Hanna HI88703-01 EPA Compliant Benchtop Turbidity Meter

$2,224.99

    The Hanna Instruments HI88703 is an EPA compliant benchtop turbidity meter engineered for high-accuracy water quality analysis, providing precise and reliable measurements critical for diverse applications. Its advanced design ensures compliance with stringent regulatory standards, making it an indispensable tool for environmental and laboratory settings.

    Advanced Accuracy: Delivers precise turbidity measurements with a high degree of accuracy.

    Regulatory Compliance: Meets and exceeds EPA Method 180.1 and Standard Methods criteria.

    Versatile Operation: Features both ratio and non-ratio turbidity modes for flexible analysis.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

The Hanna Instruments HI88703 Precision Turbidity Benchtop Meter delivers exceptionally accurate and reliable turbidity measurements, particularly in the critical low-turbidity range. Engineered with a cutting-edge optical system, this instrument ensures long-term stability, minimizes stray light interference, and effectively compensates for color in your samples. Routine calibration using the provided standards keeps the tungsten lamp intensity consistent, while the specialized 25 mm round cuvettes made of optical glass guarantee highly repeatable turbidity results.

Key Features:

  • Dual Measurement Modes: The HI88703 offers both ratio and non-ratio turbidity measurement options. Utilize the ratio mode for a broad range of 0.00 to 4000 NTU, or select the non-ratio mode for precise readings within the 0.00 to 40.0 NTU range.
  • Versatile Turbidity Units: Display turbidity results in Nephelometric Turbidity Units (NTU), European Brewing Convention units (EBC), or Nephelos units, providing flexibility for diverse applications.
  • EPA Compliant: This meter meets and surpasses the stringent requirements of EPA and Standard Methods for turbidity measurements. When operating in EPA mode, all turbidity readings are automatically rounded to fulfill regulatory reporting guidelines.
  • Advanced Calibration: The powerful calibration function of the HI88703 effectively compensates for lamp aging and intensity changes. Perform a two, three, four, or five-point turbidity calibration with the included standards (<0.10, 15.0, 100, 750, and 2000 NTU), or customize calibration points using your own prepared standards.
  • AMCO AEPA-1 Primary Turbidity Standard: The included AMCO AEPA-1 standards are recognized by the USEPA as primary reference materials. These non-toxic, highly stable standards consist of uniform styrene divinylbenzene polymer spheres, offering consistent and reusable performance with a long shelf life.
  • GLP Data Management: Comprehensive Good Laboratory Practice (GLP) functions allow for full traceability of calibration conditions, including detailed logs of calibration points, dates, and times.
  • Data Logging: Store up to 200 measurements in the internal memory for easy recall and review at any time.
  • Effortless Data Transfer: Download logged data to a Windows-compatible PC via the USB port and the HI92000 software for convenient storage and in-depth analysis.
  • Intuitive Tutorial Mode: The unique tutorial mode enhances user experience by providing on-screen explanations and confirmation prompts for various operations and preparations.
  • Contextual Help: A dedicated HELP button offers instant access to clear, on-screen tutorial messages and directions, guiding users quickly and easily through setup and calibration based on the currently viewed setting or option.
  • Backlit Graphic LCD: The clear, backlit graphic LCD display offers a user-friendly interface with easy-to-read plain text messages for optimal comprehension.

Turbidity is a critical parameter for evaluating drinking water quality. While historically considered an aesthetic concern, substantial evidence now confirms that effective turbidity control acts as a robust safeguard against waterborne pathogens. In natural environments, turbidity measurements are essential for assessing general water quality and its suitability for aquatic life. Furthermore, monitoring turbidity is vital in wastewater treatment processes to ensure compliance with regulatory standards. Turbidity is an optical property that describes how light is scattered and absorbed rather than transmitted through a liquid, primarily due to suspended solids. Higher turbidity indicates greater light dispersion, and even the purest liquids will exhibit some degree of light scattering, meaning achieving absolute zero turbidity is practically impossible.

Drinking water treatment facilities that draw water from surface sources like lakes and rivers are mandated by the EPA to continuously monitor and report turbidity levels. EPA Method 180.1 sets forth specific requirements for nephelometers and outlines reporting protocols, including an applicable range of 0-40 NTU, a tungsten lamp light source operating between 2200-3000°K, a maximum light path of 10 cm, and a 90° detector with a spectral peak response between 400 nm and 600 nm. The instrument must also be sensitive enough to detect turbidity differences of 0.02 NTU or less in low turbidity waters.

Reporting Requirements According to EPA Method 180.1:

NTU reading Rounded to nearest
0.0 - 1.0 0.05
1 - 10 0.1
10 - 40 1
40 - 100 5
100 - 400 10
400 - 1000 50
> 1000 100
HI88703 Precision Turbidity Meter Light Diagram

Principle of Operation

The HI88703's optical system accurately measures turbidity by analyzing how a light beam is scattered and transmitted through a sample. Factors like the wavelength of incident light, particle size and shape, refractive index, and color all influence the intensity and pattern of scattered light. This advanced instrument features a tungsten filament lamp, a 90° scattered light detector, and a 180° transmitted light detector to precisely capture these critical interactions.

In ratio turbidimeter mode, the meter's microprocessor employs an intelligent algorithm to calculate the NTU value from the signals received by both detectors. This sophisticated processing corrects for and compensates against color interference, while also minimizing the impact of lamp intensity fluctuations, thus reducing the need for frequent calibration.

For non-ratio turbidity measurements, the NTU value is derived solely from the 90° scattered light detector. While this method offers excellent linearity in the low range, it is more susceptible to variations in lamp intensity. The HI88703's optical design significantly reduces stray light, which is crucial for determining the lower detection limit, enabling highly accurate results even for very low turbidity samples.

AMCO AEPA-1 Turbidity Standards for HI88703

The HI88703-11 AMCO AEPA-1 primary turbidity standards are fundamental for ensuring measurement traceability. These high-quality standards are specifically used for the calibration and verification of your HI88703 turbidity meter, delivering consistent and reliable performance.

Supplied with Certificate of Analysis:

  • Lot number
  • Expiration date
  • Standard value @ 25 °C
  • Reference meter NIST traceable

Provided Storage Containers:

  • Light tight
  • Protects from accidental breakage
    Specification Detail
    SKU HI88703-01
    NTU Ratio Range 0.00 to 9.99, 10.0 to 99.9, 100 to 4000 NTU
    0.0 to 99.9, 100 to 26800 Nephelos
    0.00 to 9.99, 10.0 to 99.9, 100 to 980 EBC
    NTU Ratio Resolution 0.01, 0.1, 1 NTU
    0.1, 1 Nephelos
    0.01, 0.1, 1 EBC
    NTU Non-Ratio Range 0.00 to 9.99, 10.0 to 40.0 NTU
    0.0 to 99.9, 100 to 268 Nephelos
    0.00 to 9.80 EBC
    NTU Non-Ratio Resolution 0.01, 0.1 NTU
    0.1, 1 Nephelos
    0.01 EBC
    NTU Accuracy ±2% of reading plus 0.02 NTU (0.15 Nephelos / 0.01 EBC)
    ±5% of reading above 1000 NTU (6700 Nephelos / 245 EBC)
    Range Selection Automatic
    Turbidity Repeatability ±1% of reading or 0.02 NTU (0.15 Nephelos / 0.01 EBC), whichever is greater
    Stray Light < 0.02 NTU (0.15 Nephelos / 0.01 EBC)
    Turbidity Light Detector Silicon Photocell
    Turbidity Method Nephelometric method (90°) or Ratio Nephelometric Method (90° & 180°)
    Adaptation of USEPA Method 180.1 and Standard Method 2130 B.
    Measuring Mode Normal, Average, Continuous
    Turbidity Standards <0.1, 15, 100, 750, 2000 NTU
    Calibration Two, three, four, or five-point calibration
    Light Source Tungsten filament lamp
    Lamp Life Greater than 100,000 readings
    Display 40 x 70 mm graphic LCD (64 x 128 pixels) with backlight
    LOG Memory 200 records
    Serial Interface USB
    Environment 0°C (32°F) to 50°C (122°F), max 95% RH non-condensing
    Power Supply 230 V/50 Hz or 115 V/60 Hz, 20 W
    Auto Shut-Off After 15 minutes of non-use
    Dimensions 230 x 200 x 145 mm (9 x 7.9 x 5.7 in.)
    Weight 2.5 kg (88 oz.)
    Warranty 2 years

    Shipping, Return, and Warranty Policy

    At Blue Tiger Scientific, we are proud to distribute authentic Hanna Instruments products. The following policies apply to all purchases made through our store.

    Shipping Policy

    • All orders are shipped via FedEx from Hanna Instruments' fulfillment center in Smithfield, Rhode Island.
    • FedEx Ground is the standard method; expedited options (2-Day, Overnight) are available for an additional cost.
    • Hanna Instruments only ships to residential or business addresses within the United States (no PO Boxes).
    • Orders placed after business hours, weekends, or holidays will ship the next business day, pending product and carrier availability.
    • Shipping timelines may vary depending on product availability, order size, and carrier logistics.
    • Blue Tiger Scientific and Hanna Instruments are not responsible for carrier delays, weather-related disruptions, or other unforeseen delivery issues once the order has shipped.

    Return Policy

    • All return requests must be coordinated directly with Blue Tiger Scientific before a product is sent back.
    • Products must have a Return Merchandise Authorization (RMA) number issued by Blue Tiger Scientific before being returned.
    • Products must be returned in new or like-new condition, with the original packaging and proof of purchase (such as an invoice or packing slip).
      Customers are responsible for return shipping costs unless otherwise stated.
    • Unauthorized returns (without an RMA) will be refused and returned at the customer's expense.
      Returns are subject to inspection and approval. Products not in acceptable condition may be denied credit.
    • Some products, such as custom-built, special order, and hazardous materials, may not be eligible for return.

    Warranty Policy

    • Hanna Instruments' products are covered by their Limited Warranty against defects in materials and workmanship under normal use.
    • All warranty claims and services are handled directly by Hanna Instruments.
    • Warranty periods vary by product. If unspecified, the standard warranty term is 18 months from the Hanna Instruments factory ship date.
    • If you experience an issue believed to be covered under warranty, please contact Hanna Instruments for guidance on how to submit your warranty request to Hanna Instruments.
    • Customers must follow Hanna Instruments' warranty submission process, including providing a claim number, product model and serial number, and a detailed description of the issue.
    • Hanna Instruments will determine whether products are repaired, replaced, or otherwise serviced under warranty.
    • Note: Warranty coverage does not apply to damage caused by misuse, accidents, unauthorized repairs, or improper storage and handling.

    Important Notes

    • Some Hanna Instruments products are custom-made or built to order. Shipping will occur once the product is ready.
    • In the event of backorders, you may request partial shipments.
    • Delays beyond our control (e.g., material shortages, import delays, or carrier issues) may occasionally occur.
    HI88703 Precision Turbidity Meter Instruction Manual
    Download
    Manual

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat