Skip to content
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments
Milwaukee MI415 PRO Portable Turbidity Meter Milwaukee Instruments

Milwaukee MI415 PRO Portable Turbidity Meter

$1,104.60

    SKU: MI415

    UPC: 810666000517

    MPN: MI415

    Range: 0.00 to 50.00 (FNU) | 50 to 1000 (FNU)

    Resolution: 0.01 (FNU) | 1 (FNU)

    Accuracy: ±0.5 (FNU) or 5% reading (whichever is greater)

    Manual: Milwaukee MI415 Manual

See All Specs

aeroplane.png__PID:119d4b1a-2623-400c-8fa4-aec5b49a3bf0

Fast Delivery

Most items ship same day

protection.png__PID:4b1a2623-e00c-4fa4-aec5-b49a3bf05f92

Manufacturer Warranty

All products are covered by manufacturer warranty

technical-support.png__PID:e00c8fa4-aec5-449a-bbf0-5f923431936b

After-Sale Support

24/7 support

What's Included

download (70).webp__PID:7ab0a366-c50a-41ee-ae3a-ab9ed2dfc0ad

VR Headset

download (71).webp__PID:547ab0a3-66c5-4a41-aeae-3aab9ed2dfc0

2 Touch Controllers

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Charging Cable

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Power Adapter

download (72).webp__PID:dc547ab0-a366-450a-81ee-ae3aab9ed2df

Glasses Spacer

download (69).webp__PID:26576cae-f878-4c99-ab7c-894d76af129b

Lab Grade, Easy to Use, High Performance.

Milwaukee MI415 PRO Turbidity Meter is for users demanding fast, reliable, repeatable results with ease of use.

Description

The Milwaukee MI415 PRO Turbidity features easy 3 point FNU calibration. The calibration points are 0, 10 and 500 FNU (Formazine Neophelmetric Unit). Calibration is automatic and fast with easy operation and a rugged meter design.

The Milwaukee MI415 PRO Turbidity Meter is ideal for users in aquaculture, waste and drinking water treatment, environmental labs and many other applications. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.

The Milwaukee PRO MI415 Turbidity Meter offers:

Speed & Accuracy

The MI415 microprocessor delivers fast results with accuracy of ±5 FNU or 5% of the reading (whichever is greater) and is repeatable.

Easy To Use and Toughness

This rugged meter is designed to take knocks. It's low maintenance design paired with easy to use reagents makes the MI415 ideal for everyone from educators and aquaculture, brewers, environmental professionals to water treatment and food processing.

Design features

  • Fast easy to read results with large digital LCD readout.
  • Accurate to ±0.5 FNU or 5% of reading (whichever is greater).
  • Lightweight and portable.
  • Tungsten Lamp for high accuracy.
  • The unit of measure adopted by the ISO Standard is the FNU (Formazine Nephelometric
    Unit) and by EPA is NTU (Nephelometric Turbidity Unit).
  • Easy measurement: just fill a cuvette with the sample after calibration, insert the cuvette, then press read and the reading displays on the large LCD.
  • Simple easy-to-use calibration cuvettes.
  • Easy 1-2-3 instruction steps.
  • Auto shut off after 5 minutes of non-use, 9 volt (battery included).
  • Replacement Reagents: Mi515-100.

Built In Timer

MI415 PRO Turbidity Meter has a built in timer that ensures appropriate reaction time is used for the chemical reaction. At the end of the timer, the meter will automatically take the reading. This feature ensures consistency across multiple users.

Cuvette Chamber

The MI415 has a built in indexing indent on the meter - The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.

Error Messaging

The MI415 has built in error messaging display alerts. This helps the user ensure no mistakes are made in the testing process. Messages include no cap, over range and under range, light source errors and zero cal error to ensure the user has the most accurate error free readings.

Calibration

The MI415 has a simple to use 3 point (FNU) calibration at 0, 10 and 500 (FNU). Simply insert the standard sample cuvette into the chamber, index the cuvette and follow the 3 steps. Your calibration is complete.

    Specification Detail
    Turbidity Range: 0.00 to 50.00 (FNU) | 50 to 1000 (FNU)
    Resolution: 0.01 (FNU) | 1 (FNU)
    Accuracy: ±0.5 (FNU) or 5% of reading (whichever is greater)
    Method: Detection of scattered light
    Light Source: High Emission Infrared LED
    Light Detector: Silicon photocell
    Operating Environment: 0 to 50 °C (32 to 122 ¡ F) / Max. RH 100%
    Battery Type: 1 X 9V (included)
    Auto-off: after 8 minutes of non-use
    Mi515-100 calibration standards 0, 10 and 500 FNU (included)
    Meter Dimensions: 7.56 x 4.09 x 2.04 inches (192 x 104 x 52 mm)
    Meter Weight: .84 lbs. (0.38 kg)
    Packaging Dimensions: 12 x 11 x 4.53 inches (305 x 280 x 115 mm)
    Packaged Weight: 2.73 lbs. (1.24 kg)
    Glass Cuvettes: MI0011 ( 2 x included)

    Milwaukee Instruments Warranty & Returns Policy
    (For Milwaukee Instruments ONLY – Not for Milwaukee Tools)

    How to Initiate a Return or Warranty Claim
    For products purchased through Blue Tiger Scientific, all returns must be initiated directly with us. However, all warranty claims must be handled directly through Milwaukee Instruments.

    Warranty Information
    Milwaukee Instruments products are manufactured to meet the highest quality standards and come with a limited warranty against defects in materials and workmanship. Products may be returned for repair or replacement at Milwaukee's discretion. Warranty is void if the product has been abused, misused, or repaired by unauthorized persons.

    To register your Milwaukee product, click here.

    Warranty Periods

    • Handheld testers, portable meters, and stationary monitors/controllers: 2 years
    • Bench meters: 3 years
    • PH600 pH Pen and similar versions: 1 year
    • Replaceable probes: 6 months

    Warranty begins on the original end-user purchase date or a maximum of 12 months from dealer purchase. Valid only with proper usage and maintenance. Service occurs at Milwaukee Instruments' North Carolina Technical Service Center.

    Note: Meters used in Kangen Water or “Negative ORP Water” applications are excluded from warranty coverage. Any warranty for these uses is null and void.

    Filing a Warranty Claim
    Contact Milwaukee Instruments Customer Service at (252) 443-3630 EST for an RMA number. Mark the RMA clearly on the box and ship prepaid. Improper packing can void the warranty.

    Return Policy (Blue Tiger Scientific)
    All purchases are final, but returns may be accepted under specific conditions:

    • Items must be in new condition with original packaging and contents.
    • Returns must be initiated within 14 days of purchase.
    • Subject to up to 30% restocking fee.
    • Customer pays all return shipping.
    • Initial shipping charges are non-refundable.

    Returns will be refused if packaging is damaged or contents are missing.

    Initiating a Return with Blue Tiger Scientific
    Contact Blue Tiger Scientific for an RMA and shipping instructions. Mark RMA clearly and pack securely to avoid transit damage. Shipping damage claims are the sender’s responsibility.

    Refunds, if eligible, will be processed within 5–10 business days. Credit card refunds may take longer to appear on your statement.

Product Resources:

Copy of Technical Specifications

FeatureDetails
Viewing Head Siedentopf type trinocular head, inclined at 30°, Interpupillary adjustment 53mm to 75mm, graduated diopter on left eyetube (30mm I.D. eyetubes)
Eyepieces SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
Nosepiece Quintuple
Quintuple LWD Planachromat Phase 10x, 20x
Condenser TC Condenser N.A. 0.30, W.D. 73.0mm
Stage180mm(X) x 245mm(Y) plain stage with replaceable glass insert with 45mm opening, Glass Stage plate insert
IlluminationKoehler without iris, with phase slider, 3W LED
WarrantyLIMITED LIFETIME WARRANTY

Questions about a product? Ask us here.

email us here: info@bluetigerscientific.com or live chat