Hanna HI93710 pH Indicator Reagents, 100 or 300 Tests

$36.29

    Keep your HI97710 ready for pH indicator testing. Choose genuine Hanna method-matched chemistry with lot and expiration traceability.

    • HI93710-01: 100 tests; HI93710-03: 300 tests
    • HI97710 method: 6.5 to 8.5 pH
    • Reagents only; meter, cuvettes and CAL Check standards sold separately

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Keep your HI97710 ready for the next sample

Choose HI93710-01 for 100 tests or HI93710-03 for 300 tests. These genuine Hanna reagents replenish pH indicator sample testing with the HI97710 and other explicitly matched photometers. The instrument, cuvettes, caps and CAL Check standards are sold separately.

Hanna prepares this chemistry with high-purity chemicals and marks the reagent packaging with a lot number and expiration date for traceability. Select the test count that fits your sample workload; the pack size does not change the measurement range.

Hanna HI93710-01 pH Photometer Reagents (100 tests), official manufacturer image
HI93710-01 (100 tests): manufacturer reference photo. Packaging and printed dates are illustrative, not the expiry of supplied stock.

Matched chemistry for a defined photometer method

Phenol red produces a yellow-to-red tint that varies with sample pH. A compatible photometer reads that response in pH units.

The HI97710 method measures 6.5 to 8.5 pH. HI93710 is a phenol red sample indicator for photometric pH measurement. It is not a pH calibration buffer, an electrode storage solution, a CAL Check standard, or the HI779-25 Pool Line reagent. HI97104 and HI971044 are different models: do not substitute this reagent for the HI971044 pH method.

Model-manual verified compatibility: HI83300, HI83303, HI83305, HI83306, HI83308, HI83326, HI83399, HI93102, HI97104, HI97710, HI97725, HI97736, HI97745. Use only the matching instrument method; this is not universal Hanna-meter compatibility.

A straightforward HI97710 sample workflow

For the HI97710 pH method, select pH, fill a clean cuvette with 10 mL of unreacted sample, fit the stopper and cap, and zero the instrument. Remove the cuvette, add five drops of HI93710-0 indicator, replace the stopper and cap, and swirl to mix. Reinsert the cuvette with the cap notch correctly positioned and press Read. The pH procedure does not specify a timed reaction countdown. Use the exact method for any other compatible instrument.

Keep the cuvette exterior clean and dry and avoid bubbles. Review the Safety Data Sheet before use and follow appropriate handling and disposal procedures. Manufacturer reference photographs show illustrative packaging only. Visible printed dates do not describe the supplied stock expiry; check the actual lot and expiration date on receipt.

What is included and what to have ready

Each selected pack supplies liquid phenol red indicator in dropper bottles for the stated 100 or 300 tests. Have a HI97710 photometer, suitable clean glass cuvettes with stoppers and caps, a water sample and the accessories required by the method ready separately. CAL Check standards verify the instrument; they do not replace reagents used to react with actual samples.

Choose your pack

HI93710-01 provides 100 tests for lower-volume replenishment. HI93710-03 provides 300 tests for a larger sample workload using the same chemistry. Consider expected usage and the expiration date on the supplied reagent before selecting a pack.

Hanna HI93710-03 pH Photometer Reagents (300 tests), official manufacturer image
HI93710-03 (300 tests): manufacturer reference photo. Packaging and printed dates are illustrative, not the expiry of supplied stock.

Frequently Asked Questions

What is the difference between HI93710-01 and HI93710-03?

HI93710-01 supplies reagent for 100 tests; HI93710-03 supplies reagent for 300 tests. Both use the same HI93710-0 chemistry. The larger pack changes test capacity, not the method range.

Which instruments are verified for this reagent?

The model manuals list these reagent packs for HI83300, HI83303, HI83305, HI83306, HI83308, HI83326, HI83399, HI93102, HI97104, HI97710, HI97725, HI97736, HI97745. Select the matching method and follow your exact model manual; compatibility is not claimed for all Hanna meters.

What range and units apply?

The HI97710 method covers 6.5 to 8.5 pH. This is a limited-range photometric pH method, not a full-range electrode measurement. The HI97710 displays pH with 0.1 pH resolution.

How much sample and reagent do I use?

The HI97710 method uses 10 mL of sample and Five drops of HI93710-0 per test. Zero using the unreacted sample first. Check the exact model manual for complete preparation and measurement instructions.

How do I mix and read the sample?

For the HI97710 pH method, select pH, fill a clean cuvette with 10 mL of unreacted sample, fit the stopper and cap, and zero the instrument. Remove the cuvette, add five drops of HI93710-0 indicator, replace the stopper and cap, and swirl to mix. Reinsert the cuvette with the cap notch correctly positioned and press Read. The pH procedure does not specify a timed reaction countdown. Use the exact method for any other compatible instrument.

Is this a pH calibration buffer?

HI93710 is a phenol red sample indicator for photometric pH measurement. It is not a pH calibration buffer, an electrode storage solution, a CAL Check standard, or the HI779-25 Pool Line reagent. HI97104 and HI971044 are different models: do not substitute this reagent for the HI971044 pH method.

What is included, and is the meter supplied?

Only the selected reagent pack is supplied: liquid phenol red indicator in dropper bottles with capacity for 100 or 300 tests. The meter, cuvettes, caps, stoppers, cleaning accessories and CAL Check standards are not included. No meter or calibration standard is supplied.

What should I check before handling or choosing a pack?

Match HI93710-0 to the instrument method, choose a test count appropriate for your workload, and check the actual lot number and expiration date. Review the linked US Safety Data Sheet and use appropriate handling and disposal procedures. Manufacturer photos may show illustrative older packaging dates.

    Product Specifications

    SpecificationDetail
    BrandHanna Instruments
    ParameterpH Indicator
    Catalog numbersHI93710-01; HI93710-03
    Reagent formatLiquid phenol red indicator in dropper bottles
    MethodAdaptation of the Phenol Red Method
    Model-manual verified compatibilityHI83300, HI83303, HI83305, HI83306, HI83308, HI83326, HI83399, HI93102, HI97104, HI97710, HI97725, HI97736, HI97745
    Method range on HI977106.5 to 8.5 pH
    Method resolution on HI977100.1 pH
    Reagent per test on HI97710Five drops of HI93710-0
    Sample volume on HI9771010 mL
    Mixing on HI97710Swirl to mix
    Reading on HI97710Read after mixing; no timed pH countdown specified
    TraceabilityLot number and expiration date on reagent packaging
    IncludedSelected reagent pack only; meter, cuvettes, caps and CAL Check standards not included
    Selection noteHI93710 is a phenol red sample indicator for photometric pH measurement. It is not a pH calibration buffer, an electrode storage solution, a CAL Check standard, or the HI779-25 Pool Line reagent. HI97104 and HI971044 are different models: do not substitute this reagent for the HI971044 pH method.

    Ordering Information

    SpecificationDetail
    HI93710-01100 tests
    HI93710-03300 tests

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat