Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Hanna HI717-25 Phosphate High Range Checker Reagents, 40 Tests Default Title Reagents Hanna Instruments
Hanna HI717-25 Phosphate High Range Checker Reagents, 40 Tests Default Title Reagents Hanna Instruments

Hanna HI717-25 Phosphate High Range Checker Reagents, 40 Tests

$19.79

    Replenish your HI717 with the correct two-part chemistry. Genuine Hanna liquid-and-powder reagents provide 40 phosphate high range tests—not 25—with lot and expiration traceability.

    • HI717-25: enough reagent for 40 tests
    • For HI717 only: 0.0–30.0 ppm phosphate
    • Includes liquid and powder; instrument not included

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

A matched liquid-and-powder set for your HI717

HI717-25 replenishes the HI717 Phosphate High Range Checker HC with enough reagent for 40 tests. Despite the “-25” catalog suffix, this is a 40-test pack. It supplies a two-part liquid-and-powder chemistry, not the powder-only low range reagent used with the HI713.

The ready-made liquid and pre-measured powder packets keep routine preparation straightforward. Lot numbers and expiration dates on the dropper bottles and packets help maintain reagent traceability. Match both reagent components to the HI717 high range method before starting a test.

HI717-25 genuine Hanna Liquid HI717AS plus HI717B-0 powder packets — manufacturer reference photograph
Manufacturer reference photograph. Printed lot numbers and dates are illustrative, not the expiration date of supplied stock.

Matched chemistry for a defined measurement range

The HI717 uses an adaptation of the Heteropolymolybdenum Blue Method in Standard Methods for the Examination of Water and Wastewater, 18th Edition. The reaction with orthophosphate produces a blue tint that the HI717 reads as phosphate concentration from 0.0 to 30.0 ppm (mg/L). Follow the exact HI717 procedure rather than a low range phosphate method.

A straightforward HI717 sample workflow

Zero the HI717 with 10 mL of unreacted sample. Add 10 drops of HI717AS liquid reagent and the contents of one HI717B-0 powder packet. Replace the cap and shake gently until the powder is completely dissolved. Use the five-minute countdown before reading. The linked HI717 manual provides the full sequence and instrument guidance.

Keep the cuvette exterior clean and dry, avoid bubbles and respect the specified reaction timing. Review the linked Safety Data Sheets before handling and arrange appropriate disposal of reagents and reacted samples. Hanna restricts products classified as dangerous goods to ground shipping; confirm shipping eligibility before selecting an expedited service.

Order the right reagent pack

Each HI717-25 set supplies enough liquid and powder reagent for 40 high range phosphate tests. Both components are required for each test. The HI717 Checker, cuvettes and HI717-11 calibration-check standards are not included. Select this set for the HI717—not for the HI713—and plan consumption against the expiration dates on supplied stock.

Frequently Asked Questions

Is HI717-25 a 25-test or a 40-test pack?

It is a 40-test pack. Both the current Hanna reagent page and the HI717 manual specify 40 phosphate high range tests, despite the -25 catalog suffix.

Which Checker is compatible with this reagent set?

HI717-25 is verified for the HI717 Phosphate High Range Checker HC. It is not interchangeable with the HI713-25 low range reagent.

Which components are needed for each test?

The HI717 procedure requires 10 drops of HI717AS liquid reagent and one packet of HI717B-0 powder reagent. Both components are required; do not use the powder alone.

What range and units does the HI717 display?

The HI717 method measures 0.0 to 30.0 ppm as phosphate, equivalent to mg/L. Reagent replacement does not change the instrument range.

How long should I wait before reading the HI717?

After adding both reagents and gently shaking until the powder dissolves, use the five-minute countdown specified in the HI717 manual before reading.

Are the instrument and cuvettes included?

No. This listing supplies replacement reagents only. The compatible instrument, cuvettes, caps and calibration-check standards are separate products.

How can I check reagent traceability?

Read the lot number and expiration date on the supplied reagent packaging. Manufacturer photographs are illustrative; their printed dates do not identify the lot or expiration date you will receive.

What should I do before handling the reagents?

Read the linked Safety Data Sheets and the exact instrument procedure before testing. Use appropriate protection, keep cuvettes clean and dry outside, avoid bubbles and arrange suitable disposal of reagents and reacted samples.

    Product Specifications

    SpecificationDetail
    BrandHanna Instruments
    ParameterPhosphate, high range
    Catalog numberHI717-25
    Reagent formatLiquid HI717AS plus HI717B-0 powder packets
    Verified compatible instrumentHI717
    Method range on HI7170.0 to 30.0 mg/L (ppm) as phosphate
    MethodAdaptation of Standard Methods for the Examination of Water and Wastewater, 18th Edition, Heteropolymolybdenum Blue Method.
    Reagent per HI717 test10 drops HI717AS plus one HI717B-0 packet with a 10 mL sample
    TraceabilityLot number and expiration date on packets and dropper bottles

    Ordering Information

    SpecificationDetail
    HI717-25Phosphate high range liquid and powder reagents, 40 tests

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat