Skip to content

Global shipping available. Please request a quote to receive customized pricing for your region.

Hanna HI713-25 Phosphate Low Range Checker Reagents, 25 Tests Default Title Reagents Hanna Instruments
Hanna HI713-25 Phosphate Low Range Checker Reagents, 25 Tests Default Title Reagents Hanna Instruments

Hanna HI713-25 Phosphate Low Range Checker Reagents, 25 Tests

$20.89

    Keep your HI713 ready for low range phosphate samples. Genuine Hanna pre-measured powder reagents replenish 25 tests with packet-level lot and expiration traceability.

    • HI713-25: enough reagent for 25 tests
    • For HI713 only: 0.00–2.50 ppm phosphate
    • Powder method; instrument and cuvettes not included

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

Ready-to-use powder for your HI713 phosphate workflow

HI713-25 replenishes the HI713 Phosphate Low Range Checker HC with enough reagent for 25 tests. It is the powder-reagent choice for the low range method—not the liquid-and-powder reagent set used by the HI717 high range Checker. Match the reagent code to the HI713 before ordering.

Pre-measured packets simplify sample preparation without weighing out individual doses. Hanna prepares the reagents with high-purity chemicals and prints the lot number and expiration date on each packet to support traceable routine testing.

HI713-25 genuine Hanna Pre-measured powder packets — manufacturer reference photograph
Manufacturer reference photograph. Printed lot numbers and dates are illustrative, not the expiration date of supplied stock.

Matched chemistry for a defined measurement range

An adaptation of the Ascorbic Acid Method in Standard Methods for the Examination of Water and Wastewater, 20th Edition, produces a blue tint when phosphate reacts with the reagent. The HI713 measures that color and displays phosphate concentration in ppm, equivalent to mg/L, across its 0.00 to 2.50 ppm range.

A straightforward HI713 sample workflow

Zero the HI713 with 10 mL of unreacted sample in a clean cuvette. Add the contents of one HI713-0 powder packet, replace the cap and shake gently for two minutes until completely dissolved. Then use the three-minute countdown before measurement. Consult the downloadable HI713 manual for the complete operating sequence.

Keep the cuvette exterior clean and dry, avoid bubbles and respect the specified reaction timing. Review the linked Safety Data Sheets before handling and arrange appropriate disposal of reagents and reacted samples. Hanna restricts products classified as dangerous goods to ground shipping; confirm shipping eligibility before selecting an expedited service.

Order the right reagent pack

One HI713-25 pack contains reagent for 25 low range phosphate tests. No liquid reagent is required by this method. The HI713 Checker, cuvettes and HI713-11 calibration-check standards are separate products. Plan use against the expiration date printed on the packets; this pack does not extend the measuring range of the instrument.

Frequently Asked Questions

Which Checker uses HI713-25?

This reagent pack is verified for the HI713 Phosphate Low Range Checker HC. Do not substitute it for HI717-25 high range reagents or assume compatibility with a different Checker model.

How many tests are in one HI713-25 pack?

Hanna specifies enough reagent for 25 phosphate low range tests. The HI713 method uses one pre-measured powder packet per test.

What phosphate range can I measure?

On the HI713, the method covers 0.00 to 2.50 ppm as phosphate, equivalent to mg/L. This is not the HI717 high range method.

Does this method need liquid reagent?

No. The HI713 procedure adds one HI713-0 powder packet to 10 mL of sample. The HI717 liquid-and-powder method uses a different reagent set.

What mixing and reaction times should I follow?

The HI713 manual instructs gentle shaking for two minutes until powder dissolves, followed by a three-minute countdown before reading. Follow its complete zeroing and measurement sequence.

Are the instrument and cuvettes included?

No. This listing supplies replacement reagents only. The compatible instrument, cuvettes, caps and calibration-check standards are separate products.

How can I check reagent traceability?

Read the lot number and expiration date on the supplied reagent packaging. Manufacturer photographs are illustrative; their printed dates do not identify the lot or expiration date you will receive.

What should I do before handling the reagents?

Read the linked Safety Data Sheets and the exact instrument procedure before testing. Use appropriate protection, keep cuvettes clean and dry outside, avoid bubbles and arrange suitable disposal of reagents and reacted samples.

    Product Specifications

    SpecificationDetail
    BrandHanna Instruments
    ParameterPhosphate, low range
    Catalog numberHI713-25
    Reagent formatPre-measured powder packets
    Verified compatible instrumentHI713
    Method range on HI7130.00 to 2.50 mg/L (ppm) as phosphate
    MethodAdaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method.
    Reagent per HI713 testOne HI713-0 packet with a 10 mL sample
    TraceabilityLot number and expiration date on packets

    Ordering Information

    SpecificationDetail
    HI713-25Phosphate low range powder reagents, 25 tests

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat