Skip to content
Hanna Instruments HI93703 Portable ISO Turbidity Meter – ISO 7027 Compliant with Optional Maintenance Kit
Hanna Instruments HI93703 Portable ISO Turbidity Meter – ISO 7027 Compliant with Optional Maintenance Kit
Hanna Instruments HI93703 Portable ISO Turbidity Meter – ISO 7027 Compliant with Optional Maintenance Kit
Hanna Instruments HI93703 Portable ISO Turbidity Meter – ISO 7027 Compliant with Optional Maintenance Kit
Hanna Instruments HI93703 Portable ISO Turbidity Meter – ISO 7027 Compliant with Optional Maintenance Kit
Hanna Instruments HI93703 Portable ISO Turbidity Meter – ISO 7027 Compliant with Optional Maintenance Kit

Hanna Instruments HI93703 Portable ISO Turbidity Meter – ISO 7027 Compliant with Optional Maintenance Kit

$1,144.99

    The HI93703 is a high accuracy benchtop turbidity meter designed for measuring the turbidity of water and wastewater with precision in both field and laboratory settings. It meets and exceeds ISO 7027 requirements for turbidimetric measurements. For added value, the HI93703C kit includes AMCO-AEPA-1 primary turbidity standards for calibration and performance verification.

    Up to three-point calibration

    Positive-locking cuvette system

    Water-resistant keypad

    *Products classified as Dangerous Goods can only be shipped via ground.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

HI93703 Turbidity Measurement Principle

Understanding Turbidity Measurement with the HI93703

The HI93703 **portable turbidity meter** operates by analyzing how a light beam interacts with a water sample. As light passes through, suspended particles cause it to scatter in multiple directions. The degree and pattern of this **light scattering** are influenced by factors such as the wavelength of the incident light, the physical characteristics of the particles (size and shape), their refractive index, and the sample's inherent color. The **turbidity analyzer's** optical system strategically employs an infrared LED as a stable light source and a dedicated **scattered light detector** positioned at a 90° angle to precisely measure the intensity of the scattered light.

A critical factor in achieving accurate **low-range turbidity measurements** is minimizing stray light – light detected by the sensor that isn't a result of particle scattering. The advanced optical architecture of the HI93703 is engineered for exceptionally low stray light, ensuring highly reliable and precise results, especially for water samples with minimal **turbidity levels**.


The HI93703C Portable Turbidity Meter Kit: Everything You Need

  • HI93703 **Portable Turbidity Meter** for accurate **water testing**
  • Two high-quality **sample cuvettes** for reliable measurements
  • Protective **cuvette caps** to prevent contamination
  • Four long-lasting 1.5V AA **batteries** for portable operation
  • Comprehensive **instruction manual** for easy setup and use
  • **HI93703-0 (0 FTU) calibration standard** for accurate calibration
  • **HI93703-10 (10 FTU) calibration standard** for reliable calibration
  • Lint-free **cuvette wiping tissue** to ensure optical clarity
  • Durable **carrying case** for safe transport and storage of the **turbidity meter kit**
HI93703C Portable Turbidity Meter Kit Contents

    Specification Detail
    skuHI93703-web
    FTU Range0.00 to 50.00 FTU *
    50 to 1000 FTU *
    FTU Resolution0.01 and 1 FTU *
    FTU Accuracy±0.5 FTU* or
    ±5% of reading (whichever is greater)
    Typical EMC Deviation±2% FS
    Turbidity Light DetectorSilicon Photocell
    Calibration3 point (0,
    10 and 500 FTU*)
    Light SourceInfrared LED
    Lamp LifeLife of the instrument
    Environment0 to 50° C (32 to 122° F),
    RH max 95% non-condensing
    Power Supply4 x 1.5V AA alkaline
    Battery LifeApprox. 60 hours of use or 900 measurements
    Auto Shut-OffAfter 5 minutes of non-use
    Dimensions220 x 82 x 66 mM (8.7 x 3.2 x 2.6in.)
    Weight510 g (1.1 lb.)
    Warranty2 years

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    Portable Turbidity Meter Instruction Manual
    Download
    Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY
Expanded View

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)