Skip to content
Hanna HI98162 Professional Portable Milk pH Meter Kit Portable Food pH Meter Hanna Instruments
Hanna HI98162 Professional Portable Milk pH Meter Kit Portable Food pH Meter Hanna Instruments
Hanna HI98162 Professional Portable Milk pH Meter Kit Portable Food pH Meter Hanna Instruments
Hanna HI98162 Professional Portable Milk pH Meter Kit Portable Food pH Meter Hanna Instruments
Hanna HI98162 Professional Portable Milk pH Meter Kit Portable Food pH Meter Hanna Instruments
Hanna HI98162 Professional Portable Milk pH Meter Kit Portable Food pH Meter Hanna Instruments
Hanna HI98162 Professional Portable Milk pH Meter Kit Portable Food pH Meter Hanna Instruments
Hanna HI98162 Professional Portable Milk pH Meter Kit Portable Food pH Meter Hanna Instruments

Hanna HI98162 Professional Portable Milk pH Meter Kit

$824.99

    Ensure optimal quality and safety in milk processing with the Hanna Instruments HI98162, a professional portable pH meter specifically engineered for accurate pH and temperature measurements in milk. This rugged, waterproof kit provides everything needed for precise testing right on the production floor.

    Specialized Milk pH Probe: Features the FC1013 probe, designed for reliable pH and temperature measurement in milk.

    Built for the Dairy Environment: IP67 waterproof rating and a durable carrying case ensure portability and protection for on-site testing.

    Comprehensive Data Management: Includes multiple language options and convenient USB connectivity for seamless data transfer and analysis.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Monitoring pH in milk is essential for identifying spoilage, detecting infection, and optimizing processing techniques. Fresh milk typically has a pH of 6.7. Deviations from this value can indicate contamination—lower pH suggests bacterial degradation, while higher pH may signal mastitis infection. Quick pH screening helps producers assess quality and diagnose potential issues in the milk supply chain.

Spoilage is commonly caused by lactic acid bacteria, which convert lactose into lactic acid, eventually causing curdling and sour taste. Conversely, elevated pH levels may point to mastitis, a common udder infection, where the presence of alkaline blood plasma shifts the milk’s pH above the norm. This can be confirmed by somatic cell count, but pH testing offers a rapid preliminary check.

In high-temperature pasteurization operations, even slight pH shifts can affect process timing and stability. However, accurate pH measurement in milk can be difficult due to high solids content that may coat the electrode or clog the junction. The HI98162 solves this with the FC1013 electrode, engineered with a food-safe PVDF body that resists chemical exposure, abrasion, and microbial growth. Its quick-connect DIN interface ensures a waterproof, secure fit for reliable data collection in dairy environments.

FSMA Compliant

This pH meter meets the FDA Food Safety Modernization Act (FSMA) compliance standards.

Foodcare Electrode FC1013

The FC1013 electrode paired with the HI98162 is purpose-built for milk testing, offering consistent and precise readings across raw and processed dairy samples. Its integrated temperature sensor enables automatic compensation without requiring additional probes, ensuring accurate results across a wide thermal range.

PVDF Body

Constructed from chemically resistant, food-grade PVDF plastic, the electrode is durable and suited for both on-farm and in-plant testing scenarios.

Spheric Glass Tip

The spherical sensing bulb maximizes contact with aqueous milk samples, improving stability and calibration accuracy.

Built-In Temperature Sensor

With Automatic Temperature Compensation built-in, this sensor helps eliminate reading drift caused by temperature fluctuations.

The HI98162 integrates Hanna's advanced CAL Check™ diagnostic technology to detect calibration issues and prevent measurement errors often caused by milk solids coating the electrode. Users are notified via on-screen prompts if the probe requires cleaning, replacement, or if calibration buffers are compromised. Post-calibration, the system displays electrode condition as a percentage, based on slope and offset.

With the AutoHold function, a stable reading is automatically logged and frozen on screen. Users can also enable out-of-range alerts to warn when measurements fall outside calibrated limits. Up to 200 sample readings can be stored with full GLP traceability, accessible via the dedicated GLP key or transferred to a PC using the micro USB cable and Hanna software.

A context-sensitive help feature is available at any time via a dedicated button, providing immediate guidance based on the current display screen.

The high-contrast, backlit LCD ensures visibility in all lighting conditions. Combined with virtual and physical buttons and multiple language support, the HI98162 offers intuitive and flexible user navigation.

Included with the HI98162 is a rugged, thermoformed HI720161 carrying case designed to protect and organize all required accessories—including the meter, FC1013 electrode, beakers, and calibration solutions—for streamlined field testing.

Key On-Screen Features

Intuitive Setup Screen

Intuitive Setup

Easily configure system parameters including time, date, temperature units, and display language preferences.

Guided Calibration Screen

Step-by-Step Calibration

Benefit from CAL Check™ and guided visual prompts to ensure accurate calibration and performance.

Comprehensive GLP Data Screen

GLP Records

Quickly access calibration history including buffer data, timestamps, slope, and offset values.

Key Features:

  • Durable waterproof IP67 enclosure designed for tough field conditions.
  • Supplied with the FC1013 Foodcare pH/Temperature electrode tailored for milk analysis.
  • Food-grade PVDF electrode body is chemical and abrasion resistant.
  • Open junction design helps prevent clogging from solids.
  • Built-in temperature sensor ensures accurate compensated readings.
  • Five-point pH calibration with seven standard and five custom buffer options.
  • CAL Check™ diagnostics for calibration accuracy and electrode health.
  • AutoHold function automatically logs stable readings.
  • Log-on-demand enables immediate data capture with 200 sample memory.
  • PC connectivity via USB for data export and analysis.

Key Benefits:

  • Delivers fast, reliable pH measurements tailored for the dairy industry.
  • Minimizes downtime and errors with proactive maintenance alerts.
  • Improves measurement confidence with robust GLP tracking and audit support.
  • Ensures quality control in pasteurization and raw milk processing.
  • Facilitates traceability and regulatory compliance with easy-to-access calibration logs.
  • Enhances workflow efficiency with intuitive menus and context-sensitive help.
  • Clear backlit LCD screen provides excellent readability in any lighting.
  • Long battery life ensures continuous performance in the field.
    Specification Detail
    SKU HI98162
    pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH
    pH Resolution 0.1 pH / 0.01 pH / 0.001 pH
    pH Accuracy @ 25°C / 77°F ±0.1 pH / ±0.01 pH / ±0.002 pH
    pH Calibration Up to five point calibration, seven standard buffers available (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and five custom buffers
    mV Range ±2000.0 mV
    mV Resolution 0.1 mV
    mV Accuracy ±0.2 mV
    Temperature Range -20.0 to 120.0 °C (-4.0 to 248.0 °F)
    Temperature Resolution 0.1 °C (0.1 °F)
    Temperature Accuracy @ 25°C / 77°F ±0.4 °C (±0.8 °F) (excluding probe error)
    Temperature Compensation Automatic
    Log Feature On demand, 200 samples (100 pH and 100 mV)
    Connectivity PC Connectivity opto-isolated USB
    GLP Yes
    Power Supply 1.5V AA batteries (4 pcs.)
    Power Consumption approx. 200 hours of continuous use without backlight (50 hours with backlight)
    Environment 4 to 50 °C (32 to 122 °F) max. RH 100% IP67
    Dimensions 189 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in.)
    Weight 404 g (14.2 oz)
    Ordering Information HI98162 is supplied with FC1013 PVDF body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700640 electrode cleaning solution for milk deposits sachet (2), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual with quick start guide, instrument quality certificate and HI720161 hard carrying case.
    Warranty 2 years
    Recommended Probe FC1013 pre-amplified pH probe with internal temperature sensor, quick connect DIN connector and 1 m (3.3') cable (included)

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    HI98162 Professional Portable Milk pH Meter Instruction Manual
    Download
    Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)