Scilogex SCI-2102UV Single-Beam UV-Vis Spectrophotometer, 2 nm Scilogex
Scilogex SCI-5101XUV Double-Beam Spectrophotometer 190-1100nm, 1mm bandwidth Scilogex
Scilogex SCI-5101XUV Double-Beam Spectrophotometer 190-1100nm, 1mm bandwidth Scilogex
Scilogex SCI-5101XUV Double-Beam Spectrophotometer 190-1100nm, 1mm bandwidth Scilogex
Scilogex SCI-2102UV Single-Beam UV-Vis Spectrophotometer, 2 nm Scilogex
Scilogex SCI-5101XUV Double-Beam Spectrophotometer 190-1100nm, 1mm bandwidth Scilogex
Scilogex SCI-5101XUV Double-Beam Spectrophotometer 190-1100nm, 1mm bandwidth Scilogex
Scilogex SCI-5101XUV Double-Beam Spectrophotometer 190-1100nm, 1mm bandwidth Scilogex

Scilogex SCI-2102UV Single-Beam UV-Vis Spectrophotometer, 2 nm

$5,692.00

    Scilogex SCI-2102UV UV-Vis spectrophotometer (MPN 401032010009): single beam, 190–1100 nm and fixed 2 nm bandwidth. A 10.1-inch touchscreen supports stand-alone measurement and scanning. Standard setup includes a manual 10 mm four-cell holder, four glass cuvettes and two quartz cuvettes. Confirm the method’s bandwidth requirement and supplied software/electrical configuration.

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

Preparing Quote Cart. Your shopping cart stays unchanged.

SCILOGEX SCI-2102UV · MPN 401032010009

UV-Vis measurement.
A defined 2 nm setup.

Single-beam measurement across 190–1100 nm, with a fixed 2 nm spectral bandwidth and a 10.1-inch touchscreen.

Choose this configuration when your method accepts 2 nm bandwidth. Set the wavelength, blank the instrument and measure with the cuvette and accessory setup your procedure requires.

Scilogex SCI-2102UV single-beam UV-Vis spectrophotometer, manufacturer photograph, MPN 401032010009

190–1100 nm

Published wavelength range

2 nm

Fixed spectral bandwidth—not 2 mm

10.1-inch

Color capacitive touchscreen

Work from the instrument. Keep the method in charge.

Photometry and scanning

Photometric and quantitative measurement, spectrum scans, kinetics, multi-wavelength measurement and DNA/protein functions are listed by Scilogex. A function name is not a validated assay or proof of sample suitability.

Manual cuvette workflow

The standard holder is a manual four-cell holder for 10 mm cuvettes. Establish the blank/reference reading and measure samples using your documented procedure; four positions do not mean automatic cell changing.

Export for further analysis

The manufacturer lists USB storage/export, USB host and RS232 connections. Test data and working curves can be stored on the instrument; exported data can be processed outside it. Confirm PC-control software separately.

Configure the workflow before ordering

This is a purchasing checklist, not an optical diagram. Work left to right through these three decisions.

01 · Check the method

Confirm that 190–1100 nm covers the required wavelengths and that a fixed 2 nm bandwidth is permitted. If the procedure specifies 1 nm or another bandwidth, do not substitute without validating the change.

02 · Check the cuvettes

Start with the supplied 10 mm manual holder. For UV measurements, use quartz cuvettes within their documented transmission range. Match material, path length, volume and holder fit to the method; glass is not a universal UV substitute.

03 · Check the extras

Identify any need for automatic cell changing, temperature control, micro-cell handling or specialist accessories. Confirm exact compatibility and the supplied PC software/license before adding optional items.

2 nm can be sufficient when the method accepts it.

Bandwidth is the spectral interval passed by the monochromator; it is not the same as wavelength accuracy. Whether 2 nm is appropriate depends on the procedure and spectral features being measured. A narrower bandwidth or double-beam layout is not an automatic guarantee of better results.

Included setup versus optional accessories

Configuration Manufacturer-listed items What to confirm
Standard instrument setup Single-beam SCI-2102UV; deuterium and tungsten/halogen light sources; 10 mm manual four-cell holder. Exact model/MPN and electrical configuration on the order. Lamps are instrument light sources, not a promise of spare lamps.
Standard accessories Four 10 mm glass cuvettes; two 10 mm quartz cuvettes; power cord; user’s manual; PC software. Cuvette condition, supplied software package/license and power cord/plug for your location.
Optional—not included Automatic cell holder; thermostatic automatic sampler; adjustable micro-cell holder; reflection accessory; integrating sphere. Model-specific compatibility and availability. Do not assume all accessories are available for every application.
PC control The page lists PC software among standard accessories but calls Wave Professional optional. Confirm whether the supplied software includes the required PC-control license, supported operating system and connection requirements.

Which Scilogex UV-Vis configuration fits your lab?

All four models cover 190–1100 nm. Choose bandwidth against your method and beam design against your blank/reference workflow. This is a configuration guide, not an accuracy or performance ranking.

Model Beam Design Bandwidth Best-Fit Consideration
SCI-2101UV Single beam 1 nm When sequential blanking suits your workflow and your method calls for 1 nm bandwidth.
SCI-2102UVThis listing Single beam 2 nm When sequential blanking suits your workflow and your method accepts 2 nm bandwidth.
SCI-3101UV Double beam 1 nm When sample/reference measurement suits your workflow and your method calls for 1 nm bandwidth.
SCI-3102UV Double beam 2 nm When sample/reference measurement suits your workflow and your method accepts 2 nm bandwidth.

On a phone, swipe the chart horizontally to compare all four columns. Double beam is not automatically necessary; confirm your method, cuvettes and measurement requirements before selecting.

A few details to confirm before purchase

Performance documents differ

The current product page and SCI-2102UV brochure agree on the published values shown in our specification table. The linked manual differs on some photometric, stray-light, baseline and noise values. Confirm the specifications applicable to the supplied unit if these limits are critical to your method.

Electrical and shipping details

The product page/brochure list AC 110 V/60 Hz or AC 220 V/50 Hz; the manual lists AC 110–230 V/50–60. Shipping dimensions and gross weights also differ across documents. Confirm the unit rating, plug and packed shipment details before installation or freight planning.

Software, coverage and delivery

PC software is listed as standard, while Wave Professional is described as optional. General manufacturer warranty/support pages use differing coverage wording; exact SCI-2102UV coverage is not confirmed here. Availability messages also conflict. Request written confirmation rather than relying on a fixed warranty term or dispatch promise.

Eight questions to settle before purchase

Is this the 2 nm SCI-2102UV configuration?

Yes. This listing is SCI-2102UV, manufacturer part number 401032010009: single beam, 190–1100 nm and fixed 2 nm spectral bandwidth. The older “2 mm” wording is a unit error; bandwidth is measured in nanometres.

Will 2 nm bandwidth be sufficient for my method?

It can be sufficient if the method accepts 2 nm and the required measurement performance is met. Check the written procedure, relevant spectral features and validation criteria. Do not replace a specified 1 nm instrument solely because both cover the same wavelength range.

How is single beam different from double beam?

A single-beam workflow establishes a blank/reference reading before measuring samples. Double-beam instruments use sample/reference paths. SCI-2102UV is single beam; choose the layout your method requires rather than treating beam layout as a universal accuracy ranking.

Which cuvettes and holder come as standard?

Scilogex lists a manual 10 mm four-cell holder, four 10 mm glass cuvettes and two 10 mm quartz cuvettes. Use quartz for UV wavelengths within the cuvette’s stated transmission range. Confirm path length, fill volume, material compatibility and fit for your procedure.

Can it scan spectra and follow kinetics without a computer?

Scilogex describes stand-alone operation through the 10.1-inch touchscreen, with photometric, quantitative, kinetics, spectrum-scan, DNA/protein and multi-wavelength functions. Select and validate the measurement settings for your method; the listed functions are not application-validation claims.

Is Wave Professional PC-control software included?

PC software is listed as a standard accessory, but the same product page describes Wave Professional as optional. Confirm the supplied application, license and supported operating system before planning computer control. USB storage/export is separately listed.

Are automatic sampling or temperature control included?

No. The standard holder is manual. Scilogex lists an automatic cell holder, thermostatic automatic sampler, adjustable micro-cell holder, reflection accessory and integrating sphere as optional. Confirm compatibility and availability for SCI-2102UV before specifying any of them.

How do I order SCI-2102UV, and what should I confirm before delivery?

Confirm the electrical rating and plug for MPN 401032010009, exact warranty coverage, current availability and packed shipping details. The product page, brochure and manual differ on electrical/logistics values, and general warranty/support wording is not model-specific. No fixed delivery date or warranty term is promised here. Order catalog 401032010009 through Add to Cart, or use the existing Add to Quote option for a purchase-order quote or application question. A storefront quantity is not proof of physical supplier stock or immediate dispatch.

Manual and brochure downloads

Download manufacturer brochure (PDF)

SCI-2102UV specifications: PDF page 2.

Download manufacturer operating manual (PDF)

Covers SCI-2101UV, SCI-2102UV, SCI-3101UV and SCI-3102UV.

The manual link is labelled for SCI-2101UV and SCI-3102UV on the manufacturer page, but the document covers all four models, including SCI-2102UV. Use the correct model column.

    SCI-2102UV specifications · current product page and model-specific brochure

    SpecificationSCI-2102UV
    Model / manufacturer part numberSCI-2102UV / 401032010009
    Optical systemSingle beam; grating 1200 lines/mm
    Wavelength range190–1100 nm
    Spectral bandwidth2 nm (fixed)
    Wavelength accuracy±0.1 nm at 656.1 nm; ±0.3 nm across the range
    Wavelength repeatability≤0.1 nm
    Photometric accuracy0.2%T (0–100%T); ±0.002 A (0–0.5 A); ±0.004 A (0.5–1 A)
    Photometric repeatability≤0.15%T (0–100%T); 0.001 A (0–0.5 A); 0.002 A (0.5–1 A)
    Photometric range0–200%T; −0.3 to 3 A; 0–9999 C (0–9999 F)
    Stray light≤0.03%T at 220 nm and 360 nm
    Stability±0.0003 A/h at 500 nm
    Baseline flatness±0.001 A
    Noise0.0005 A at 500 nm
    Work modesT, A, C, E
    Scanning speedHigh, medium, low; maximum 3000 nm/min
    Wavelength settingAutomatic
    Display10.1-inch TFT color capacitive touchscreen; 1024 × 600
    Light sourcesDeuterium and tungsten lamps (product title: halogen)
    DetectorSilicon photodiode
    Cuvette holder10 mm manual four-cell holder
    Output / interfacesUSB drive, USB host, RS232
    Power, page / brochure listingAC 110 V / 60 Hz or AC 220 V / 50 Hz; confirm supplied unit rating and plug
    Standard accessoriesFour 10 mm glass cuvettes; two 10 mm quartz cuvettes; power cord; user’s manual; PC software (package/license to be confirmed)

    Source note: the linked operating manual publishes differing photometric, stray-light, baseline, noise and electrical values. Confirm applicable unit specifications where these limits govern your method. Dimensions and gross shipping weight are omitted pending reconciliation of the conflicting documents.

    Purchasing Scilogex through Blue Tiger Scientific

    Blue Tiger Scientific is an authorized Scilogex reseller. We are your point of contact for your order, purchase documents, return requests and coordination with the manufacturer. Scilogex provides and administers the applicable manufacturer warranty and factory service. Blue Tiger Scientific does not manufacture these products or provide an additional manufacturer warranty.

    Orders, fulfillment and purchase terms

    Your order is placed with Blue Tiger Scientific and is subject to the purchase terms presented by our store. Scilogex’s applicable product, return and warranty requirements govern manufacturer approval and service. Confirm the exact catalog number, electrical configuration, included items, optional accessories and any software license before ordering. Supplier-fulfilled availability and delivery estimates must be confirmed for your order; a storefront quantity is not proof of physical stock or immediate dispatch.

    Returns must start with Blue Tiger Scientific

    Contact info@bluetigerscientific.com or call 833-928-4437 before returning a Scilogex product purchased from us. Provide your Blue Tiger order number, catalog/model number, serial number where applicable and the reason for your request. We will coordinate the request with Scilogex and provide the authorized return number and shipping instructions if approved. Do not ship to Blue Tiger Scientific or Scilogex without our written instructions. Requesting a return does not by itself authorize shipment or guarantee credit.

    Standard return eligibility

    Scilogex’s published standard return policy requires eligible returns within 14 days of the purchase date. Contact Blue Tiger Scientific promptly so we can coordinate authorization and shipping within the applicable window. Standard returns must be new and unused, with original tags and labels. Keep the original packaging, proof of purchase and supplied items. Missing packaging or items, requests outside the standard window and other exceptions require Scilogex review; restocking charges may apply. Any extension beyond the standard window requires written Scilogex approval coordinated through Blue Tiger Scientific. An exception is not guaranteed.

    Return shipping, safety and inspection

    Follow the approved packing, tracking and insurance instructions. Scilogex’s standard policy makes the customer responsible for return shipping charges; any different handling for a defect or damage claim must be confirmed in writing. Manufacturer-required decontamination documentation must be completed, and contaminated equipment must not be returned without appropriate clearance and instructions. Insure the shipment at the required value. Return eligibility and the remedy are subject to Scilogex inspection and approval.

    Defective or damaged equipment

    Notify Blue Tiger Scientific promptly and provide a description, photographs where useful, and the product’s identifying details. Retain the packaging. We will coordinate the appropriate next steps with Scilogex. Do not make unauthorized repairs or send the instrument back before receiving instructions. A damage or defect report is separate from an ordinary change-of-mind return and does not automatically establish a refund entitlement.

    Manufacturer warranty and service

    Scilogex determines whether a claim is covered and authorizes the applicable repair, replacement or other remedy under its warranty. Confirm the written warranty duration and any lamp, consumable or model-specific exclusions for the exact product before purchase. General category-level warranty wording does not override a product-specific warranty. Misuse, improper installation, unauthorized repairs, physical or chemical abuse, and use contrary to the supplied instructions can affect coverage. Keep your invoice and contact Blue Tiger Scientific to coordinate a claim; manufacturer-approved technical support or service is performed by Scilogex or its authorized service provider.

    Warranty registration

    After delivery, complete Scilogex’s warranty registration as instructed by the manufacturer and retain your proof of purchase, model and serial number. Scilogex describes registration as activating coverage, supporting access to product assistance and enabling recall contact. Blue Tiger Scientific can help you obtain the registration instructions. Registration does not expand the applicable warranty or substitute for its conditions.

    Refunds and account credits

    Any approved refund, credit or exchange for a purchase through Blue Tiger Scientific will be coordinated through us following the applicable inspection and approval process. Scilogex publishes a return-processing estimate of 7–10 days after receipt; this is not a guaranteed Blue Tiger refund date. Additional payment-provider processing time may apply. We will confirm the outcome and any applicable authorized deductions rather than promising an automatic refund.

    These statements summarize our reseller process and relevant manufacturer requirements. They do not replace the applicable written product warranty, your confirmed order terms or rights that cannot be limited under applicable law.

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat