US territories and international destinations require a quote.

ABOD6 authentic OEM angled cabinet photograph
Cabinet dimensions are not packed dimensions or installation clearances.

Buyer questions

Nine details for a more complete equipment decision.

What is ABOD6 designed to incubate?

It is purpose-built for BOD water samples and microbiological laboratory applications in water treatment centers, environmental laboratories and research facilities. Select protocols and verify conditions for your samples; this is laboratory incubation equipment, not a general food-storage appliance.

Is 20°C the full temperature range?

No. The factory preset is 20°C, while the adjustable control range is 4 to 60°C (39.2 to 140°F). Set and verify the required temperature and alarms before loading samples.

How many bottles and shelves can I plan for?

The manufacturer lists 4 adjustable plastic-coated wire shelves and up to 90 300 mL incubator glass bottles. Actual bottle capacity depends on design and size. Preserve airflow and validate your shelf layout; bottles are not included.

Is a calibrated temperature logger included?

No. The standard glycol-buffered display probe and separate air sensor support cabinet sensing and control. DL2B USB logging and DLPWINC wireless environmental monitoring are manufacturer-listed factory options. Confirm logger probe range, calibration scope, installation and any service terms for your intended setpoint, especially 60°C, before purchase.

Do rear alarm contacts provide an activated alert service?

No. The volt-free contacts require a separate external alarm system. The battery-powered power-failure alarm sounds locally for a limited time; it does not run refrigeration or heating. Assign a response routine and verify the installed alarm settings.

Can it be installed under a counter or inside cabinetry?

It is a freestanding indoor model, not a built-in appliance. The BOD manual requires at least 5 inches at the back, top and each side, with the front unobstructed. Cabinet height alone does not establish an approved installation opening.

Can the solid door be reversed?

The standard door ships right-hinged and self-closing. Reversing the base door following the manual removes self-closing. The manual says -DL2B data-logger doors are not user-reversible. Request factory LHD and monitoring together if a left-hand arrangement is needed.

Which weight and connection details should my facility use?

The manufacturer lists a 115 lb unit weight; packed shipping weight is 153 lb. Use packed measurements for receiving. Confirm the nameplate, heating load and probe fittings before circuit planning or selecting monitoring equipment.

Who handles manufacturer warranty service?

Accucold/FSI handles manufacturer warranty and authorized repairs directly. The written warranty provides two-year limited parts and labor coverage in the 48 contiguous US states and five-year compressor replacement without labor, subject to its terms. Confirm other destinations directly. Blue Tiger manages purchase and order-return requests.

Complete equipment proposal

Bring the sample method and site plan together.

Review ABOD6 capacity, setpoint, recording requirements, final door swing and receiving needs in one equipment proposal.

    SpecificationDetails
    Brand / modelAccucold / ABOD6
    Equipment typeBOD refrigerated/heated incubator for laboratory sample incubation
    Nominal capacity6 cu. ft. (170 L), current model page; confirm usable load layout
    Adjustable control range4 to 60°C (39.2 to 140°F)
    Factory preset20°C; distinct from the full adjustable range
    Published bottle capacityUp to 90 300 mL incubator glass bottles; varies with exact bottle design and size; bottles not included
    Cabinet height × width × depth32.5 × 23.38 × 24.38 in.
    Depth with handle26.13 in.
    Depth with door at 90°46.5 in.
    Width with door open23.88 in.
    Interior height × width × depth24.5 × 20 × 17 in.; compressor step 6.5 H × 20 W × 5 D in.
    Shelving4 adjustable plastic-coated wire shelves; 1/2-inch positioning increments
    DoorWhite solid door; right-hand self-closing standard. Base door is user-reversible; reversal removes self-closing. -DL2B doors are not user-reversible.
    Lock / handle / interiorFactory keyed lock with two keys; silver-ion-coated handle; white powder-coated metal interior
    LightingLED interior light with internal switch
    Temperature sensingDisplay probe in glycol-filled bottle plus separate air/control sensor
    Control / displayExternal digital microprocessor controller; current and resettable min/max temperature; Celsius/Fahrenheit capability standard
    AlarmsHigh/low temperature, sensor failure, door-open and battery-powered power-failure alarm. Alarm battery does not power refrigeration or heating. Verify door-alarm delay during commissioning.
    Remote alarm connectionsRear volt-free dry contacts; separate external alarm system required
    Probe accessFactory probe-access opening for additional monitoring equipment; confirm supplied opening and fitting compatibility before ordering probes.
    Cooling / defrostForced-air circulation; automatic adjustable-cycle defrost
    InstallationIndoor freestanding use; not built-in. At least 5 inches at rear, top and each side; keep front unobstructed.
    CommissioningAllow at least 2 hours upright before connecting; run and stabilize at least 24 hours before use, per BOD manual.
    Electrical supply115 V AC / 60 Hz; hospital-grade cord with green-dot plug. Confirm installed nameplate, heating load and circuit requirements before site planning.
    RefrigerantR600a. Refrigerant service and charge must follow the installed unit nameplate and manufacturer instructions.
    Sound level, current product page40.7 dB
    Manufacturer unit weight, current product page115 lb; not packed shipping weight
    Packed shipping weight153 lb; provided manufacturer export
    Packed shipping height × width × depth44 × 31 × 31 in.; confirm final packaging
    Manufacturer freight group7
    Electrical safety listingsETL (US), ETL-C (Canada)
    Manufacturer limited warranty2 years parts and labor in the 48 contiguous US states under written terms and designated service; 5-year compressor replacement excludes labor. Confirm geographic coverage with Accucold/FSI.
    UPC761101150949

    Blue Tiger Scientific is a reseller, not the manufacturer. We manage your purchase and order-return requests. Accucold, a division of Felix Storch, Inc. (FSI), handles manufacturer warranty coverage, service and repairs directly.

    Ordering and delivery

    Availability, dispatch timing and freight depend on the selected equipment, configuration and destination. Delivery dates shown on this page are estimates, not guarantees. Supplier processing, lead time and carrier transit can affect arrival. Contact Blue Tiger before ordering if you have a firm deadline or specific receiving requirements.

    For the base equipment, standard dock or liftgate delivery charges to the 48 contiguous United States and Washington, DC are calculated at checkout. Select dock delivery only if a suitable receiving dock and unloading capability are available. Alaska, Hawaii, US territories and international destinations require a quote. Measure the complete access route and prepare the installation site using the manufacturer’s instructions.

    Standard delivery does not include inside placement, stairs or white-glove services. If additional services are needed, Blue Tiger Scientific will review access, elevators, delivery level and placement requirements and provide a separate quote for your approval before any additional service charge is billed.

    The current manufacturer product page and BOD manual differ in some technical details, including electrical current, access-port size and door-alarm delay. Confirm the supplied nameplate, probe connections and alarm settings with Accucold before installation. Recording-option operating and calibration ranges must be confirmed for the intended incubation setpoint.

    Inspect your delivery

    Inspect the shipment when it arrives. Keep the original cartons, packing materials and delivery paperwork. Report damage, shortages or an incorrect item to Blue Tiger immediately at info@bluetigerscientific.com, with photographs of the item, packaging, shipping label and delivery receipt.

    For freight arranged by FSI or delivered on FSI trucks, FSI instructs recipients to refuse visibly damaged units and have the driver record and acknowledge the damage on the delivery paperwork. On a multi-unit shipment, refuse the damaged units rather than the undamaged remainder. Concealed damage must be reported within five days after delivery acceptance; contact Blue Tiger immediately so the manufacturer’s reporting deadline can be met.

    For customer-nominated, collect or third-party-carrier shipments, claims must be pursued with that carrier. Do not assume FSI will accept a freight-damage return. Contact Blue Tiger for the order information and instructions before arranging any return shipment.

    Order returns must start with Blue Tiger

    All order-return requests must be initiated through Blue Tiger Scientific at info@bluetigerscientific.com. Accucold/FSI does not provide an automatic buyer’s-remorse return right. Eligibility and written authorization must be confirmed before anything is shipped.

    • Contact Blue Tiger within 14 days of delivery to request review, subject to the product-specific manufacturer restrictions. FSI does not accept an eligible factory-sealed return after 30 days from its original shipment date, so request review promptly enough for an authorized return to meet that deadline.
    • Include your Blue Tiger order number, exact manufacturer part number, serial number if applicable, quantity, contact details and reason for the request. Provide the photographs required for the manufacturer’s review.
    • Wait for written return authorization and the designated return address. Do not send an order return to Blue Tiger’s business address or directly to FSI without these instructions.
    • For an eligible non-defective stock return, FSI requires the original unopened carton and an undamaged appliance in new condition. Opened packages are not accepted under that return route.
    • FSI applies a 25% restocking charge per eligible returned item and may charge a higher percentage on larger orders. Your authorization will state the applicable charges. Original outbound freight, including embedded freight on a shipment, reduces the return credit.
    • The customer is responsible for approved non-defective return freight and insurance. Use the authorized carrier and instructions supplied for this heavy equipment. Damage, incorrect-item and defect reports are reviewed separately from an unwanted-product request.

    Customized and factory-upgraded equipment

    FSI excludes made-to-order models with customizations from ordinary returns. Its listed exclusions include factory-installed thermometers, alarms, data loggers and digital-thermostat upgrades, as well as specified lock, door and cabinet customizations. Do not assume a factory-upgraded configuration is returnable. Confirm the exact model’s eligibility before ordering.

    Manufacturer warranty and service go directly to Accucold

    The ABOD6 manufacturer documentation lists two-year limited parts and labor coverage within the 48 contiguous United States when operated and maintained as instructed and serviced by a designated company. Five-year compressor replacement does not include labor. Confirm destination coverage directly with Accucold/FSI; do not assume worldwide on-site service.

    Contact Accucold/FSI directly for warranty coverage questions, claims, service assignment and repair authorization: service@accucold.com or 718-893-3900. Technical questions can be directed to techsupport@accucold.com. Have your model, serial number, proof of purchase, delivery location and a description of the problem ready.

    Blue Tiger Scientific does not administer manufacturer warranty claims, authorize warranty repairs or provide warranty service. Do not commission an independent repair or send equipment for service until FSI provides authorization and instructions. Service not assigned or authorized by FSI may not be covered.

    Manufacturer coverage depends on proper installation, operation and maintenance. The written warranty includes exclusions for matters such as misuse, improper installation, unauthorized modifications and consequential losses, including product spoilage. Equipment warranty coverage is not a guarantee of stored-material value or reimbursement.

    International destinations and service areas

    International customers should request a quote to confirm the equipment configuration, destination eligibility and shipping arrangements. Confirm responsibility for any import duties, taxes and brokerage in the quote. International returns are not permitted under Blue Tiger Scientific’s published return policy.

    Warranty coverage and service arrangements vary by model and destination. Contact Accucold/FSI directly before purchase to confirm service for your exact delivery location. Do not assume worldwide on-site service is included.

Questions about a product? Ask us here.