    Control the liquid, not just the hotplate. This 120 V ceramic hotplate stirrer includes the PT 1000.60 sensor for direct medium-temperature control.

    • Up to 10 L water; 100–1500 rpm stirring
    • 180 × 180 mm ceramic plate; 50–500 °C plate heating
    • Includes sensor and IKAFLON 20, 30 and 40 stirring bars

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

IKA • C-MAG HS 7 DIGITAL • 0003487001 • 120 V

Heat the plate. Control the liquid. Know the difference.

Bring controlled heating and magnetic mixing to routine research preparation. The IKA C-MAG HS 7 digital pairs a chemically resistant ceramic surface with an included PT 1000.60 sensor, so you can regulate temperature in the liquid rather than relying on the hotplate setting alone.

For one vessel at a time, with stirring capacity up to 10 L of water. This US configuration includes three IKAFLON stirring bars, making the instrument, sensor and starter bar selection a single clearly defined purchase.

IKA C-MAG HS 7 digital ceramic hotplate stirrer with LCD temperature display and separate temperature and speed controls
Manufacturer photograph of the instrument. Included sensor and stirring bars are listed below, but are not shown.
10 LMaximum stirring volume, water
50–500 °CHeating plate range
100–1,500 rpmStirring speed range
180 × 180 mmCeramic plate

What arrives with catalog 0003487001?

  • 1 × IKA C-MAG HS 7 digital, 120 V / 50–60 Hz
  • 1 × PT 1000.60 stainless-steel temperature sensor
  • 1 × IKAFLON 20 magnetic stirring bar
  • 1 × IKAFLON 30 magnetic stirring bar
  • 1 × IKAFLON 40 magnetic stirring bar

Vessels, a sensor-support stand and clamp, and other accessories are not listed in IKA’s standard delivery scope. Arrange secure sensor positioning appropriate to your vessel. MINISTAR and MICROSTAR overhead stirrers are separate instruments, not included parts or verified add-on accessories for this hotplate.

Choose it for the job, not just the maximum temperature

Routine heated preparation

A practical fit for research buffer and reagent preparation when your liquid, vessel and process are suitable for magnetic stirring and hotplate heating.

Temperature-sensitive workflows

Use the supplied PT 1000.60 to control the liquid temperature. IKA specifies ±0.5 K control accuracy in the medium with PT1000; actual results still depend on a suitable, well-mixed setup.

Low-viscosity mixing

The 10 L rating is based on water. Viscosity, vessel geometry and stir-bar coupling determine usable capacity. For difficult, viscous loads, evaluate a separately configured overhead stirrer instead.

Plate temperature is not sample temperature

A hotplate transfers heat through the vessel before it reaches the liquid. Reading the plate temperature does not tell you the temperature of the whole sample. The sensor changes where the instrument measures and controls.

WITHOUT THE SENSOR

In mode B or C, heating without PT1000 uses the plate temperature target. The liquid may be cooler and may respond more slowly. Do not treat a plate setpoint as a verified sample temperature.

WITH THE INCLUDED SENSOR

PT 1000.60 measures in the liquid. The target is the desired medium temperature, and the actual-temperature display reports the sensor reading. Keep the sensor at least 20 mm immersed, securely held and clear of the stirring bar.

Read the numbers correctly. The medium’s actual-temperature display resolves 0.1 K. That is different from the specified ±0.5 K control accuracy. Temperature setpoint increments are 1 K. Stirring speed is adjusted with the 0–6 scale; this model does not provide a numeric RPM display.

Will it fit your bench?

BODY WIDTH 215 mm
CERAMIC PLATE
180 × 180 mm
Body depth 330 mm
Overall height 105 mm
Simplified footprint guide. Not a vessel-size or clearance drawing.

Allow room beyond the 215 × 330 mm body for safe access, cables, sensor support and the vessel. The manual calls for at least 100 mm from walls and adjacent equipment and 800 mm of free space above the instrument.

The current IKA product data specifies a 180 × 180 mm ceramic plate and a 15 kg maximum load. Load and mixing volume are separate limits: neither is a guarantee that every vessel or viscous sample will work.

Use a level, dry, fire-resistant, non-slip work surface and a grounded supply matching the 120 V nameplate. The instrument is rated IP21, not for immersion or washdown.

A repeatable setup, from first mix to cool-down

1 • Prepare safely

Read the manual and assess the chemicals and vessel. With the device off and unplugged for accessory installation, secure the sensor support. Connect the PT1000 with power off. Place the stir bar in a suitable vessel and keep the probe at least 20 mm immersed.

2 • Build stable circulation

Start with the speed control at its left stop. Increase gradually to create stable circulation, not splashing or vessel movement. Use the supplied bar that couples reliably in your vessel; maximum supported bar length is 80 mm.

3 • Set the liquid target

Select the appropriate operating mode, confirm the sensor reading, then set heat. Factory mode A requires PT1000 for heating. Let the mixed sample equilibrate before recording results.

4 • Shut down and cool

Switch heating off and allow the plate and vessel to cool. HOT indicates a plate above 50 °C while the unit remains powered in stirring or standby. A dark display after unplugging is not evidence that the surface is cool.

Choose the restart behavior deliberately

The three operating modes change what happens after power is removed. Choose the mode as part of your laboratory procedure, not as a substitute for supervision.

  • Mode A, the factory setting: heating requires PT1000; the temperature target resets to 0 °C and heating is off at power-on. A configurable HI TEMP value limits the adjustable target.
  • Mode B: settings are retained after switch-off or a power interruption, with automatic restart behavior. Heating without the sensor is possible.
  • Mode C: retains the mode B behavior and locks settings against adjustment. Return to A or B to change settings.

The independent safety circuit is fixed at 550 °C. It is not an adjustable solvent-specific cutoff. The family safety flyer also describes features of other IKA stirrers; do not assume every family-level feature applies to this model.

For trained laboratory use only. Do not use in explosive atmospheres. Evaluate flammable liquids and ignition risks using your lab’s risk assessment and the manual. The surface, sensor and vessel can all remain hot after heating stops.

If the result is not what you expected

The bar loses coupling

Reduce speed and check vessel centering, bar selection and viscosity. Increasing speed can make decoupling worse. E11 indicates a blocked motor; the manual directs a bar change or lower viscosity.

The displayed temperature seems wrong

Confirm whether the display is reading the plate or PT1000. Check immersion and stable mixing. E5 concerns the sensor not being in the medium; do not treat this error as a comprehensive boil-dry guarantee.

An error stops the run

Switch off and correct the stated cause before restarting. E1 concerns a missing sensor in mode A, E3 internal overheating and E6 a defective sensor. Stop use and seek service if a fault persists.

Complete the preparation workflow

Related workflow: Heathrow borosilicate Erlenmeyer flasks offer a separate vessel-selection route. Check the selected flask’s dimensions, temperature limits and method suitability; this link is not a blanket fit or heating-compatibility claim.

Related workflow: Heathrow 90-position wire lab drying rack supports the wash-and-dry stage after preparation. It is separate bench equipment, not a hotplate accessory.

Frequently Asked Questions

What is included with IKA C-MAG HS 7 digital 0003487001?

The 120 V instrument, one PT 1000.60 stainless-steel sensor and one each of the IKAFLON 20, 30 and 40 stirring bars. Vessels and sensor-support hardware are not listed in the standard scope.

Is 0003487001 the US voltage version?

Yes. IKA’s current US technical data identifies 0003487001 as 120 V, 50/60 Hz, with 1020 W power input. Do not confuse it with other regional versions or assume universal voltage.

Does the 500 °C rating mean my sample reaches 500 °C?

No. The current plate heating range is 50–500 °C. The liquid temperature depends on the sample, vessel and heat transfer. With the supplied PT 1000.60 immersed, the device controls to the measured medium temperature rather than substituting plate temperature for sample temperature.

Does digital mean the instrument displays RPM?

No. Temperature is displayed digitally, but speed is adjusted using a 0–6 scale across a specified 100–1500 rpm range. Do not choose this model expecting a numeric RPM readout.

Can it stir 10 L of a viscous liquid?

The 10 L maximum is specified for water. Usable capacity for more viscous liquids depends on the sample and vessel, not volume alone. A separately selected overhead-stirring system may be more suitable; IKA’s MINISTAR and MICROSTAR recommendations do not establish accessory compatibility.

What happens after a power interruption?

That depends on the mode. In factory mode A the heat target resets to 0 °C and heating is off at power-on. Modes B and C retain settings and have automatic restart behavior. Review the manual before selecting either retained-settings mode.

How do I know when the plate is safe to touch?

HOT appears when the plate is above 50 °C while powered in stirring or standby. Do not rely on this warning after unplugging or loss of power. Allow the plate, sensor and vessel to cool before handling.

Is this a clinical device, and is supplier stock confirmed?

This listing is for research laboratory use, not diagnostic or medical use. Supplier availability and dispatch timing must be confirmed for the destination. IKA’s public page requires login to see availability; neither a listed price nor the 5 kg instrument weight establishes stock, freight or packed shipping weight.

    Product Specifications

    ParameterDetails
    BrandIKA
    ModelC-MAG HS 7 digital
    Manufacturer catalog number0003487001
    Voltage / frequency120 V / 50–60 Hz
    Number of stirring positions1
    Maximum stirring quantity10 L per position (H₂O)
    Maximum load15 kg
    Speed range100–1500 rpm
    Speed adjustment / display0–6 scale; no numeric RPM display
    Direction of rotationLeft
    Motor output rating1.5 W
    Maximum stirring-bar length80 mm
    Heating plate range50–500 °C
    Heating output1000 W
    Total power input1020 W
    Set / actual temperature displayLCD / LCD
    Plate temperature setting resolution1 K
    Medium temperature setting resolution1 K
    Medium actual-temperature display resolution0.1 K with PT1000
    Medium control accuracy±0.5 K with PT1000
    External sensor connectionPT1000
    Included sensorPT 1000.60, stainless steel
    Safety circuitFixed at 550 °C
    Plate material / sizeCeramic / 180 × 180 mm
    Instrument dimensions (W × H × D)215 × 105 × 330 mm
    Instrument weight5 kg; not packed shipping weight
    Heating rate5 K/min (1 L H₂O in H1500, IKA test condition)
    Plate self-heating+2 K at maximum stirring; 22 °C room temperature, 1 hour
    Permissible ambient temperature5–40 °C
    Permissible relative humidity80%
    Protection ratingIP21 (DIN EN 60529)
    UseResearch laboratory use only

    Ordering Information

    ParameterDetails
    Cat. no.0003487001
    Store SKUBTS-0003487001
    Order unit1 instrument package
    IncludedC-MAG HS 7 digital; PT 1000.60; IKAFLON 20, 30 and 40
    Electrical configuration120 V, 50–60 Hz
    Packed shipping weightConfirm before shipment

    Authorized reseller

    Blue Tiger Scientific is an authorized reseller of IKA products. We handle your purchase and requests to return an order. IKA is the manufacturer and provides manufacturer warranty coverage, technical service, calibration and repairs. Blue Tiger Scientific does not perform these services or determine warranty coverage.

    Shipping and delivery

    Availability, dispatch timing and freight depend on the product and destination. Delivery dates are estimates unless expressly confirmed as binding in writing by IKA. Contact Blue Tiger Scientific for order-specific shipping information.

    Inspect your delivery

    Inspect the equipment and packaging immediately upon receipt. Report damage, missing items or visible defects to Blue Tiger Scientific immediately, retaining photographs, packaging and shipping documents. IKA's terms require written notice of visible defects, shortages or quality deviations no later than seven days after receipt, and notice of hidden defects no later than seven days after discovery. Prompt reporting allows us to forward the information to IKA within its deadlines. Do not use or install equipment found to be defective until instructions are provided.

    Returns must start with Blue Tiger Scientific

    Contact Blue Tiger Scientific before returning any IKA product. Returns are not automatic and require IKA's written approval and an RMA number. We will provide the approved destination and return instructions; do not ship equipment to Blue Tiger or IKA without those instructions.

    IKA's published return conditions require a written return request within 60 days of shipment, and the returned goods must reach IKA within 30 days after the RMA is issued. These are manufacturer approval requirements, not an unconditional 60-day return guarantee.

    Approved returns must be in excellent, resalable condition in the original container. IKA requires its RMA and original invoice information with the return; Blue Tiger will coordinate the required order documentation. Returns not caused by an IKA error are subject to a minimum 15% restocking charge. Inspection may identify additional service or repair charges needed to restore resalable condition. Return freight is normally prepaid by the purchaser. Charges and any applicable cross-border brokerage responsibility will be confirmed with the authorization. IKA states that returns due to its own error receive full credit. Any customer refund is confirmed through Blue Tiger after the return is accepted and the applicable credit is established. Unauthorized returns may be refused and may receive no credit.

    Manufacturer warranty and service

    IKA handles warranty registration, warranty assessment, technical support, repair and calibration directly. Blue Tiger Scientific does not administer or perform manufacturer warranty service. Keep your proof of purchase and serial number, and register the product with IKA within 90 days of purchase to meet its published registration requirements.

    Warranty periods and free extensions depend on the exact product and IKA's applicable terms. No single warranty period or lifetime-warranty claim applies to all IKA products. IKA determines coverage and the applicable remedy, subject to its conditions and exclusions. For any physical return, including equipment requiring manufacturer service, contact Blue Tiger first so the required authorization and routing are confirmed; IKA handles the technical service itself.

    Cleaning before a service shipment

    Equipment sent to IKA for repair must be cleaned, safely decontaminated as applicable, and accompanied by IKA's completed and signed decontamination certificate. IKA states that it cannot process a repair without this document. Follow the specific authorization and packing instructions before dispatch.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat