Skip to content
Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator Titrator Hanna Instruments
Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator Titrator Hanna Instruments
Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator Titrator Hanna Instruments
Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator Titrator Hanna Instruments
Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator Titrator Hanna Instruments
Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator Titrator Hanna Instruments
Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator Titrator Hanna Instruments
Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator Titrator Hanna Instruments
Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator Titrator Hanna Instruments
Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator Titrator Hanna Instruments

Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator

$25,000.00

    The HI933‑01 Karl Fischer Volumetric Titrator delivers precise, automated moisture analysis for laboratories and industrial environments that demand accuracy and efficiency. Designed to measure water content from 100 ppm to 100%, this compact, chemical‑resistant titrator provides fast, reliable results at the push of a button—helping users meet strict quality standards while reducing hands‑on time and reagent exposure.

    High‑precision automated moisture determination from 100 ppm to 100%

    Durable, compact design engineered to withstand harsh solvents and save bench space

    Safer, more efficient workflow with reduced reagent handling and streamlined operation

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

GET A QUOTE

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b
Accuracy capabilities +
  • Equipped with a dosing pump that offers an unmatched 40,000 step accuracy
  • Save and store up to 100 titration methods (either user-defined or standard). Customize methods to fit specific application needs or testing requirements. Easily program this titrator with standard methods that are in accordance with affiliations like ISO, ASTM, AOAC, AOCS, EPA and more
  • Operators can program this titrator unit with notification reminders for when to standardize the titrant
  • This titrator automatically calculates the average titer value and users can update the nominal concentration in the sample methods with the press of a button
  • Track progress in real-time. All important information is shown on the titrator's large LCD screen. Use the live titration curve during analysis to quickly recognize patterns and spot potential problems
  • Achieve high speed analysis without sacrificing accuracy with dynamic titrant dosing. This occurs by adjusting the volume of titrant dosed according to the mV response from the titrator reaction
  • Get more accurate measurements with automatic drift rate compensation. This corrects the titration calculation to account for the effects of any moisture that may enter the cell
  • Choose the endpoint termination criteria based on mV stability times or drift rates with the dual platinum pin electrode
  • Maintain data quality with the titration results averaging feature. Ideal for those operators who consistently run replicates of samples. The successive results from a titration method are averaged along with the standard deviation
  • Attain a reliable starting baseline with the multistage analysis. This works well for users that test multiple sample types with different methods for each
Durability and design details +
  • Manufactured to stand up to the harsh solvents and reagents used during titrations
  • Made with tough, chemically resistant materials including a strong casing as well as PTFE tubing with glass and stainless-steel components
  • Convenient-size, fits perfectly into any lab space
  • Simple to set up and user-friendly. Perfect for labs and businesses that have multiple personnel shift changes throughout the day
  • Intuitive screens and menus help operators navigate this titrator unit easily without getting lost in a nest of information
Safe and important operation features +
  • Introducing a solid or liquid sample to the titration vessel is simple and straightforward. Includes a quick-remove sample port with a replaceable rubber septum
  • Equipped with a sealed solvent management system and built-in air pumps. Users can move the reagent into waste and refill without physically touching the reagent. This makes testing seamless, eliminates manual chemical handling, and reduces the risk of contact or spills. The sealed solvent management system also mitigates excess moisture from getting into the cell
  • Standby mode keeps the solvent dry between titrations or when the titrator is not in use
  • Includes a rechargeable, color-indicating, silica gel desiccant. The desiccant changes color to alert users when its absorption capacity is depleted and needs to be recharged or replaced

Resources

What's Included +
Item Quantity / Notes
Karl Fischer Volumetric Titrator HI933 (1 pc)
Karl Fischer dual platinum pin electrode HI76320 (1 pc)
Dosing pump assembly HI930100 (1 pc)
Burette assembly HI930505 (1 pc)
Air pump and magnetic stirrer assembly HI930180 (1 pc)
Beaker assembly HI930520 (1 pc)
Beaker support (1 pc)
Pump locking screws with plastic head (2 pcs)
Titrant bottle assembly HI900530 (1 pc)
Solvent bottle assembly HI900531
Waste bottle assembly HI900531 (1 pc)
Calibration key HI900941 (1 pc)
Power supply HI900946 (1 pc)
USB cable HI920013 (1 pc)
USB flash drive HI930900U (1 pc)
Instruction manual HI930803 (1 pc)
Quality certificate (1 pc)
ISO 8655 burette compliance report (1 pc)
Reporting and Connection Options +
  • Tailor titration reports and store required Good Laboratory Practice (GLP) data
  • Export and transfer data to a USB flash drive or PC using the HI900PC application software
  • Print titration reports directly from this titrator using a standard parallel printer
  • Attach an external keyboard for added versatility
  • Connect an analytical balance to the titrator unit with a RS232 serial output. Helps save time with automatic sample weight entry and is ideal for back-weighing purposes
Blog +
    Specification Detail
    sku HI933-01
    Range 100 ppm to 100%
    Resolution 1 ppm to 0.0001%
    Result Units %, ppm, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg/pc, μg/pc
    Sample Type liquid or solid
    Pre-Titration Conditioning automatic
    Background Drift Correction automatic or user-selectable value
    Endpoint Criteria fixed mV persistence, relative drift stop or absolute drift stop
    Dosing dynamic with optional pre-dispensing
    Result Statistics mean, standard deviation
    Dosing Pump Resolution 1/40000 of the burette volume (0.125 μL per dose)
    Dosing Pump Accuracy ±0.1% of full burette volume
    Syringe 5 mL precision ground with PTFE plunger
    Valve motor-driven 3-way, PTFE liquid contact material
    Tubing PTFE with light block and thermal jacketing
    Dispensing Tip glass, fixed position, anti-diffusion
    Titration Vessel conical with operating volume between 50-150 mL
    Solvent Handling System sealed system, integrated diaphragm air pump
    Sensor Type HI76320 dual platinum pin polarization electrode
    Sensor Connection BNC
    Polarization Current 1, 2, 5, 10, 15, 20, 30 or 40 μA
    Voltage Range 2 mV to 1000 mV
    Voltage Resolution 0.1 mV
    Accuracy ±0.1%
    Programmable Stirrer magnetic, electronic regulated, digital stirrer 200 to 2000 rpm resolution 100 rpm
    Display 5.7in. (320 x 240 pixel) color LCD
    Methods up to 100 methods (standard and user-defined)
    Logging Data up to 100 complete titration reports and drift rate reports can be stored
    Peripherals (Rear) PC Connection, USB Flash Drive, Analytical Balance, Printer, External PC Keyboard
    GLP Conformity Good Laboratory Practice and instrument data storage and printing
    Languages English, Portuguese, Spanish, and French
    Enclosure Material ABS, PC and stainless steel
    Keypad polyester
    Operating Environment 10 to 40°C (50 to 104°F), up to 80% RH
    Storage Environment -20 to 70°C (-4 to 158°F), up to 95% RH
    Power Supply 100-240 Vac, 50/60 Hz
    Dimensions 315 x 205 x 375 mm (12.4 x 8.1 x 14.8")
    Weight approximately 4.3 kg (9.5 lbs.) with 1 pump, stirrer and sensors
    Warranty 2 years

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    HI933‑01 Karl Fischer Volumetric Titrator Instruction Manual
    Download
    Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Hanna Instruments HI933‑01 Karl Fischer Volumetric Titrator

Authorized Dealer
Accuracy capabilities +
  • Equipped with a dosing pump that offers an unmatched 40,000 step accuracy
  • Save and store up to 100 titration methods (either user-defined or standard). Customize methods to fit specific application needs or testing requirements. Easily program this titrator with standard methods that are in accordance with affiliations like ISO, ASTM, AOAC, AOCS, EPA and more
  • Operators can program this titrator unit with notification reminders for when to standardize the titrant
  • This titrator automatically calculates the average titer value and users can update the nominal concentration in the sample methods with the press of a button
  • Track progress in real-time. All important information is shown on the titrator's large LCD screen. Use the live titration curve during analysis to quickly recognize patterns and spot potential problems
  • Achieve high speed analysis without sacrificing accuracy with dynamic titrant dosing. This occurs by adjusting the volume of titrant dosed according to the mV response from the titrator reaction
  • Get more accurate measurements with automatic drift rate compensation. This corrects the titration calculation to account for the effects of any moisture that may enter the cell
  • Choose the endpoint termination criteria based on mV stability times or drift rates with the dual platinum pin electrode
  • Maintain data quality with the titration results averaging feature. Ideal for those operators who consistently run replicates of samples. The successive results from a titration method are averaged along with the standard deviation
  • Attain a reliable starting baseline with the multistage analysis. This works well for users that test multiple sample types with different methods for each
Durability and design details +
  • Manufactured to stand up to the harsh solvents and reagents used during titrations
  • Made with tough, chemically resistant materials including a strong casing as well as PTFE tubing with glass and stainless-steel components
  • Convenient-size, fits perfectly into any lab space
  • Simple to set up and user-friendly. Perfect for labs and businesses that have multiple personnel shift changes throughout the day
  • Intuitive screens and menus help operators navigate this titrator unit easily without getting lost in a nest of information
Safe and important operation features +
  • Introducing a solid or liquid sample to the titration vessel is simple and straightforward. Includes a quick-remove sample port with a replaceable rubber septum
  • Equipped with a sealed solvent management system and built-in air pumps. Users can move the reagent into waste and refill without physically touching the reagent. This makes testing seamless, eliminates manual chemical handling, and reduces the risk of contact or spills. The sealed solvent management system also mitigates excess moisture from getting into the cell
  • Standby mode keeps the solvent dry between titrations or when the titrator is not in use
  • Includes a rechargeable, color-indicating, silica gel desiccant. The desiccant changes color to alert users when its absorption capacity is depleted and needs to be recharged or replaced

Resources

What's Included +
Item Quantity / Notes
Karl Fischer Volumetric Titrator HI933 (1 pc)
Karl Fischer dual platinum pin electrode HI76320 (1 pc)
Dosing pump assembly HI930100 (1 pc)
Burette assembly HI930505 (1 pc)
Air pump and magnetic stirrer assembly HI930180 (1 pc)
Beaker assembly HI930520 (1 pc)
Beaker support (1 pc)
Pump locking screws with plastic head (2 pcs)
Titrant bottle assembly HI900530 (1 pc)
Solvent bottle assembly HI900531
Waste bottle assembly HI900531 (1 pc)
Calibration key HI900941 (1 pc)
Power supply HI900946 (1 pc)
USB cable HI920013 (1 pc)
USB flash drive HI930900U (1 pc)
Instruction manual HI930803 (1 pc)
Quality certificate (1 pc)
ISO 8655 burette compliance report (1 pc)
Reporting and Connection Options +
  • Tailor titration reports and store required Good Laboratory Practice (GLP) data
  • Export and transfer data to a USB flash drive or PC using the HI900PC application software
  • Print titration reports directly from this titrator using a standard parallel printer
  • Attach an external keyboard for added versatility
  • Connect an analytical balance to the titrator unit with a RS232 serial output. Helps save time with automatic sample weight entry and is ideal for back-weighing purposes
Blog +

Use this text to share information about your product.

Use this text to share information about your product.

Use this text to share information about your product.