    SKU: MC125US

    UPC: 810666004256

    MPN: MC125US

    Range: Range: 0.00 to 14.00 pH | ORP: ±1000 mV

    Resolution: 0.1 pH, 1 mV

    Accuracy: ±0.2 pH | ±5 mV

    Calibration: Manual 2 point pH only | ORP Factory Calibrated

    Manual: Milwaukee MC125 Manual

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Description

The Milwaukee MC125 PRO pH and ORP controller is designed for people looking to measure and adjust pH and ORP levels automatically with one simple controller. Just set your pH and ORP parameters and let the Milwaukee pH Controller do the rest.

The MC125 is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks, aquariums, pools, and spas.

Features:

Accuracy

The Milwaukee PRO 2 in 1 controller offers an accuracy to ±0.2 pH with two point manual calibration and ORP accuracy to ±5 mV.

Real-time monitoring

See real-time pH and ORP measurements from 0.00 pH to 14.00 pH and -1000 mV to 1000 mV with a large LED with easy switching between parameters.

Automation for constant measurement

The controller provides a control range of 4 to 8 pH and -200 to 600 mV. Just set your control range and the controller do the rest.

Two dedicated relays for pH and ORP control to support a range of compatible devices

Choose your device including oxygen pumps, CO2-regulators, O3 ozonizers and other pH & ORP control devices by simply plugging the device into the correct pH or ORP outlet.

Easy installation

The controller comes with a complete mounting kit including two probe holders.

Design features

  • Fast easy to read current results with large digital LCD readout
  • Accurate to ±0.2 pH and ±5 mV
  • Simple two-point calibration for increased accuracy with manual trimmers for easy adjustment
  • 4 to 8 pH and -200 to 600 mV alarm set point range is easily accessible on the front panel
  • Alarm activated when reading is above or below set point
  • Comes with full mounting kit including probe holders
  • Lab grade, double junction, gel filled pH probe and platinum ORP electrode designed for low maintenance
  • 6.5’ probe cables for extra flexibility
  • 12 VDC power supply
  • Small footprint of 5.9 x 3.2 x 1.35”
  • Lightweight monitor at approx 7 oz.

What People Are Saying

"I run this unit 24/7 and have not had any problems. It keeps my fish tank CO2 injector running perfectly and puts my mind at ease regarding overdosing."

Care and Use

Properly maintaining your pH and ORP probes will give you fast, accurate results for longer. pH and ORP probes are similar in design but there are some differences.

pH probes have a sensing bulb that loses sensitivity with age. All pH sensors have a limited life and response time gets longer with age.

ORP probe have usually a platinum electrode instead of a glass bulb. This electrode has a longer life but can have a residue build up that affect response rates and accuracy.

Both electrodes have a reference junction that can become clogged resulting in slow and inaccurate results. Cleaning and keeping the probe hydrated will help prevent this.

pH Probe

Here are our top four tips for your pH probe.

1. Always store with the cap full of MA9015 Storage Solution not distilled or deionized or reverse osmosis water.

2. Clean your Probe regularly by soaking in MA9016 Cleaning Solution for about 20 minutes.

3. Calibrate the (pH ONLY) after cleaning and/or storage before testing to adjust for changes in the pH sensor.

4. Gently stir the Probe in the sample for a faster result.

ORP Probe

Here are our top three tips for your ORP probe.

1. Always store with the cap full MA9015 storage Solution not distilled or reverse osmosis water.

2. Clean your probe regularly by soaking in MA9016 Cleaning Solution.

3. After cleaning return the ORP sensor to the tank.

Thank you for considering Milwaukee to help you take your results to the next level.

    Specification Detail
    pH Range: 0.00 - 14.00 pH
    ORP Range: ± 1000mV
    pH Resolution: 0.01 pH
    ORP Resolution: ± 1 mV
    pH Accuracy: ± 0.2 pH
    ORP Accuracy: ± 5 mV
    Set point pH: 4 to 8 pH
    Set point ORP: -200 to 600 mV
    Calibration: Manual 2 points pH | OPR Factory calibrated
    Alarm Active when reading is higher or lower than set point
    pH Dosing Contact
    1 power plug for CO2 dosing
    ORP Dosing Contact
    1 power plug for O3 dosing
    pH Electrode: MA911B/2 (included)
    ORP Electrode: MA921B/2 (included)
    Environment: 0 to 50 °C / 32 to 122 °F; max RH 95%
    Power Supply: 12 VDC adapter (included)
    Power Drivers: 115 VAC, 2A, 60Hz or 230 VAC, 1A, 50Hz
    Dimensions: 5.8 x 3.25 x 1.26 inches
    Weight: 7.1 ounces

    Milwaukee Instruments Warranty & Returns Policy
    (For Milwaukee Instruments ONLY – Not for Milwaukee Tools)

    How to Initiate a Return or Warranty Claim
    For products purchased through Blue Tiger Scientific, all returns must be initiated directly with us. However, all warranty claims must be handled directly through Milwaukee Instruments.

    Warranty Information
    Milwaukee Instruments products are manufactured to meet the highest quality standards and come with a limited warranty against defects in materials and workmanship. Products may be returned for repair or replacement at Milwaukee's discretion. Warranty is void if the product has been abused, misused, or repaired by unauthorized persons.

    To register your Milwaukee product, click here.

    Warranty Periods

    • Handheld testers, portable meters, and stationary monitors/controllers: 2 years
    • Bench meters: 3 years
    • PH600 pH Pen and similar versions: 1 year
    • Replaceable probes: 6 months

    Warranty begins on the original end-user purchase date or a maximum of 12 months from dealer purchase. Valid only with proper usage and maintenance. Service occurs at Milwaukee Instruments' North Carolina Technical Service Center.

    Note: Meters used in Kangen Water or “Negative ORP Water” applications are excluded from warranty coverage. Any warranty for these uses is null and void.

    Filing a Warranty Claim
    Contact Milwaukee Instruments Customer Service at (252) 443-3630 EST for an RMA number. Mark the RMA clearly on the box and ship prepaid. Improper packing can void the warranty.

    Return Policy (Blue Tiger Scientific)
    All purchases are final, but returns may be accepted under specific conditions:

    • Items must be in new condition with original packaging and contents.
    • Returns must be initiated within 14 days of purchase.
    • Subject to up to 30% restocking fee.
    • Customer pays all return shipping.
    • Initial shipping charges are non-refundable.

    Returns will be refused if packaging is damaged or contents are missing.

    Initiating a Return with Blue Tiger Scientific
    Contact Blue Tiger Scientific for an RMA and shipping instructions. Mark RMA clearly and pack securely to avoid transit damage. Shipping damage claims are the sender’s responsibility.

    Refunds, if eligible, will be processed within 5–10 business days. Credit card refunds may take longer to appear on your statement.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY