Skip to content
Milwaukee MA911B/2 Industrial Grade Double Junction pH Electrode with Extended Cable Milwaukee Instruments
Milwaukee MA911B/2 Industrial Grade Double Junction pH Electrode with Extended Cable Milwaukee Instruments
Milwaukee MA911B/2 Industrial Grade Double Junction pH Electrode with Extended Cable Milwaukee Instruments
Milwaukee MA911B/2 Industrial Grade Double Junction pH Electrode with Extended Cable Milwaukee Instruments

Milwaukee MA911B/2 Industrial Grade Double Junction pH Electrode with Extended Cable

$64.98

    SKU: MA911B/2

    UPC: 810666009015

    MPN: MA911B/2

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Description

The MA911B/2 probe is lab grade, gel-filled pH probe for use with Milwaukee Monitors and Controllers.

Top Design Features:

Double Junction

The double junction junction design reduces the risk of clogging.

Spherical Glass Tip

The spherical glass tip provide the largest possible surface area for faster results.

Resin Body

The Polypropylene Resin body is tough to withstand accidental knocks and also protects the glass sensing bulb. It's high chemical resistance properties makes it ideal for Industrial applications, in-line applications and strong acids and bases.

Extended cable

Offers a 6.6' cable for increased flexibility in measuring.

Use and Care

pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.

Sensing bulb

The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.

Reference junction

The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.

You can extend the life of your pH electrode in the following ways:

Storage

The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

Storing in pH probe storage solution or pH calibration buffers will help address both these issues. Do not store in tap water or DI water. This will damage the sensitivity of the probe.

The best way to store the probe is with the probe's cap filled with storage solution or calibiration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.

Cleaning

Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution.

Calibration

The pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your PRO pH meter accurate. Also, calibrate after cleaning or a long period of storage.

    Specification Detail
    Body: Polypropylene Resin
    Reference: Double, Ag/AgCl
    Junction: Cloth, Single
    Electrolyte: Gel
    Range: 0-14 pH
    Tip Shape: Sphere
    Diameter: 0.5 inches
    Dimensions: 4.7 inches / 6.4 inches
    Operating Temperature: -5 to 70°C (23 to 158°F)
    Cable length: 6.6 feet
    Connection: BNC

    Milwaukee Instruments Warranty & Returns Policy
    (For Milwaukee Instruments ONLY – Not for Milwaukee Tools)

    How to Initiate a Return or Warranty Claim
    For products purchased through Blue Tiger Scientific, all returns must be initiated directly with us. However, all warranty claims must be handled directly through Milwaukee Instruments.

    Warranty Information
    Milwaukee Instruments products are manufactured to meet the highest quality standards and come with a limited warranty against defects in materials and workmanship. Products may be returned for repair or replacement at Milwaukee's discretion. Warranty is void if the product has been abused, misused, or repaired by unauthorized persons.

    To register your Milwaukee product, click here.

    Warranty Periods

    • Handheld testers, portable meters, and stationary monitors/controllers: 2 years
    • Bench meters: 3 years
    • PH600 pH Pen and similar versions: 1 year
    • Replaceable probes: 6 months

    Warranty begins on the original end-user purchase date or a maximum of 12 months from dealer purchase. Valid only with proper usage and maintenance. Service occurs at Milwaukee Instruments' North Carolina Technical Service Center.

    Note: Meters used in Kangen Water or “Negative ORP Water” applications are excluded from warranty coverage. Any warranty for these uses is null and void.

    Filing a Warranty Claim
    Contact Milwaukee Instruments Customer Service at (252) 443-3630 EST for an RMA number. Mark the RMA clearly on the box and ship prepaid. Improper packing can void the warranty.

    Return Policy (Blue Tiger Scientific)
    All purchases are final, but returns may be accepted under specific conditions:

    • Items must be in new condition with original packaging and contents.
    • Returns must be initiated within 14 days of purchase.
    • Subject to up to 30% restocking fee.
    • Customer pays all return shipping.
    • Initial shipping charges are non-refundable.

    Returns will be refused if packaging is damaged or contents are missing.

    Initiating a Return with Blue Tiger Scientific
    Contact Blue Tiger Scientific for an RMA and shipping instructions. Mark RMA clearly and pack securely to avoid transit damage. Shipping damage claims are the sender’s responsibility.

    Refunds, if eligible, will be processed within 5–10 business days. Credit card refunds may take longer to appear on your statement.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)