Skip to content
Hanna Instruments HI98193 Waterproof Dissolved Oxygen & BOD Meter – Portable Field Design Portable DO/BOD Meter Hanna Instruments
Hanna Instruments HI98193 Waterproof Dissolved Oxygen & BOD Meter – Portable Field Design Portable DO/BOD Meter Hanna Instruments
Hanna Instruments HI98193 Waterproof Dissolved Oxygen & BOD Meter – Portable Field Design Portable DO/BOD Meter Hanna Instruments
Hanna Instruments HI98193 Waterproof Dissolved Oxygen & BOD Meter – Portable Field Design Portable DO/BOD Meter Hanna Instruments
Hanna Instruments HI98193 Waterproof Dissolved Oxygen & BOD Meter – Portable Field Design Portable DO/BOD Meter Hanna Instruments
Hanna Instruments HI98193 Waterproof Dissolved Oxygen & BOD Meter – Portable Field Design Portable DO/BOD Meter Hanna Instruments

Hanna Instruments HI98193 Waterproof Dissolved Oxygen & BOD Meter – Portable Field Design

$1,024.99

    Engineered for field and lab reliability, the Hanna Instruments HI98193 Waterproof Portable Dissolved Oxygen & BOD Meter delivers precise DO, BOD, barometric pressure, and temperature measurements in a rugged IP67-rated design. This portable meter is ideal for environmental, wastewater, and process applications, and comes complete with all necessary accessories in a durable carrying case.

    Preformed PTFE membrane and quick-connect probe for fast setup

    Ergonomic design supports single-handed operation in the field

    Complies with EPA and international standards for dissolved oxygen testing

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Key On-Screen Features

BOD Results Screen

BOD Results

BOD is automatically calculated based on the difference between initial and final DO concentrations.

BOD Parameters Screen

BOD Parameters & Records

Set test parameters and view a complete list of saved BOD test data directly on-screen.

OUR Results Screen

OUR Results

Oxygen Uptake Rate displayed in mg/L/hour for process control analysis.

SOUR Results Screen

SOUR Results

Specific Oxygen Uptake Rate calculated in mg/g VSS/hr for wastewater analysis.

Key Features:

  • Waterproof IP67 design with compact, ergonomic layout
  • Barometric pressure compensation with built-in barometer and 1-point calibration
  • Automatic temperature compensation via integrated temperature sensor
  • Manual salinity adjustment for saline water DO accuracy
  • Preloaded BOD, OUR, and SOUR test protocols
  • 400-reading on-demand logging with USB data transfer
  • Quick-connect DIN connector and field-replaceable PTFE membrane caps

Key Benefits:

  • Accurate DO and BOD results in the field or lab
  • Reduces setup time with quick-connect probe interface
  • Minimizes errors with advanced GLP tracking and logging
  • Offers flexibility for environmental, aquaculture, or wastewater professionals
  • Reliable performance even in high humidity or wet conditions
  • Accessible contextual help and multi-language interface
  • Bright, backlit LCD ensures visibility in all lighting conditions

    Specification Detail
    SKUHI98193
    Temperature Range-20.0 to 120.0 °C (-4.0 to 248.0 °F)
    Temperature Resolution0.1 °C (0.1 °F)
    Temperature Accuracy @ 25°C / 77°F±0.2 °C (±0.4 °F), excluding probe error
    Temperature CalibrationOne or two-point at any temperature value in range
    DO Range0.00 to 50.00 mg/L / 0.0 to 600.0 % saturation
    DO Resolution0.01 mg/L / 0.1 % saturation
    DO Accuracy (@25°C/77°F)±1.5 % of reading ±1 digit
    Barometric Pressure Range450 to 850 mmHg
    Barometric Pressure Resolution1 mmHg
    Barometric Accuracy±3 mmHg within ±15 % from calibration point
    Temperature CompensationAutomatic from 0.0 to 50.0 °C (32.0 to 122.0 °F)
    CalibrationAutomatic: one or two points (0 % and 100 %)
    Manual: one point entry in % saturation or mg/L
    Log FeatureLog-on-demand up to 400 samples
    ConnectivityPC connectivity via opto-isolated USB
    GLPYes
    Power Supply4 x 1.5V AA batteries
    Power ConsumptionApprox. 200 hours (50 hours with backlight)
    Environment0 to 50 °C (32 to 122 °F), max RH 100 %, IP67 rated
    Dimensions185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4 in.)
    Weight400 g (14.2 oz)
    Ordering InformationIncludes HI764073 DO probe, PTFE membrane caps (2), HI7041S electrolyte, zero oxygen solution, 100 mL beakers (2), PC software, USB cable, batteries, manuals, and rugged carrying case
    Warranty2 years
    Recommended ProbeHI764073 polarographic DO probe with temp sensor, DIN connector, and 4 m (13') cable

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    HI98193 Portable DO & BOD Meter Instruction Manual
    Download
    Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY