Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Hanna HI93711 Total Chlorine Reagents, 100 or 300 Tests 100 tests | HI93711-01 Photometer Reagents Hanna Instruments
Hanna HI93711 Total Chlorine Reagents, 100 or 300 Tests 300 tests | HI93711-03 Photometer Reagents Hanna Instruments
Hanna HI93711 Total Chlorine Reagents, 100 or 300 Tests 100 tests | HI93711-01 Photometer Reagents Hanna Instruments
Hanna HI93711 Total Chlorine Reagents, 100 or 300 Tests 300 tests | HI93711-03 Photometer Reagents Hanna Instruments

Hanna HI93711 Total Chlorine Reagents, 100 or 300 Tests

$40.69

    Keep your HI97711 ready for total chlorine testing. Choose genuine Hanna pre-measured powder reagents with packet-level lot and expiration traceability.

    • HI93711-01: 100 tests; HI93711-03: 300 tests
    • HI97711 method: 0.00 to 5.00 mg/L as Cl₂
    • Reagents only; meter, cuvettes and CAL Check standards sold separately

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Keep your HI97711 ready for the next sample

Choose HI93711-01 for 100 tests or HI93711-03 for 300 tests. These genuine Hanna pre-measured powder reagents replenish total chlorine water-sample testing with the HI97711 portable photometer. The instrument, cuvettes, caps and CAL Check standards are sold separately.

Each packet is prepared with high-purity chemicals and marked with a lot number and expiration date for traceability. Select the test count that fits your sample workload; the pack size does not change the measurement range.

Hanna HI93711-01 Total Chlorine Reagents (100 tests), official manufacturer image
Manufacturer reference image. Packet appearance and printed dates are illustrative, not the expiration date of supplied stock.
Hanna HI93711-03 Total Chlorine Reagents (300 tests), official manufacturer image
Manufacturer reference image. Packet appearance and printed dates are illustrative, not the expiration date of supplied stock.

Matched chemistry for a defined photometer method

The DPD reaction develops a pink tint proportional to total chlorine concentration.

The HI97711 method measures 0.00 to 5.00 mg/L as Cl₂. These are powder reagents for the Total Chlorine (Powder) method, not the liquid A, B and C reagents in the separate HI93701-T set. Use a fresh, unreacted sample for each total or free chlorine determination.

A straightforward HI97711 sample workflow

Zero the HI97711 with 10 mL of unreacted sample in a clean cuvette. Add one packet of HI93711-0 reagent. Shake gently for 20 seconds, then follow the meter's 2 minutes 30 seconds reaction countdown before reading. The instrument method manual supplies the complete procedure, interference information and temperature guidance.

Keep the cuvette exterior clean and dry and avoid bubbles. Review the Safety Data Sheet before use and follow appropriate handling and disposal procedures. The photographs show manufacturer reference packaging; printed lot numbers and dates are illustrative, not a promise of the supplied stock expiration date.

What is included and what to have ready

Each selected pack supplies reagent for the stated 100 or 300 tests. Have a HI97711 photometer, suitable clean glass cuvettes with stoppers and caps, a water sample and the accessories required by the method ready separately. CAL Check standards verify the instrument; they do not replace reagents used to react with actual samples.

Choose your pack

HI93711-01 provides 100 tests for lower-volume replenishment. HI93711-03 provides 300 tests for a larger sample workload using the same chemistry. Consider expected usage and the expiration date on the supplied packets before selecting a pack.

Frequently Asked Questions

Are both packs compatible with HI97711?

Yes. The HI97711 method manual explicitly lists HI93711-01 for 100 tests and HI93711-03 for 300 tests. Use the matching method and do not assume compatibility with every Hanna meter.

What is the difference between HI93711-01 and HI93711-03?

The test count. HI93711-01 supplies enough reagent for 100 tests and HI93711-03 supplies enough for 300 tests. Both use the same HI93711-0 powder chemistry.

What measurement range does this method cover?

On the HI97711, the range is 0.00 to 5.00 mg/L as Cl₂. Use the complete procedure and range for your exact instrument; a larger reagent pack does not extend the range.

How much sample and reagent is needed?

The HI97711 method uses 10 mL of sample and one packet of HI93711-0 per determination. Zero the instrument with the unreacted sample before adding reagent.

How do I mix and time the reaction?

Shake gently for 20 seconds. Then use the 2 minutes 30 seconds countdown specified by the HI97711 method. Follow the manual for the full measurement sequence and temperature guidance.

Are these the same as CAL Check standards?

No. These sample reagents react with water samples to measure total chlorine. CAL Check standards are separate products for checking instrument performance, not substitutes for sample reagents.

Does the pack include the meter and cuvettes?

No. These are reagent-only replenishment options. The HI97711 photometer, cuvettes, caps, cleaning accessories and CAL Check standards are separately required or optional according to the method.

What should I check before handling or ordering?

Check the packet lot number and expiration date, review the linked HI93711-0 Safety Data Sheet and follow the method manual. These are powder reagents for the Total Chlorine (Powder) method, not the liquid A, B and C reagents in the separate HI93701-T set. Use a fresh, unreacted sample for each total or free chlorine determination.

    Product Specifications

    SpecificationDetail
    BrandHanna Instruments
    ParameterTotal Chlorine
    Catalog numbersHI93711-01; HI93711-03
    Reagent formatPre-measured powder packets
    MethodAdaptation of US EPA Method 330.5, DPD colorimetric method
    Compatible portable instrumentHI97711
    Method range on HI977110.00 to 5.00 mg/L as Cl₂
    Reagent per testOne packet of HI93711-0
    Sample volume10 mL
    MixingShake gently for 20 seconds
    Reaction countdown2 minutes 30 seconds
    TraceabilityLot number and expiration date on each packet

    Ordering Information

    SpecificationDetail
    HI93711-01100 tests
    HI93711-03300 tests

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat