Skip to content
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator Default Title BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator Default Title BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold
Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator BOD Refrigerated/Heated Incubators Accucold

Accucold ABOD18 18 Cu. Ft. BOD Refrigerated/Heated Incubator

Model / SKU ABOD18

$6,065.00 USDStandard delivery calculated at checkout for the contiguous US and DC

$6,065.00

    Give water-sample incubation a dedicated, adjustable environment.

    18 cu. ft.; 4 to 60°C; factory preset 20°C; seven adjustable shelves.

    Included controller, buffered sensing and alarms; calibrated USB or wireless logging optional.

    Freestanding indoor installation only. Allow at least 5 inches at the top, rear and each side, and keep the front air vent unobstructed. The applicable BOD manual reserves built-in or recessed installation for models with a -BI suffix; ABOD18 is not such a model.

  • Standard dock or liftgate delivery to the contiguous US and DC is calculated at checkout.
  • Alaska, Hawaii and US territories require a quote.
  • Base equipment only. Factory options, racks and monitoring configurations require a quote.
  • Inside placement, stairs and white-glove services are reviewed and quoted separately for your approval.
Need inside delivery or white-glove service?

Please choose one. No surcharge is added here; additional services require a separate quote and your approval.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

BOD incubation, environmental research and microbiology / ABOD18

Give water-sample incubation a dedicated, adjustable environment.

The Accucold ABOD18 combines an 18 cu. ft. upright chamber with refrigerated and heated operation from 4 to 60°C. It arrives preset to 20°C for bottle incubation, with seven adjustable wire shelves, external digital controls and a solid, lockable door. It is designed for water treatment centers, environmental laboratories and microbiological research, not as a vaccine refrigerator.

ABOD18 OEM angled cabinet
Original OEM product photograph. Contents shown in storage examples are not included.
18 cu. ft.Published chamber capacity
4 to 60°CRefrigerated and heated range
20°CFactory preset

Application and workflow

A dedicated home for the materials that match the range.

An 18 cu. ft. chamber makes room for sample batches without tying up smaller incubators. Use a repeatable shelf map to separate incoming and active batches. Automatic adjustable-cycle defrost and forced-air circulation support routine operation; establish and verify the conditions required by each protocol before loading.

Use ABOD18 for environmental water-sample storage and incubation, including BOD and microbiology workflows within its published 4 to 60°C range. The 20°C preset is a starting configuration, not proof that a particular test method, load or facility has been validated. No vaccine-storage, CDC approval or NSF certification claim is made for this incubator.

ABOD18 OEM manufacturer incubation-bottle storage example; bottles not included
OEM bottle-storage example. Exact capacity varies with bottle design and size.

Interior planning

Build a repeatable sample layout.

Seven plastic-coated wire shelves adjust at 1/2-inch increments, letting staff organize bottle sizes while preserving air circulation. Accucold states capacity for up to 300 300 mL incubation bottles, with actual capacity dependent on bottle design and size. Check your own bottle dimensions, shelf loading and workflow rather than treating the count as guaranteed.

LED lighting has an internal on/off switch. The durable white powder-coated metal interior and braked casters support routine access and cleaning. Move and clean the unit only as instructed in the manual.

Included controls

Check conditions without opening the chamber.

External microprocessor control displays current and resettable min/max temperature. A glycol-buffered product probe and separate air sensor support temperature control; the min/max readout is not an interval-recording DDL. Audible/visual high/low temperature and sensor-failure alarms, an adjustable door-open alarm and a battery-powered power-failure alarm support staff response. The power-failure alarm does not provide backup cooling or heating.

Rear volt-free alarm contacts support connection to a separate external alarm system. A pre-installed 1/2-inch probe hole in the right interior wall provides access for user-supplied monitoring equipment. Connected services, external alarms and additional probes are not included simply because connection points are present.

ABOD18 OEM front cabinet
Original front view includes the external controller. A separate OEM control close-up was not supplied.

Included versus optional

Request the whole factory configuration, not a loose accessory price.

Standard features stay included in the base selection. The verified optional codes for this exact model are DL2B, DLPWINC, LHD, DTFAR, KAL.

Factory choices are requests, not automatically compatible combinations or installed-price promises. Use each group’s standard choice to reset a request. Any optional factory selection requires review of the complete unit, installation, configuration, calibration paperwork, price and lead time before ordering. DTFAR requests factory Fahrenheit setup only; the controller already supports both display scales.

Included sensing

Buffered sensing and local controller, not a DDL.

Optional recorded history

DL2B is a factory-installed calibrated USB recording logger. Request the complete configuration.

Optional connected monitoring

DLPWINC is the exact-model wireless option. Confirm connectivity, activation and ongoing service.

Will it fit?

Plan the clearance envelope, not just the cabinet.

The published cabinet dimensions are 78.5 H × 27.5 W × 26 D in.. Depth with the handle is 27.75 inches; depth with the door at 90° is 52 inches and width with the door open is 28 inches. Four pre-installed 3-inch casters have brakes. Use the published height as given rather than adding caster height again.

ABOD18 cabinet dimensions with labelled navy height, green width and orange depth arrows: 78.5 inches high, 27.5 inches wide, 26 inches cabinet depth.
Height: 78.5 in.Width: 27.5 in.Cabinet depth: 26 in.
Tap the diagram to enlarge. Freestanding indoor installation only. Allow at least 5 inches at the top, rear and each side, and keep the front air vent unobstructed. The applicable BOD manual reserves built-in or recessed installation for models with a -BI suffix; ABOD18 is not such a model. Depth with handle: 27.75 inches. Depth with door open 90°: 52 inches. Confirm final setup, packed dimensions and installation clearances separately.

Freestanding indoor installation only. Allow at least 5 inches at the top, rear and each side, and keep the front air vent unobstructed. The applicable BOD manual reserves built-in or recessed installation for models with a -BI suffix; ABOD18 is not such a model.

Install in a protected, well-ventilated indoor area above 60°F (16°C) and below 90°F (32°C); the manual notes optimal ambient conditions of 72 to 78°F (23 to 26°C). Provide a grounded 115 V AC, 60 Hz supply. Do not use an adapter or extension cord.

Review the Specifications tab and manufacturer documents before final placement.

Delivery and receiving

Prepare the route and confirm the final shipment.

Confirm the final packed weight and dimensions for your receiving route. The cabinet itself weighs 270 lb before packing.

FSI lists LTL freight service with supplier overboxing and a custom skid for this model. Checkout retains the original dock-delivery and liftgate options for eligible orders. Multiple-unit or mixed-equipment orders may use freight services. Alaska, Hawaii, US territories and international destinations require a quote.

Keep the packaging and delivery paperwork and inspect the equipment at receipt. Contact Blue Tiger promptly about damage, shortages, incorrect items or order-return review. For manufacturer warranty claims and repair authorization, contact Accucold/FSI directly. Manufacturer documentation lists two years limited parts and labor and five years compressor coverage, subject to written terms, designated service requirements and destination limits. Extended compressor replacement excludes labor. Confirm coverage for your location directly with Accucold/FSI; no worldwide on-site warranty is implied.

Buyer questions

Details that help you decide

Is ABOD18 a vaccine refrigerator?

No. ABOD18 is a refrigerated/heated BOD incubator for environmental water-sample and microbiological applications. Its 4 to 60°C range and 20°C preset are not a vaccine-refrigerator specification.

What is the operating range and factory preset?

The published adjustable range is 4 to 60°C (39.2 to 140°F), with a 20°C factory preset. Verify your protocol and actual loaded conditions independently.

How many incubation bottles will fit?

Accucold states up to 300 300 mL incubation bottles. Actual bottle capacity varies with bottle design and size. Seven wire shelves adjust at 1/2-inch increments; check your real containers and airflow.

Can ABOD18 be built into cabinetry?

Freestanding indoor installation only. Allow at least 5 inches at the top, rear and each side, and keep the front air vent unobstructed. The applicable BOD manual reserves built-in or recessed installation for models with a -BI suffix; ABOD18 is not such a model.

Is a calibrated data logger included?

No calibrated recording DDL is identified as standard. Buffered sensing, current/min/max display and local alarms are standard. DL2B calibrated USB recording or DLPWINC connected environmental monitoring can be requested as factory options.

What connection points are standard?

Rear volt-free alarm contacts and a right-side 1/2-inch probe hole are included. External alarm systems and added monitoring equipment are separate.

Can the door swing be changed?

The base door ships RHD and is user-reversible; factory LHD can also be requested. Confirm reversal constraints with every selected factory option before ordering.

Does the power-failure alarm keep samples at temperature?

No. It is a battery-powered audible warning, not backup refrigeration or heating. Your facility needs its own response and alternate-storage plan.

Why must shipping weight be confirmed?

No final packed weight is confirmed. This listing uses 350 lb for shipping setup; confirm packed dimensions and weight before planning receiving.

Equipment and configuration

Confirm the ABOD18 application and installation plan.

Bring the intended materials, available space, door swing and optional factory monitoring into one reviewed equipment proposal.

    SpecificationDetails
    Nominal Height79.0" (201 cm)
    Height of Cabinet78.5" (199 cm)
    Nominal Width28.0" (71 cm)
    Width27.5" (70 cm)
    Width with Door Open28.0" (71 cm)
    Nominal Depth26.0" (66 cm)
    Depth26.0" (66 cm)
    Depth with Handle27.75" (70 cm)
    Depth with door at 90°52.0" (132 cm)
    Capacity18.0 cu.ft. (510 L)
    Defrost TypeAutomatic
    DoorWhite
    CabinetWhite
    US Electrical SafetyETL
    Canadian Electrical SafetyETL-C
    Amps1.5
    Voltage/Frequency115 V AC/60 Hz
    Weight270.0 lbs. (122 kg)
    Parts & Labor Warranty2 Years
    Compressor Warranty5 Years
    UPC761101150963
    Door SwingRHD
    ReversibleYes
    Shelf TypeWire
    Shelf Qty7
    Adjustable ShelvesYes
    Thermostat TypeDigital
    Fan TypeInterior
    Refrigerant TypeR290
    Refrigerant Amount1.75oz.
    High Side PSI280.0
    Low Side PSI90.0
    Wheel Qty4
    Interior LightYes
    Temperature Range4 to 60ºC (39.2 to 140ºF)
    Interior Height68.5" (174 cm)
    Interior Width24.13" (61 cm)
    Interior Depth18.75" (48 cm)
    Compressor Step Height6.5" (17 cm)
    Compressor Step Width24.13" (61 cm)
    Compressor Step Depth6.5" (17 cm)
    ApplicationBOD incubation, environmental research and microbiology
    Installation and clearanceFreestanding indoor installation only. Allow at least 5 inches at the top, rear and each side, and keep the front air vent unobstructed. The applicable BOD manual reserves built-in or recessed installation for models with a -BI suffix; ABOD18 is not such a model.
    Included monitoringExternal microprocessor control displays current and resettable min/max temperature. A glycol-buffered product probe and separate air sensor support temperature control; the min/max readout is not an interval-recording DDL. Audible/visual high/low temperature and sensor-failure alarms, an adjustable door-open alarm and a battery-powered power-failure alarm support staff response. The power-failure alarm does not provide backup cooling or heating.
    Connection pointsRear volt-free alarm contacts support connection to a separate external alarm system. A pre-installed 1/2-inch probe hole in the right interior wall provides access for user-supplied monitoring equipment. Connected services, external alarms and additional probes are not included simply because connection points are present.
    Factory configurationOnly exact-model options shown in the current manufacturer AVAILABLE UPGRADES table; complete configured quote required.
    Shipping setup weight350 lb used for shipping setup; final packed weight to be confirmed.
    Packed shipping dimensions86 H × 31 W × 31 D in.; supplied public manufacturer export

    Blue Tiger Scientific is a reseller, not the manufacturer. We manage your purchase and order-return requests. Accucold, a division of Felix Storch, Inc. (FSI), handles manufacturer warranty coverage, service and repairs directly.

    Ordering and delivery

    Availability, dispatch timing and freight depend on the selected equipment, configuration and destination. Delivery dates shown on this page are estimates, not guarantees. Supplier processing, lead time and carrier transit can affect arrival. Contact Blue Tiger before ordering if you have a firm deadline or specific receiving requirements.

    For the base equipment, standard dock or liftgate delivery charges to the 48 contiguous United States and Washington, DC are calculated at checkout. Select dock delivery only if a suitable receiving dock and unloading capability are available. Alaska, Hawaii, US territories and international destinations require a quote. Measure the complete access route and prepare the installation site using the manufacturer’s instructions.

    Standard delivery does not include inside placement, stairs or white-glove services. If additional services are needed, Blue Tiger Scientific will review access, elevators, delivery level and placement requirements and provide a separate quote for your approval before any additional service charge is billed.

    Published manufacturer unit weight: 270 lb. The listing uses 350 lb for shipping setup; final packed shipment weight and carton measurements should be confirmed for site planning.

    Inspect your delivery

    Inspect the shipment when it arrives. Keep the original cartons, packing materials and delivery paperwork. Report damage, shortages or an incorrect item to Blue Tiger immediately at info@bluetigerscientific.com, with photographs of the item, packaging, shipping label and delivery receipt.

    For freight arranged by FSI or delivered on FSI trucks, FSI instructs recipients to refuse visibly damaged units and have the driver record and acknowledge the damage on the delivery paperwork. On a multi-unit shipment, refuse the damaged units rather than the undamaged remainder. Concealed damage must be reported within five days after delivery acceptance; contact Blue Tiger immediately so the manufacturer’s reporting deadline can be met.

    For customer-nominated, collect or third-party-carrier shipments, claims must be pursued with that carrier. Do not assume FSI will accept a freight-damage return. Contact Blue Tiger for the order information and instructions before arranging any return shipment.

    Order returns must start with Blue Tiger

    All order-return requests must be initiated through Blue Tiger Scientific at info@bluetigerscientific.com. Accucold/FSI does not provide an automatic buyer’s-remorse return right. Eligibility and written authorization must be confirmed before anything is shipped.

    • Contact Blue Tiger within 14 days of delivery to request review, subject to the product-specific manufacturer restrictions. FSI does not accept an eligible factory-sealed return after 30 days from its original shipment date, so request review promptly enough for an authorized return to meet that deadline.
    • Include your Blue Tiger order number, exact manufacturer part number, serial number if applicable, quantity, contact details and reason for the request. Provide the photographs required for the manufacturer’s review.
    • Wait for written return authorization and the designated return address. Do not send an order return to Blue Tiger’s business address or directly to FSI without these instructions.
    • For an eligible non-defective stock return, FSI requires the original unopened carton and an undamaged appliance in new condition. Opened packages are not accepted under that return route.
    • FSI applies a 25% restocking charge per eligible returned item and may charge a higher percentage on larger orders. Your authorization will state the applicable charges. Original outbound freight, including embedded freight on a shipment, reduces the return credit.
    • The customer is responsible for approved non-defective return freight and insurance. Use the authorized carrier and instructions supplied for this heavy equipment. Damage, incorrect-item and defect reports are reviewed separately from an unwanted-product request.

    Customized and factory-upgraded equipment

    FSI excludes made-to-order models with customizations from ordinary returns. Its listed exclusions include factory-installed thermometers, alarms, data loggers and digital-thermostat upgrades, as well as specified lock, door and cabinet customizations. Do not assume a factory-upgraded configuration is returnable. Confirm the exact model’s eligibility before ordering.

    Manufacturer warranty and service go directly to Accucold

    Manufacturer documentation lists two years limited parts and labor and five years compressor coverage, subject to written terms, designated service requirements and destination limits. Extended compressor replacement excludes labor. Confirm coverage for your location directly with Accucold/FSI; no worldwide on-site warranty is implied.

    Contact Accucold/FSI directly for warranty coverage questions, claims, service assignment and repair authorization: service@accucold.com or 718-893-3900. Technical questions can be directed to techsupport@accucold.com. Have your model, serial number, proof of purchase, delivery location and a description of the problem ready.

    Blue Tiger Scientific does not administer manufacturer warranty claims, authorize warranty repairs or provide warranty service. Do not commission an independent repair or send equipment for service until FSI provides authorization and instructions. Service not assigned or authorized by FSI may not be covered.

    Manufacturer coverage depends on proper installation, operation and maintenance. The written warranty includes exclusions for matters such as misuse, improper installation, unauthorized modifications and consequential losses, including product spoilage. Equipment warranty coverage is not a guarantee of stored-material value or reimbursement.

    International destinations and service areas

    International customers should request a quote to confirm the equipment configuration, destination eligibility and shipping arrangements. Confirm responsibility for any import duties, taxes and brokerage in the quote. International returns are not permitted under Blue Tiger Scientific’s published return policy.

    Warranty coverage and service arrangements vary by model and destination. Contact Accucold/FSI directly before purchase to confirm service for your exact delivery location. Do not assume worldwide on-site service is included.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Your Carts

Which would you like to open?

Shopping Cart

0 items

Review items for online purchase.

View Cart

Quote Cart

0 items

Review items and request a quote.

View Quote Cart

Your two carts stay separate. Nothing is moved or combined.