Skip to content
High Rheumatoid Factor Solution (Purified) Serum & Plasma Molecular Depot
High Rheumatoid Factor Solution (Purified) Serum & Plasma Molecular Depot
High Rheumatoid Factor Solution (Purified) Serum & Plasma Molecular Depot
High Rheumatoid Factor Solution (Purified) Serum & Plasma Molecular Depot

High Rheumatoid Factor Solution (Purified)

$795.00

    Catalog Number: B2010861P (1 mL)

    High Rheumatoid Factor Solution Purified consists of a concentrated solution of human Rheumatoid Factors (500-2499 IU/mL) that have been purified through several chromatography steps and supplied in buffer. Titer has been measured with the RF Latex method. This product can be used to test RF interference in immunoassays. Custom bulk amounts of this product are available upon request.

    Products are for in vitro research use only (RUO).

    Live Inquiry about this product via:

    Email: info@bluetigerscientific.com

    Text/SMS: (833) 928-4437 Mon–Fri, (8 am – 8 pm PST)

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

High Rheumatoid Factor Solution (Purified). 8 different clones are available.

Clone Catalog #
500-2499 IU/mL B2010861P-Z
> 25,000 IU/mL B2010861P-G
20,000-24,999 IU/mL B2010861P-F
15,000-19,999 IU/mL B2010861P-E
10,000- 14,999 IU/mL B2010861P-D
7,500-9,999 IU/mL B2010861P-C
5,000-7,499 IU/mL B2010861P-B
2,500-4,999 IU/mL B2010861P-A
Catalog number: B2010861P-Z
B2010861P-G
B2010861P-F
B2010861P-E
B2010861P-D
B2010861P-C
B2010861P-B
B2010861P-A
Lot number: Batch Dependent
Expiration Date: Batch dependent
Amount: 1 mL
Molecular Weight or Concentration: na
Supplied as: Purified Solution
Applications: Interference testing
Storage: -20°C
Keywords: Rheumatoid Factor Concentrate, Rheumatoid Factor (RF) Concentrate, high RF, RF > 2500 IU/mL, high RF solution

High Rheumatoid Factor Solution (Purified) is a biotechnology-grade reagent designed for precision interference testing and assay validation in immunodiagnostics. This solution contains purified rheumatoid factor (RF) at defined concentrations, ranging from 500 IU/mL to over 25,000 IU/mL, across eight distinct clones. Each clone offers a unique titer range, enabling researchers to simulate a wide spectrum of clinical conditions associated with autoimmune diseases, particularly rheumatoid arthritis.

Rheumatoid factor is a well-known source of assay interference, especially in immunoassays targeting IgG, cytokines, or cardiac biomarkers. This purified solution allows for controlled spiking into serum or plasma matrices to evaluate assay robustness, specificity, and cross-reactivity. It is ideal for developers of ELISA, CLIA, and nephelometric platforms seeking to meet regulatory standards for interference testing. Filtered through 0.22 µm membranes and supplied in 1 mL aliquots, the solution is stored at –20°C to preserve stability and activity. Whether you're validating a new diagnostic kit or troubleshooting unexpected signal drift, this reagent provides the consistency and flexibility needed for rigorous assay development.

Key benefits:

  • Purified RF solution available in eight defined titer ranges

  • Supports interference testing and assay validation workflows

  • Compatible with ELISA, CLIA, and nephelometric platforms

  • Filtered and biotechnology-grade for reproducible results

  • Supplied in 1 mL aliquots and stored at –20°C

Products are for in vitro research use only (RUO).


References

  • Rao DA, Gurish MF, Marshall JL, Slowikowski K, Fonseka CY, Liu Y, Donlin LT, Henderson LA, Wei K, Mizoguchi F, Teslovich NC, Weinblatt ME, Massarotti EM, Coblyn JS, Helfgott SM, Lee YC, Todd DJ, Bykerk VP, Goodman SM, Pernis AB, Ivashkiv LB, Karlson EW, Nigrovic PA, Filer A, Buckley CD, Lederer JA, Raychaudhuri S, Brenner MB. Pathologically expanded peripheral T helper cell subset drives B cells in rheumatoid arthritis Nature. 2017 Feb 1;542(7639):110-114.
  • Shi L, Hu F, Xu C, Zhu H, Qie D, Yuan C, Tao Y, Liu H. Plasma exchange successfully treated macrophage activation syndrome in rheumatoid factor-positive polyarticular juvenile idiopathic arthritis with co-existing pneumonia Int J Rheum Dis. 2018 May;21(5):1142-1145.
  • Bartlett DB, Willis LH, Slentz CA, Hoselton A, Kelly L, Huebner JL, Kraus VB, Moss J, Muehlbauer MJ, Spielmann G, Kraus WE, Lord JM, Huffman KM. Ten weeks of high-intensity interval walk training is associated with reduced disease activity and improved innate immune function in older adults with rheumatoid arthritis: a pilot study Arthritis Res Ther. 2018 Jun 14;20(1):127.
  • Fan W, Xu L, Xie L, Yang D, Liu X, Zhang J, Li Y, Yi C. Negative interference by rheumatoid factor of plasma B-type natriuretic peptide in chemiluminescent microparticle immunoassays PLoS One. 2014 Aug 21;9(8):e105304.
  • Taghadosi M, Samimi Z, Assar S, Salahshoor MR, Jalili C. Plasma Leptin Does Not Reflect the Effect of High Body Mass Index on Disease Activity in Rheumatoid Arthritis Immunol Invest. 2020 Feb;49(1-2):32-45.
  • Abildtrup M, Kingsley GH, Scott DL. Calprotectin as a biomarker for rheumatoid arthritis: a systematic review J Rheumatol. 2015 May;42(5):760-70.
  • Hughes-Austin JM, Deane KD, Giles JT, Derber LA, Zerbe GO, Dabelea DM, Sokolove J, Robinson WH, Holers VM, Norris JM. Plasma adiponectin levels are associated with circulating inflammatory cytokines in autoantibody positive first-degree relatives of rheumatoid arthritis patients PLoS One. 2018 Jun 25;13(6):e0199578.
  • Rantapää-Dahlqvist S, Boman K, Tarkowski A, Hallmans G. Up regulation of monocyte chemoattractant protein-1 expression in anti-citrulline antibody and immunoglobulin M rheumatoid factor positive subjects precedes onset of inflammatory response and development of overt rheumatoid arthritis Ann Rheum Dis. 2007 Jan;66(1):121-3.
  • Lovece S, Stern R, Kagen LJ. Effects of rheumatoid factor, antinuclear antibodies and plasma reagin on the serologic assay for Lyme disease J Rheumatol. 1991 Dec;18(12):1813-8.

    Terms & Conditions

    Blue Tiger Scientific is an independent third-party distributor of select products manufactured by Molecular Depot LLC. By purchasing from bluetigerscientific.com, you (“the Customer”) agree to the following terms, adapted from Molecular Depot’s original conditions:

    Product Use & Eligibility
    Products are for in vitro research use only (RUO). They are not intended for human or animal use, diagnosis, therapy, resale to consumers, or residential delivery. Sales are limited to verified business addresses.

    Payment Terms
    All purchases are prepaid and non-refundable once confirmed. Pricing is in USD and subject to change without notice.

    Purchase Orders
    Confirmed orders are final and may not be canceled or refunded unless authorized in writing.

    Limitation of Liability
    Blue Tiger Scientific and Molecular Depot LLC are not responsible for any damages resulting from product use or misuse.

    Waiver of Claims
    By ordering, you waive all claims arising from use of Molecular Depot products.

    Shipping & Handling
    Shipping is calculated at checkout. A minimum 27% handling fee applies to each order.

    Delivery Estimates All delivery timelines are estimates and not guaranteed. FedEx service levels are subject to operational delays, weather disruptions, and regional restrictions.

    FedEx Pickup Cutoff Orders submitted after the daily FedEx pickup window may not ship until the next available pickup day.

    Shipping Exceptions FedEx may impose restrictions or delays due to package size, weight, destination, or service availability. Blue Tiger Scientific is not liable for delays beyond our control.

    Weekend & Holiday Handling Orders placed on weekends or holidays will be processed on the next business day.

    Returns & Refunds
    Returns must be requested within 30 days through Blue Tiger Scientific. Refunds are only issued for shipping errors or verified defects, and processed within 45 business days if approved. Customers are responsible for return shipping costs unless otherwise stated. Refunds will exclude original shipping fees paid at checkout.

    Warranty Disclaimer
    All products are provided "as-is" with no warranties. Warranty issues are handled by the manufacturer.

    Safety Guidelines
    Always consult the product’s SDS. Products must not be ingested, inhaled, or come into contact with skin or eyes unless specified.

    Legal Use Compliance
    Products must not be used in violation of any law—local, state, federal, or international.

    Accuracy of Orders
    Customers are responsible for verifying all order details before submission.

    Changes or Cancellations
    All changes must be in writing and approved. Cancellations may result in fees for materials, labor, or third-party costs.

    Quality System (MD Levels)
    Molecular Depot’s MD-Quality System includes:

    MD 1000: Non-regulated use, no change notification

    MD 2000: Non-regulated use, limited change notification

    MD 3000: Regulated use, enhanced quality standards

    Delivery & Claims
    Orders may ship in parts. Claims for shortages or defects must be submitted within 2 days of receipt. Delivery dates are estimates only.

    Extended Payment Terms
    Payment is due within 30 days unless agreed otherwise. A 5% weekly penalty applies to late payments. Blue Tiger Scientific reserves discretion on payment application.

    Retention of Title
    Ownership remains with Blue Tiger Scientific or Molecular Depot LLC until payment is complete. Goods must be stored separately and labeled until paid in full.

    Intellectual Property
    No rights to manufacturing processes or IP are transferred. Blue Tiger Scientific is not liable for IP-related claims.

    Force Majeure
    Neither party is liable for delays or failures caused by uncontrollable events (e.g., weather, regulations, supply disruptions).

    Manufacturing Access
    Product purchase does not grant access to proprietary manufacturing documents or methods.

    Resale Prohibition
    Products cannot be resold without written approval from Molecular Depot LLC. Blue Tiger Scientific enforces this restriction.

    Governing Law
    Terms are governed by California and U.S. law. All disputes fall under U.S. jurisdiction.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)