Hanna Instruments HI83306-01 Environmental Analysis Photometer for COD & Water Quality Benchtop Photometer Hanna Instruments
Hanna Instruments HI83306-01 Environmental Analysis Photometer for COD & Water Quality Benchtop Photometer Hanna Instruments
Hanna Instruments HI83306-01 Environmental Analysis Photometer for COD & Water Quality Benchtop Photometer Hanna Instruments
Hanna Instruments HI83306-01 Environmental Analysis Photometer for COD & Water Quality Benchtop Photometer Hanna Instruments

Hanna Instruments HI83306-01 Environmental Analysis Photometer for COD & Water Quality

$754.99

    The Hanna Instruments HI83306-01 Environmental Analysis Photometer delivers unparalleled accuracy for critical water quality testing, including COD, nitrate, phosphorus, and dissolved oxygen. Its innovative optical system and digital pH electrode input make it the ultimate all-in-one solution for both lab and field environmental analysis.

    Multiparameter powerhouse: Measures 16 key water quality parameters.

    Space-saving design: Doubles as a professional laboratory pH meter.

    Customizable: Features an absorbance mode for user-developed curves.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Overview: The Hanna Instruments HI83306 Environmental Analysis Photometer is a compact, benchtop instrument designed for comprehensive water quality monitoring. It offers 23 distinct methods to measure 16 key environmental parameters, including critical nutrients like nitrates and phosphates, and dissolved oxygen. Its advanced optical system, featuring precision LEDs, narrow band interference filters, and a focusing lens, combined with both an absorbance photodetector and a reference detector, ensures consistently accurate and repeatable photometric measurements.

This versatile photometer is engineered to address the most common challenges in environmental water quality. Precise measurement of parameters like nitrates and phosphates is vital for managing nutrient pollution in agricultural runoff, which can lead to harmful algal blooms and negatively impact aquatic ecosystems. Similarly, accurate dissolved oxygen levels are essential for sustaining healthy aquatic life and microbial processes within water bodies.

Beyond its photometric capabilities, the HI83306 doubles as a professional pH meter through its digital pH electrode input. This innovative feature allows the pH electrode to store its own calibration data, enabling seamless "hot-swapping" without the need for frequent recalibrations and providing automatic temperature compensation for superior accuracy. Additionally, an integrated absorbance measuring mode supports CAL Check™ validation and allows users to develop custom concentration curves across multiple wavelengths (420 nm, 525 nm, 575 nm, and 610 nm), making it ideal for custom chemistry or educational applications.

Equipped with dual USB ports, the HI83306 facilitates effortless data transfer to flash drives or computers, exporting readings as .CSV files. For enhanced portability and field use, the meter also operates on an internal 3.7 VDC rechargeable Lithium-polymer battery, offering reliable performance for both laboratory and on-site environmental analysis.

Note: Reagents are not included with the meter.

IDEAL APPLICATIONS: Environmental Water Quality Monitoring, Wastewater Treatment, Drinking Water Analysis, Aquatic Ecosystem Health, Agricultural Runoff Analysis, Research & Education.

Key Features:

Digital pH Electrode Input

  • Measure pH and temperature with a single digital probe.
  • Supports Good Laboratory Practice (GLP) for tracking calibration data including date, time, buffers, offset, and slope.
  • Utilizes pH CAL Check™ to alert users to potential calibration issues.
  • Conserves bench space by combining pH meter and photometer functions.

Data Logging

  • Store up to 1000 photometric and pH readings with a dedicated LOG button, easily recalled via the RCL button.
  • Allows for optional sample ID and user ID input using the alphanumeric keypad for comprehensive traceability.

Connectivity

  • Transfer logged readings quickly to a flash drive via the USB-A host port or to a computer using the micro USB-B port.
  • Exports data in .CSV format, compatible with standard spreadsheet programs for easy analysis.

Error Messages & Indicators

  • Provides photometric error messages for issues like missing cuvette caps, high zero, or low standards.
  • Offers pH calibration messages to guide users on electrode maintenance and calibration accuracy (e.g., clean electrode, check buffer, check probe).
  • Includes a battery status indicator to display remaining power.

Key Benefits:

Backlit Graphic LCD Display

  • Ensures easy viewing of readings even in low-light conditions.
  • Features a simplified user interface with virtual keys and on-screen help for intuitive operation.

Built-in Reaction Timer

  • Automatically initiates measurements after the countdown, ensuring consistent reaction intervals for all readings.
  • Enhances measurement consistency and reliability across different users.

Absorbance Mode Versatility

  • Allows for system performance validation using Hanna's exclusive CAL Check™ cuvettes.
  • Enables users to plot custom concentration vs. absorbance curves for bespoke chemical methods or for educational purposes following Beer-Lambert Law principles.

Automated Data Conversion

  • Converts readings to different chemical forms with a single touch, simplifying reporting and analysis.

Protective Cuvette Cover

  • Prevents stray light from interfering with measurements, ensuring optimal accuracy.

On-Screen Features

Method Selection

Method Selection

Effortlessly choose from 23 pre-programmed measurement methods using the dedicated METHOD button for simplified setup.

Data Logging

Data Logging

Store up to 1000 photometric and pH readings with optional user and sample IDs, easily accessible for complete data traceability.

pH Measurement Mode

pH Measurement Mode

Utilize the photometer as a professional pH meter, complete with temperature-compensated measurements, two-point auto calibration, and GLP tracking.

Advanced Optical System

Innovative Design

HI83306 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer.

High Efficiency LED Light Source

An LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue/violet light output.

High Quality Narrow Band Interference Filters

The narrow band interference filter not only ensure greater wavelength accuracy (+/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.

Reference Detector for a Stable Light Source

A beam splitter is used as part of the internal reference system of the HI83306 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.

Large Cuvette Size

The sample cell of the HI83306 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Focusing Lens for Greater Light Yield

Adding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.

Parameters

Parameter Range Resolution Accuracy (at 25 °C) Method Wavelength Reagent Code
Absorbance 0.000 to 4.000 Abs 0.001 Abs +/-0.003Abs @ 1.000 Abs
Ammonia, Low Range 0.00 to 3.00 mg/L (as NH3 -N) 0.01 mg/L ±0.04 mg/L ±4% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method. 420 nm HI93700-01
Ammonia, Medium Range 0.00 to10.00 mg/L (as NH3-N) 0.01 mg/L ±0.05 mg/L ±5% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method 420 nm HI93715-01
Ammonia, High Range 0.0 to 100.0 mg/L (as NH3 -N) 0.1 mg/L ±0.5 mg/L ±5% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method 420 nm HI93733-01
Chlorine, Free 0.00 to 5.00 mg/L (as Cl2 ) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93701-01
Chlorine, Total 0.00 to 5.00 mg/L (as Cl2 ) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the EPA DPD method 330.5 525 nm HI93711-01
Chromium (VI), Low Range 0 to 300 µg/L (as Cr(VI)) 1 µg/L ±10 µg/L ±4% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide method 525 nm HI93749-01
Chromium (VI), High Range 0 to 1000 µg/L (as Cr(VI)) 1 µg/L ±5 µg/L ±4% of reading at 25 °C Adaptation of the ASTM Manual of Water and Environmental Technology, D1687, Diphenylcarbohydrazide method 525 nm HI93723-01
Color of Water 0 to 500 PCU (Platinum Cobalt Units) 1 PCU ±10 PCU ±5% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method 420 nm
Copper, Low Range 0.000 to 1.500 mg/L (as Cu) 0.001 mg/L ±0.010 mg/L ±5% of reading Adaptation of the EPA method 575 nm HI95747-01
Copper, High Range 0.00 to 5.00 mg/L (as Cu) 0.01 mg/L ±0.02 mg/L ±4% of reading Adaptation of the EPA method 575 nm HI93702-01
Cyanuric Acid 0 to 80 mg/L (as CYA) 1 mg/L ±1 mg/L ±15% of reading Adaptation of the turbidimetric method 525 nm HI93722-01
Molybdenum 0.0 to 40.0 mg/L (as Mo6+) 0.1 mg/L ±0.3 mg/L ±5% of reading Adaptation of the mercaptoacetic acid method 420 nm HI93730-01
Nickel, Low Range 0.000 to 1.000 mg/L (as Ni) 0.001 mg/L ±0.010 mg/L ±7% of reading Adaptation of the PAN method 575 nm HI93740-01
Nickel, High Range 0.00 to 7.00 g/L (as Ni) 0.01 g/L ±0.07g/L ±4% of reading Adaptation of the photometric method 575 nm HI93726-01
Nitrate 0.0 to 30.0 mg/L (as NO3 - N) 0.1 mg/L ±0.5 mg/L ±10% of reading Adaptation of the cadmium reduction method 525 nm HI93728-01
Nitrite, High Range 0 to 150 mg/L (as NO2-) 1 mg/L ±4 mg/L ±4% of reading Adaptation of the Ferrous Sulfate method 575 nm HI93708-01
Oxygen, Dissolved 0.0 to 10.0 mg/L (as O2 ) 0.1 mg/L ±0.4 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method 420 nm HI93732-01
pH 6.5 to 8.5 pH 0.1 pH ±0.1 pH Adaptation of the Phenol Red method 525 nm HI93710-01
Phosphate, Low Range 0.00 to 2.50 mg/L (as PO4 3-) 0.01 mg/L ±0.04 mg/L ±4% of reading Adaptation of the Ascorbic Acid method 610 nm HI93713-01
Phosphate, High Range 0.0 to 30.0 mg/L(as PO43-) 0.1 mg/L ±1.0 mg/L ±4% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method 525 nm HI93717-01
Silica, Low Range 0.00 to 2.00 mg/L (as SiO2 ) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method 610 nm HI93705-01
Silver 0.000 to 1.000 mg/L (as Ag) 0.001 mg/L ±0.020 mg/L ±5% of reading Adaptation of the PAN method 575 nm HI93737-01
Zinc 0.00 to 3.00 mg/L (as Zn) 0.01 mg/L ±0.03 mg/L ±3% of reading Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method 575 nm HI93731-01
    Specification Detail
    SKU HI83306-01
    Wavelength Accuracy ±1 nm
    Light Source 5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters
    Spectral Bandwidth 8 nm
    Input Channels 1 pH electrode input and 5 photometer wavelengths
    pH Electrode digital pH electrode (not included)
    Logging Type log on demand with user name and sample ID optional input
    Logging Memory 1000 readings
    Connectivity USB-A host for flash drive micro-USB-B for power and computer connectivity
    GLP calibration data for connected pH electrode
    Display 128 x 64 pixel LCD with backlight
    Battery Type / Life 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
    Power Supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
    Environment 0 to 50.0 °C (32 to 122.0 °F) 0 to 95% RH, non-condensing
    Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8 in.)
    Weight 1.0 kg (2.2 lbs.)
    Photometer/Colorimeter Light Detector silicon photodetector
    Cuvette Type round, 24.6 mm
    Number of Methods 128 max.
    Ordering Information Supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
    Warranty 2 years
    Note *Reagents are not included.

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    HI83306 Environmental Analysis Photometer Instruction Manual
    Download
    Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY