Skip to content
SmartReader MultiMode Plate Reader, 115V
SmartReader MultiMode Plate Reader, 115V
SmartReader MultiMode Plate Reader, 115V
SmartReader MultiMode Plate Reader, 115V
SmartReader MultiMode Plate Reader, 115V
SmartReader MultiMode Plate Reader, 115V
SmartReader MultiMode Plate Reader, 115V
SmartReader MultiMode Plate Reader, 115V

SmartReader MultiMode Plate Reader, 115V

$24,482.40

    Experience the future of microplate reading with the Accuris SmartReader™ Multimode. This versatile instrument offers unparalleled performance and flexibility for a wide range of applications, including absorbance, fluorescence, and luminescence assays. Its user-friendly interface, advanced optics, and robust features make it the ideal choice for researchers and scientists seeking accurate, efficient, and reliable results.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

The SmartReader™ Multimode from Accuris is a cutting-edge microplate reader designed to cater to the advanced requirements of modern life science laboratories. Equipped with comprehensive high-performance optical systems, it serves as an all-in-one solution for absorbance, fluorescence, and luminescence applications.

This versatile instrument can rapidly process assays in standard 96-well plates and also accommodate 6, 12, 24, 48, and 384 well plates. Programming and operation are managed via its large color touch screen, eliminating the need for an external computer or software. Optional PC software is available for streamlined control and data management on a Windows™ PC. The user-friendly interface guides operators through various options for assay setup and processing. The device includes a built-in plate shaker with linear, orbital, and double-orbital modes, and an incubator capable of top heating from ambient +4°C to 45°C to prevent condensation when lids are used on microplates. Upon startup, the SmartReader Multimode performs a self-diagnostic test and automatic calibration, ensuring consistent results across diverse assays.

UV-Visible Absorbance

The SmartReader Multimode utilizes an advanced monochromator and a long-life, broad-spectrum xenon flash lamp to produce incident light at user-selected wavelengths from 200 to 1000 nm in 1 nm steps. Assays are processed quickly, with a full 96-well plate being read in under 15 seconds. The kinetic assay feature allows for multiple readings over a set period, displaying real-time curves for each well. The optional SmartDrop™ plate facilitates fast and convenient UV absorbance evaluation of up to 16 nucleic acid and protein sample droplets.

Absorbance Applications:

  • ELISA Assays
  • Colorimetric Assays (Bradford, Lowry, etc.)
  • Enzyme Kinetics
  • Spectral Scanning
  • DNA & RNA Analysis
  • And more

Fluorescence

The device includes three filter modules providing common excitation and emission wavelengths for fluorescence assays, with additional modules available. These advanced modules incorporate dichroic mirrors with narrow band-pass optical filters, ensuring high light transmission and increased detection sensitivity. Modules are easily exchangeable and barcoded for automatic wavelength data loading. The SmartReader Multimode features automatic dynamic range selection, allowing the photomultiplier tube to accurately capture and normalize signal intensity.

Luminescence

Capable of luminescent detection, the SmartReader Multimode can handle both flash and glow assays. An advanced photomultiplier tube (PMT) enhances the sensitivity of weak signals, prevents over-saturation of strong signals, and provides an ideal detection range for all common luminescence applications. Up to two sample injectors (available separately) can be installed, compatible with both 96 and 384-well plates.

Data Transfer & PC Software

Data from the SmartReader Multimode can be exported as .XLS or .CSV files via the included USB flash drive, the FTP server, or using the optional SmartReader™ PC Software. The software allows for remote programming and operation via a cable connection, automatically uploading data from the instrument to a connected PC for further analysis. Versions are available for academic research and FDA 21 CFR Part 11 compliance.

Features:

  • Intuitive, 10-inch color touch screen
  • Stand-alone system with optional PC software (FDA CFR Part 11)
  • Monochromator-based system for UV through visible absorbance
  • Filter module system for fluorescence assays
  • Advanced PMT detector for luminescence assays
  • Optional automatic injection modules for flash luminescence
    General Specifications
    Feature Details
    Model Accuris SmartReader™ Multimode
    Measurement Technologies Absorbance, Fluorescence, Luminescence
    Plate Formats 6- to 384-well plates
    Shaking Linear (4.7 Hz, 7.0 Hz, 13.5 Hz), orbital and double orbital (240 – 1200 rpm)
    Incubation Range RT +4 °C to 45 °C
    Display 10.0 inch touchscreen
    Communication Ports 2 USB A type ports / 1 USB B type port
    1 Ethernet port
    RS232 interface
    Dimensions (WxDxH) 16.5 x 21.7 x 15.2 in.
    (42.0 x 55.0 x 38.6 cm)
    Power Input AC 100 to 240 V, 50 to 60 Hz
    Weight 33 kg / 72.8 lbs
    Absorbance
    Feature Details
    Light Source High Energy Xenon Flash Lamp
    Detector Photodiode
    Wavelength Accuracy 2 nm
    Wavelength Repeatability 0.2 nm
    Bandwidth (FWHM) > 2.5 nm
    Wavelength Range 200 – 1000 nm, 1nm steps
    Absorbance 0.0 – 4.0 OD
    Resolution 0.0001 OD
    Accuracy 96-precision mode:± (1.0 %+0.003Abs)@ (0.0-2.0Abs] ;± 2.0 % @ (2.0-3.0Abs]
    Repeatability CV < 1.0 % or SD< 0.003 Fast(0.0-3.0Abs]CV < 0.5 % or SD< 0.003 Accurate(0.0-3.0Abs]
    Stray Light 0.1 % @ 220 nm
    Linearity R2 > 0.999 @ [0.0-3.0Abs]
    Measurement Speed < 15 seconds
    Fluorescence
    Feature Details
    Reading Mode Top Reading
    Excitation Light Source High Energy Xenon Flash Lamp
    Detector Photo Multiplier Tube (PMT)
    Detection Limit ≤ 1 pM
    Wavelength Range EX: 200 – 1000 nm; EM: 270 – 850 nm
    Included Filter Cartridges (EX / EM): 470 / 525nm ; 523 / 564nm ; 624 / 692nm
    Linear Dynamic Range 6 logs
    Luminescence
    Feature Details
    Detector Photo Multiplier Tube (PMT)
    Detection Limit 15 amol / well
    Linear Dynamic Range 6 logs

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY