Keep your HI97710 ready for pH indicator testing. Choose genuine Hanna method-matched chemistry with lot and expiration traceability.
Matched HI97710 photometer for this reagent chemistry.
Matched HI97736 photometer for this reagent chemistry.
Matched HI83326 photometer for this reagent chemistry.
Matched HI83300 photometer for this reagent chemistry.
Swipe or use the arrows to browse.
Choose HI93710-01 for 100 tests or HI93710-03 for 300 tests. These genuine Hanna reagents replenish pH indicator sample testing with the HI97710 and other explicitly matched photometers. The instrument, cuvettes, caps and CAL Check standards are sold separately.
Hanna prepares this chemistry with high-purity chemicals and marks the reagent packaging with a lot number and expiration date for traceability. Select the test count that fits your sample workload; the pack size does not change the measurement range.
Phenol red produces a yellow-to-red tint that varies with sample pH. A compatible photometer reads that response in pH units.
The HI97710 method measures 6.5 to 8.5 pH. HI93710 is a phenol red sample indicator for photometric pH measurement. It is not a pH calibration buffer, an electrode storage solution, a CAL Check standard, or the HI779-25 Pool Line reagent. HI97104 and HI971044 are different models: do not substitute this reagent for the HI971044 pH method.
Model-manual verified compatibility: HI83300, HI83303, HI83305, HI83306, HI83308, HI83326, HI83399, HI93102, HI97104, HI97710, HI97725, HI97736, HI97745. Use only the matching instrument method; this is not universal Hanna-meter compatibility.
For the HI97710 pH method, select pH, fill a clean cuvette with 10 mL of unreacted sample, fit the stopper and cap, and zero the instrument. Remove the cuvette, add five drops of HI93710-0 indicator, replace the stopper and cap, and swirl to mix. Reinsert the cuvette with the cap notch correctly positioned and press Read. The pH procedure does not specify a timed reaction countdown. Use the exact method for any other compatible instrument.
Keep the cuvette exterior clean and dry and avoid bubbles. Review the Safety Data Sheet before use and follow appropriate handling and disposal procedures. Manufacturer reference photographs show illustrative packaging only. Visible printed dates do not describe the supplied stock expiry; check the actual lot and expiration date on receipt.
Each selected pack supplies liquid phenol red indicator in dropper bottles for the stated 100 or 300 tests. Have a HI97710 photometer, suitable clean glass cuvettes with stoppers and caps, a water sample and the accessories required by the method ready separately. CAL Check standards verify the instrument; they do not replace reagents used to react with actual samples.
HI93710-01 provides 100 tests for lower-volume replenishment. HI93710-03 provides 300 tests for a larger sample workload using the same chemistry. Consider expected usage and the expiration date on the supplied reagent before selecting a pack.
HI93710-01 supplies reagent for 100 tests; HI93710-03 supplies reagent for 300 tests. Both use the same HI93710-0 chemistry. The larger pack changes test capacity, not the method range.
The model manuals list these reagent packs for HI83300, HI83303, HI83305, HI83306, HI83308, HI83326, HI83399, HI93102, HI97104, HI97710, HI97725, HI97736, HI97745. Select the matching method and follow your exact model manual; compatibility is not claimed for all Hanna meters.
The HI97710 method covers 6.5 to 8.5 pH. This is a limited-range photometric pH method, not a full-range electrode measurement. The HI97710 displays pH with 0.1 pH resolution.
The HI97710 method uses 10 mL of sample and Five drops of HI93710-0 per test. Zero using the unreacted sample first. Check the exact model manual for complete preparation and measurement instructions.
HI93710 is a phenol red sample indicator for photometric pH measurement. It is not a pH calibration buffer, an electrode storage solution, a CAL Check standard, or the HI779-25 Pool Line reagent. HI97104 and HI971044 are different models: do not substitute this reagent for the HI971044 pH method.
Only the selected reagent pack is supplied: liquid phenol red indicator in dropper bottles with capacity for 100 or 300 tests. The meter, cuvettes, caps, stoppers, cleaning accessories and CAL Check standards are not included. No meter or calibration standard is supplied.
Match HI93710-0 to the instrument method, choose a test count appropriate for your workload, and check the actual lot number and expiration date. Review the linked US Safety Data Sheet and use appropriate handling and disposal procedures. Manufacturer photos may show illustrative older packaging dates.
At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.
email us here: info@bluetigerscientific.com or live chat
Shipping and taxes calculated at checkout. Your quote list is separate.
Review your items, then tell Blue Tiger Scientific where your order is going. Your shopping cart stays unchanged.
International enquiries are welcome. Pricing, shipping availability, freight and any import requirements are confirmed manually.
Prices shown are for reference. We’ll confirm pricing, availability and shipping in your quote.
Optional preferences only. Terms must be confirmed by Blue Tiger Scientific; no payment is collected and no terms are approved by this request.
Loading the security check…
* Required. Contact details and eligible quote-cart items will be submitted to Blue Tiger Scientific for this enquiry. No payment is collected.