Hanna Instruments HI12300 Digital PEI Body pH Electrode for Field Applications
Hanna Instruments HI12300 Digital PEI Body pH Electrode for Field Applications
Hanna Instruments HI12300 Digital PEI Body pH Electrode for Field Applications
Hanna Instruments HI12300 Digital PEI Body pH Electrode for Field Applications

Hanna Instruments HI12300 Digital PEI Body pH Electrode for Field Applications

$164.99

    The Hanna HI12300 digital PEI body pH electrode delivers fast, temperature-compensated field readings in a rugged, unbreakable probe. Its built-in microchip stores calibration data for instant plug-and-play use with Hanna edge® meters and HI83300-series photometers such as the HI83305.

    • Spherical general-purpose glass tip for fast, stable response
    • Double-junction, gel-filled design reduces silver contamination
    • Durable PEI body with glass-like chemical resistance - ideal for field and industrial use.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Built-In Microchip

Onboard digital intelligence stores sensor type, serial number, and calibration data including date, time, offset, slope, probe condition, and buffers used. When the HI12300 is connected to a Hanna edge® meter, this information is retrieved automatically so probes can be swapped without recalibration. All pH measurements occur inside the electrode and are sent digitally to the meter, reducing electrical noise that can appear with analog systems, built-in temperature sensors, or humid field conditions.

Spherical Glass Tip

A wide-contact spherical bulb increases sample surface area for faster response and more stable readings. The general-purpose glass formulation has a resistance of about 100 megaohms, which is optimized for ambient temperatures. High- or low-temperature glass used at room temperature can slow response or shorten electrode life.

Double Junction Reference

Silver stays isolated from the sample because the Ag/AgCl reference wire sits in an inner compartment while the outer electrolyte remains silver-free. Virtually no silver ions enter the measured solution, making the HI12300 suitable where silver contamination is undesirable or silver precipitates are likely to form at the junction.

PEI Electrode Body

Rugged PEI (polyetherimide) construction delivers the chemical resistance of glass in an unbreakable plastic housing built for field and industrial use. Shielding around the spherical glass tip helps prevent breakage from accidental bumps or drops, and the PEI body resists many harsh chemicals.

Built-In Temperature Sensor

A thermistor in the sensing tip provides a high-accuracy temperature reading as close as possible to the pH glass. That proximity allows proper compensation for temperature effects on membrane potential, producing reliable temperature-compensated pH results with the HI12300 digital PEI body electrode.

    Specification Detail
    SKU HI12300
    Description combination, digital pH electrode
    Reference double, Ag/AgCl
    Junction / Flow Rate ceramic, single / 15-20 µL/h
    Electrolyte gel
    Max Pressure 2 bar
    Range pH: 0 to 12
    Recommended Operating Temperature -5 to 70°C (23 to 158°F) - LT
    Tip / Shape spheric (dia: 7.5 mm)
    Temperature Sensor yes
    Matching Pin no
    Amplifier yes
    Body Material PEI
    Cable 1 m (3.3')
    Recommended Use field applications
    Connection 3.5 mm connector

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat