Skip to content
Hanna Instruments HI83326-01 Pool & Spa Photometer with pH Meter Benchtop Photometer Hanna Instruments
Hanna Instruments HI83326-01 Pool & Spa Photometer with pH Meter Benchtop Photometer Hanna Instruments
Hanna Instruments HI83326-01 Pool & Spa Photometer with pH Meter Benchtop Photometer Hanna Instruments
Hanna Instruments HI83326-01 Pool & Spa Photometer with pH Meter Benchtop Photometer Hanna Instruments
Hanna Instruments HI83326-01 Pool & Spa Photometer with pH Meter Benchtop Photometer Hanna Instruments
Hanna Instruments HI83326-01 Pool & Spa Photometer with pH Meter Benchtop Photometer Hanna Instruments

Hanna Instruments HI83326-01 Pool & Spa Photometer with pH Meter

$874.99

    Take control of pool and spa water quality with the Hanna Instruments HI83326-01 Pool & Spa Photometer, a compact, high-performance benchtop meter designed to deliver lab-grade accuracy right where you need it. Engineered with an advanced optical system and a digital pH/temperature electrode input, this multiparameter photometer measures 11 essential parameters like free chlorine, alkalinity, and phosphate—ensuring crystal-clear water and a safe, healthy environment. Whether you're a pool professional or a facility manager, this versatile meter saves time, space, and hassle by combining photometric and pH testing into one powerful unit.

    • Measures 11 critical pool & spa parameters including free chlorine and phosphate

    • Dual-function as a photometer and digital pH meter—maximize your benchtop space

    • Advanced optical design ensures unmatched accuracy and reliability

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Overview: The HI83326 is a versatile benchtop photometer designed specifically for pool and spa professionals. With 12 advanced methods to measure 11 essential water quality parameters, this meter uses a cutting-edge optical system with LEDs, interference filters, and dual detectors to ensure unmatched accuracy and repeatability.

Reliable disinfection is critical for healthy recreational water systems. This instrument helps maintain ideal chlorine, bromine, pH, alkalinity, and calcium hardness levels—key to avoiding harmful bacteria, algae, corrosion, or scale. For added efficiency, the built-in digital pH input allows rapid pH analysis with intelligent electrode recognition and hot-swapping.

Educators and advanced users benefit from the absorbance mode, which supports custom concentration plots and Beer-Lambert Law demonstrations at three selectable wavelengths. Dual USB ports streamline data transfer or power supply, while the integrated rechargeable battery ensures operation even on the move.

Note: Reagents are not included with the meter but can be purchased separately.

IDEAL APPLICATIONS: Pool & Spa Maintenance, Recreational Water Safety, Hotel & Resort Water Management, Environmental Monitoring, Educational Labs.

On-Screen Features

Method Selection

Method Selection

Select from 20 pre-programmed testing methods using the intuitive METHOD button to simplify setup and analysis.

Data Logging

Data Logging

Save up to 1000 measurements complete with user and sample IDs, easily accessible for traceable water quality records.

pH Measurement Mode

pH Measurement Mode

Operate as a professional pH meter with automatic temperature compensation, two-point calibration, and GLP tracking.

Key Features:

  • Digital Electrode Input: Measures pH and temperature with traceable calibration and smart probe recognition.
  • Powerful Logging Capabilities: Stores 1000 readings with optional sample/user IDs for efficient recordkeeping.
  • USB Export Functionality: Transfer data to a computer or flash drive as .CSV files for analysis and reporting.
  • Battery and Error Feedback: On-screen indicators show power status and diagnostic messages for easy troubleshooting.
  • Photometric Absorbance Mode: Use CAL Check™ cuvettes to validate accuracy and create custom absorbance curves.

Key Benefits:

  • Precision Optical Components: Dual-detector system stabilizes light output for consistent test results.
  • Reliable Water Balance: Ensures safe chlorine, pH, and calcium levels to protect swimmers and equipment.
  • Educational Flexibility: Supports interactive absorbance-based learning and method development.
  • Portable Bench Convenience: USB power option and rechargeable battery allow mobile use when needed.
  • All-in-One Instrument: Combines photometric and pH measurement capabilities in a compact benchtop format.

Advanced Optical System

Innovative Design

A beam splitter divides light between the sample and a reference detector, ensuring stable intensity and high accuracy even during power or temperature changes.

High Efficiency LED Light Source

LEDs provide high luminosity with low heat output, outperforming tungsten lamps and offering more consistent output, especially in blue and violet wavelengths.

High-Quality Narrow Band Filters

Filters ensure ±1 nm wavelength accuracy and up to 95% light transmission, improving signal strength and reducing measurement error.

Reference Detector Stability

Internal reference monitoring corrects for drift caused by ambient conditions, preserving consistency between blank and sample readings.

25 mm Cuvette Compatibility

The wide optical path enhances accuracy and minimizes rotation-based errors during testing, especially for low absorbance samples.

Focusing Lens Precision

All emitted light is directed precisely onto the silicon detector, reducing the impact of scratches or imperfections in the cuvette glass.

Photometric Measurement Parameters

Parameter Range Resolution Accuracy (at 25 °C) Method Wavelength Reagent Code
Absorbance 0.000 to 4.000 Abs 0.001 Abs +/-0.003 Abs @ 1.000 Abs
Alkalinity 0 to 500 mg/L (as CaCO₃) 1 mg/L ±5 mg/L ±5% of reading Colorimetric Method 610 nm HI775-26
Bromine 0.00 to 8.00 mg/L (as Br₂) 0.01 mg/L ±0.08 mg/L ±3% of reading DPD Method 525 nm HI93716-01
Chlorine, Free 0.00 to 5.00 mg/L (as Cl₂) 0.01 mg/L ±0.03 mg/L ±3% of reading EPA DPD Method 330.5 525 nm HI93701-01
Chlorine, Total 0.00 to 5.00 mg/L (as Cl₂) 0.01 mg/L ±0.03 mg/L ±3% of reading EPA DPD Method 330.5 525 nm HI93711-01
Copper, High Range 0.00 to 5.00 mg/L (as Cu) 0.01 mg/L ±0.02 mg/L ±4% of reading EPA Method 575 nm HI93702-01
Cyanuric Acid 0 to 80 mg/L (as CYA) 1 mg/L ±1 mg/L ±15% of reading Turbidimetric Method 525 nm HI93722-01
Hardness, Calcium 0.00 to 2.70 mg/L (as CaCO₃) 0.01 mg/L ±0.11 mg/L ±5% of reading Calmagite Method 525 nm HI93720-01
Iron, Low Range 0.000 to 1.600 mg/L (as Fe) 0.001 mg/L ±0.010 mg/L ±8% of reading TPTZ Method 575 nm HI93746-01
Iron, High Range 0.00 to 5.00 mg/L (as Fe) 0.01 mg/L ±0.04 mg/L ±2% of reading Phenanthroline Method 315B 525 nm HI93721-01
Nitrate 0.0 to 30.0 mg/L (as NO₃⁻-N) 0.1 mg/L ±0.5 mg/L ±10% of reading Cadmium Reduction Method 525 nm HI93728-01
Ozone 0.00 to 2.00 mg/L (as O₃) 0.01 mg/L ±0.02 mg/L ±3% of reading DPD Method 525 nm HI93757-01
pH 6.5 to 8.5 pH 0.1 pH ±0.1 pH Phenol Red Method 525 nm HI93710-01
    Specification Detail
    skuHI83326-01
    Wavelength Accuracy±1 nm
    Light Source5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters
    Spectral bandwidth8 nm
    Input Channels1 pH electrode input and 5 photometer wavelengths
    pH Electrodedigital pH electrode (not included)
    Logging Typelog on demand with user name and sample ID optional input
    Logging Memory1000 readings
    ConnectivityUSB-A host for flash drive, micro-USB-B for power and computer connectivity
    GLPcalibration data for connected pH electrode
    Display128 x 64 pixel LCD with backlight
    Battery Type / Life3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
    Power Supply5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
    Environment0 to 50.0°C (32 to 122.0°F), 0 to 95% RH, non-condensing
    Dimensions206 x 177 x 97 mm (8.1 x 7.0 x 3.8)
    Weight1.0 kg (2.2 lbs.)
    Photometer/Colorimeter Light Detectorsilicon photodetector
    Cuvette Typeround, 24.6 mm
    Number of Methods128 max.
    Ordering InformationSupplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
    Warranty2 years
    Note*Reagents are not included.

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    HI83326 Pool and Spa Photometer Instruction Manual
    Download
    Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)