Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Hanna HI93721 Iron High Range Reagents, 100 or 300 Tests 100 tests Reagents Hanna Instruments
Hanna HI93721 Iron High Range Reagents, 100 or 300 Tests 300 tests Reagents Hanna Instruments
Hanna HI93721 Iron High Range Reagents, 100 or 300 Tests 100 tests Reagents Hanna Instruments
Hanna HI93721 Iron High Range Reagents, 100 or 300 Tests 300 tests Reagents Hanna Instruments

Hanna HI93721 Iron High Range Reagents, 100 or 300 Tests

$38.49

    Replenish your HI97721 iron-testing workflow. Genuine Hanna pre-measured reagents provide a choice of 100 or 300 high range tests with packet-level lot and expiration traceability.

    • HI93721-01: 100 tests; HI93721-03: 300 tests
    • HI97721 method: 0.00–5.00 mg/L as iron
    • Reagents only; instrument and cuvettes sold separately

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Keep your HI97721 ready for the next iron sample

Choose HI93721-01 for 100 tests or HI93721-03 for 300 tests. Both replenish the same iron high range method on the HI97721 photometer, making it straightforward to match your reagent order to your sample workload. These are reagent packs, not a meter kit.

Factory-measured powder doses reduce preparation steps. Hanna uses high-purity chemicals and marks the packets with a lot number and expiration date, helping you keep routine water-testing records tied to the reagent lot used.

HI93721-01 genuine Hanna Pre-measured powder packets — manufacturer reference photograph
Manufacturer reference photograph. Printed lot numbers and dates are illustrative, not the expiration date of supplied stock.

Matched chemistry for a defined measurement range

The phenanthroline chemistry produces an orange color whose intensity is measured by a compatible photometer. The reagent combines reducing and complexing functions; Hanna notes that it converts all but the most resistant iron forms to the ferrous, soluble state. The HI97721 method reports iron from 0.00 to 5.00 mg/L (ppm). The HI97721 method is an adaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method.

A straightforward HI97721 sample workflow

For the HI97721, zero the meter with 10 mL of unreacted sample. Add one packet of HI93721-0 Iron HR reagent, close the cuvette and shake gently until completely dissolved. Use the three-minute reaction countdown before reading. Follow the complete HI97721 manual for the sequence, interferences and temperature guidance.

Keep the cuvette exterior clean and dry, avoid bubbles and respect the specified reaction timing. Review the linked Safety Data Sheets before handling and arrange appropriate disposal of reagents and reacted samples.

Order the right reagent pack

HI93721-01 supplies enough reagent for 100 tests; HI93721-03 supplies enough for 300 tests. Each HI97721 test uses one packet. Choose a pack size that suits anticipated use before the expiration date on your supplied stock; the larger pack does not change the chemistry or measurement range. The photometer, cuvettes and CAL Check standards are not included.

Frequently Asked Questions

Which instrument is verified for these reagent packs?

Both HI93721-01 and HI93721-03 are explicitly listed in the HI97721 iron high range photometer manual. Use the full procedure for your exact instrument; this page does not claim compatibility with other iron Checkers.

What is the difference between the two pack options?

HI93721-01 provides enough reagent for 100 tests and HI93721-03 provides enough for 300 tests. Both use the same HI93721-0 iron high range reagent.

What iron range does the HI97721 method cover?

The HI97721 method covers 0.00 to 5.00 mg/L (ppm) as iron. A larger reagent pack increases test count, not the measuring range.

How much reagent and sample are used per test?

The HI97721 procedure uses one HI93721-0 powder packet with 10 mL of sample. Zero with unreacted sample before adding reagent.

How long is the HI97721 reaction time?

After adding the packet and gently shaking until dissolved, follow the three-minute countdown in the HI97721 procedure before the measurement.

Are the instrument and cuvettes included?

No. This listing supplies replacement reagents only. The compatible instrument, cuvettes, caps and calibration-check standards are separate products.

How can I check reagent traceability?

Read the lot number and expiration date on the supplied reagent packaging. Manufacturer photographs are illustrative; their printed dates do not identify the lot or expiration date you will receive.

What should I do before handling the reagents?

Read the linked Safety Data Sheets and the exact instrument procedure before testing. Use appropriate protection, keep cuvettes clean and dry outside, avoid bubbles and arrange suitable disposal of reagents and reacted samples.

    Product Specifications

    SpecificationDetail
    BrandHanna Instruments
    ParameterIron, high range
    Catalog numbersHI93721-01; HI93721-03
    Reagent formatPre-measured powder packets
    Verified compatible instrumentHI97721
    Method range on HI977210.00 to 5.00 mg/L (ppm) as iron (Fe)
    MethodAdaptation of Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method.
    Reagent per HI97721 testOne HI93721-0 packet with a 10 mL sample
    TraceabilityLot number and expiration date on packets

    Ordering Information

    SpecificationDetail
    HI93721-01Iron high range reagents, 100 tests
    HI93721-03Iron high range reagents, 300 tests

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat